Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Issued
Type:
Residential Building - One or Two Family
Apply Date:
12/16/2021
Applicant:
Andrea Flood
Description:
SFR F50A19 T19-M0034

Outstanding Activity Conditions

Permit Number - T21CM09625
Permit Status: Issued
Permit Description: SFR F50A19 T19-M0034
Total Outstanding Activity Conditions - 1
Date Name
12/16/2021 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Issued
Permit Number: T21CM09625
Permit Description: SFR F50A19 T19-M0034
Total Completed Inspections - 17
Date Description Inspector Results Comments
02/24/2022 COT - RSPL - Yard Water Line Passed {Activity date: 02/24/2022; Status: Approved; Inspector: WGALLAGHER; Comment: Entered by VVERA1 - Approved}
02/24/2022 COT - RSPL - Sewer Passed {Activity date: 02/24/2022; Status: Approved; Inspector: WGALLAGHER; Comment: Entered by VVERA1 - Approved}
02/24/2022 COT - RSPL - Rough Soil Passed {Activity date: 02/24/2022; Status: Approved; Inspector: WGALLAGHER; Comment: Entered by VVERA1 - Approved}
03/03/2022 COT - RSEL - Grounding/Bonding Passed {Activity date: 03/03/2022; Status: Approved; Inspector: WGALLAGHER; Comment: Entered by NGARCIA3 - Approved}
03/03/2022 COT - RSBU - Preslab Passed {Activity date: 03/03/2022; Status: Approved; Inspector: WGALLAGHER; Comment: Entered by NGARCIA3 - Approved}
03/03/2022 COT - RSEL - Electrical Underground Passed {Activity date: 03/03/2022; Status: Approved; Inspector: WGALLAGHER; Comment: Entered by NGARCIA3 - Approved}
03/03/2022 COT - RSBU - Excavation/Rebar/Zoning Passed {Activity date: 03/03/2022; Status: Approved; Inspector: WGALLAGHER; Comment: Entered by NGARCIA3 - Approved}
04/21/2022 COT - RSBU - Roof Nailing Passed {Activity date: 04/21/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP} ; {Activity date: 04/19/2022; Status: Cancelled; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - CA}
04/26/2022 COT - RSBU - Exterior Clips/Sheathing Passed {Activity date: 04/26/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP} ; {Activity date: 04/21/2022; Status: Correction Required; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - CO
1. Incorrect window framing at north west corner
2. Loose shear panel at interior wall south of kitchen
3. RFI for (4) ES} ; {Activity date: 04/19/2022; Status: Cancelled; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - CA per Scott}
07/29/2022 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed {Activity date: 07/29/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP}
07/29/2022 COT - LCBU - Framing Passed {Activity date: 07/29/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP}
07/29/2022 COT - RSPL - Plumbing Final Passed {Activity date: 07/29/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP}
07/29/2022 RSME - Mechanical Progress Passed {Activity date: 07/29/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP}
07/29/2022 COT - RSPL - Gas Pressure Test Passed {Activity date: 07/29/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP}
08/09/2022 COT - HCBU - Interior Shear Bracing Passed {Activity date: 08/09/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP} ; {Activity date: 08/08/2022; Status: Denied; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - DE
Sheer walls incomplete, maintain min 3/8” from edge of rock with fasteners}
09/19/2022 PDSD Building Division - TEP PM Clearance Passed {Activity date: 09/19/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - CODE ECO}
09/19/2022 COT - RSEL - Construction Power Passed {Activity date: 09/19/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - AP
TEP ECO}

Documents

File Name Document Type  
APPLICATION.PDF DOCUMENTS VIEW
JOB CARD.PDF DOCUMENTS VIEW
PERMIT.PDF DOCUMENTS VIEW
SIC.PDF DOCUMENTS VIEW
SITEPLAN.PDF DOCUMENTS VIEW