Permit: T21CM09877
Permit Details
Status:
Issued
Type:
Residential Building - One or Two Family
Address:
6334 S CRESCENT PEAK DR
Address NEW:
6334 S CRESCENT PEAK DR
Apply Date:
12/27/2021
Applicant:
Russ Salmon
Description:
SFR LENNVC354 T20-M0030
Outstanding Activity Conditions
Permit Number - T21CM09877
Permit Status: Issued
Permit Description: SFR LENNVC354 T20-M0030
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 12/27/2021 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Conditions
Permit Number - T21CM09877
Permit Status: Issued
Permit Description: SFR LENNVC354 T20-M0030
| Date | Description | Comments |
|---|---|---|
| 12/27/2021 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. |
Completed Inspections
Permit Status: Issued
Permit Number: T21CM09877
Permit Description: SFR LENNVC354 T20-M0030
Total Completed Inspections - 24
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/15/2022 | COT - RSPL - Yard Water Line | Passed | {Activity date: 02/15/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - AP} | |
| 02/15/2022 | COT - RSPL - Sewer | Passed | {Activity date: 02/15/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - AP} | |
| 02/15/2022 | COT - RSPL - Rough Soil | Passed | {Activity date: 02/15/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - AP} | |
| 03/02/2022 | COT - RSEL - Grounding/Bonding | Passed | {Activity date: 03/02/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - AP} | |
| 03/02/2022 | COT - RSBU - Preslab | Passed | {Activity date: 03/02/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - AP} ; {Activity date: 03/01/2022; Status: Not ready for Inspection; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - NR Cancel all other inspections} |
|
| 03/02/2022 | COT - RSEL - Electrical Underground | Passed | {Activity date: 03/02/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - AP} | |
| 03/02/2022 | COT - RSBU - Excavation/Rebar/Zoning | Passed | {Activity date: 03/02/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - AP} | |
| 03/31/2022 | COT - RSBU - Roof Nailing | Passed | {Activity date: 03/31/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP} ; {Activity date: 03/21/2022; Status: Not ready for Inspection; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - NR} | |
| 04/13/2022 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | {Activity date: 04/13/2022; Status: Approved; Inspector: ESTEVENS; Comment: Entered by VVERA1 - Approved} ; {Activity date: 03/31/2022; Status: Correction Required; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - CO Remove all nails from top plates into bottom cords of trusses and install slip clips.} ; {Activity date: 03/21/2022; Status: Correction Required; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - CO 1. Remove all shims & H2.5 clips at interior truss bearing points. 2. Remove all nails from ladder blocking into top of walls and install slip-clips. 3. Provide truss calcs.} |
|
| 05/18/2022 | PDSD Building Division - TEP PM Clearance | Passed | {Activity date: 05/18/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - CODE ECO} | |
| 05/18/2022 | COT - RSEL - Construction Power | Passed | {Activity date: 05/18/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - AP TEP ECO } |
|
| 06/27/2022 | RSME - Mechanical Progress | Passed | {Activity date: 06/27/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - AP} | |
| 06/27/2022 | COT - RSPL - Gas Pressure Test | Passed | {Activity date: 06/27/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - AP} | |
| 07/05/2022 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | {Activity date: 07/05/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP} ; {Activity date: 06/27/2022; Status: Correction Required; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - CO 1. Shim mid-bearing point of trusses in garage. 2. Replace all over-notched bearing wall studs 3. Ufer not set correctly at acorn clamp 4. Move PEX away from B-vent 5. Repair large hole in roof around B-vent} |
|
| 07/05/2022 | COT - LCBU - Framing | Passed | {Activity date: 07/05/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP} ; {Activity date: 06/27/2022; Status: Correction Required; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - CO} | |
| 07/05/2022 | COT - LCPL - Plumbing Intermediate | Passed | {Activity date: 07/05/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP} ; {Activity date: 06/27/2022; Status: Correction Required; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - CO} | |
| 07/05/2022 | RSEL - Electrical Progress | Passed | {Activity date: 07/05/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP} ; {Activity date: 06/27/2022; Status: Correction Required; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - CO} | |
| 07/20/2022 | COT - HCBU - Interior Shear Bracing | Passed | {Activity date: 07/20/2022; Status: Approved; Inspector: DMUNIZ; Comment: Entered by VVERA1 - Approved} | |
| 09/07/2022 | COT - BULD - SWG Clearance | Passed | {Activity date: 09/07/2022; Status: Approved; Inspector: SCARRAZCO; Comment: Entered by VVERA1 - CODE} | |
| 09/23/2022 | COT - RSME - Mechanical Final | Passed | {Activity date: 09/23/2022; Status: Approved; Inspector: SCARRAZCO; Comment: Entered by NGARCIA3 - Approved} | |
| 09/28/2022 | RSBU - Building Final | Passed | {Activity date: 09/28/2022; Status: Approved; Inspector: KEN; Comment: Entered by KKARSEN1 - Truss Plan released} ; {Activity date: 09/28/2022; Status: Partial Approval; Inspector: SCARRAZCO; Comment: Entered by VVERA1 - APPROVED BY INSPECTOR AWAITING CONDITIONS } ; {Activity date: 09/28/2022; Status: Approved; Inspector: SCARRAZCO; Comment: Entered by VVERA1 - Approved} ; {Activity date: 09/23/2022; Status: Not ready for Inspection; Inspector: SCARRAZCO; Comment: Entered by NGARCIA3 - Not ready. Garage door needs to be adjusted for self latching.} |
|
| 09/28/2022 | COT - RSEL - Outdoor Lighting | Passed | {Activity date: 09/28/2022; Status: Approved; Inspector: SCARRAZCO; Comment: Entered by VVERA1 - 1090.Approved} | |
| 09/28/2022 | COT - RSPL - Plumbing Final | Passed | {Activity date: 09/28/2022; Status: Approved; Inspector: SCARRAZCO; Comment: Entered by VVERA1 - Approved} ; {Activity date: 09/23/2022; Status: Not ready for Inspection; Inspector: SCARRAZCO; Comment: Entered by NGARCIA3 - Not ready. Cut minimum 6” from grade on drainage lines.} ; {Activity date: 09/07/2022; Status: Partial Approval; Inspector: SCARRAZCO; Comment: Entered by VVERA1 - partial. Clearance for southwest gas.} | |
| 09/28/2022 | COT - RSEL - Electrical Final | Passed | {Activity date: 09/28/2022; Status: Approved; Inspector: SCARRAZCO; Comment: Entered by VVERA1 - Approved} ; {Activity date: 09/23/2022; Status: Not ready for Inspection; Inspector: SCARRAZCO; Comment: Entered by NGARCIA3 - Not ready. Lines coming out underneath kitchen sink. Missing cap for receptacle. A/c shut off needs to be moved over. Half hot receptacle needs correction. Receptacle in garage needs to be fixed due to broken prong.} |