Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Issued
Type:
Residential Building - One or Two Family
Apply Date:
12/13/2021
Applicant:
Cindy Nemo
Description:
NEW SFR MODEL RICHT914 T19-M0082

Conditions

Permit Number - T21CM09515
Permit Status: Issued
Permit Description: NEW SFR MODEL RICHT914 T19-M0082
Date Description Comments
12/13/2021 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.
12/13/2021 ROOF TRUSSES MUST BE APPROVED PRIOR TO FRAMING INSPECTION (P2I)

Outstanding Inspections

Permit Status: Issued
Permit Number: T21CM09515
Permite Description: NEW SFR MODEL RICHT914 T19-M0082
Total Outstanding Inspections - 5
Last Inspection Date Description Inspector Results Comments
10/27/2022 COT - RSME - Mechanical Final N/A Not Ready
10/27/2022 RSBU - Building Final N/A Not Ready
10/27/2022 COT - RSEL - Outdoor Lighting N/A Not Ready
10/27/2022 COT - RSEL - Electrical Final N/A Not Ready
10/27/2022 COT - RSPL - Plumbing Final N/A Not Ready

Completed Inspections

Permit Status: Issued
Permit Number: T21CM09515
Permit Description: NEW SFR MODEL RICHT914 T19-M0082
Total Completed Inspections - 19
Date Description Inspector Results Comments
01/12/2022 COT - RSPL - Yard Water Line Passed {Activity date: 01/12/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by RSALDAT1 - AP}
01/12/2022 COT - RSPL - Sewer Passed {Activity date: 01/12/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by RSALDAT1 - AP}
01/12/2022 COT - RSPL - Rough Soil Passed {Activity date: 01/12/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by RSALDAT1 - AP}
02/02/2022 COT - RSEL - Grounding/Bonding Passed {Activity date: 02/02/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP}
02/02/2022 COT - RSBU - Preslab Passed {Activity date: 02/02/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP}
02/02/2022 COT - RSEL - Electrical Underground Passed {Activity date: 02/02/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP}
02/02/2022 COT - RSBU - Excavation/Rebar/Zoning Passed {Activity date: 02/02/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP}
02/24/2022 COT - RSBU - Roof Nailing Passed {Activity date: 02/24/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - AP} ; {Activity date: 02/15/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by RSALDAT1 - AP}
02/24/2022 COT - RSBU - Exterior Clips/Sheathing Passed {Activity date: 02/24/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - AP} ; {Activity date: 02/15/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - P} ; {Activity date: 02/15/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by RSALDAT1 - AP}
07/25/2022 COT - LCBU - Framing Passed {Activity date: 07/25/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - AP} ; {Activity date: 07/19/2022; Status: Cancelled; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - Cancel all inspections per Sean Draper}
07/27/2022 RSME - Mechanical Progress Passed {Activity date: 07/27/2022; Status: Approved; Inspector: SCARRAZCO; Comment: Entered by VVERA1 - approved. Support register on three sides.
} ; {Activity date: 07/25/2022; Status: Correction Required; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - CO} ; {Activity date: 07/19/2022; Status: Cancelled; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - Cancel all inspections per Sean Draper}
07/27/2022 COT - RSPL - Gas Pressure Test Passed {Activity date: 07/27/2022; Status: Approved; Inspector: SCARRAZCO; Comment: Entered by VVERA1 - approved} ; {Activity date: 07/25/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - AP} ; {Activity date: 07/19/2022; Status: Cancelled; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - Cancel all inspections per Sean Draper}
07/29/2022 PDSD Building Division - TEP PM Clearance Passed {Activity date: 07/29/2022; Status: Approved; Inspector: DMUNIZ; Comment: Entered by NGARCIA3 - CODE ECO}
07/29/2022 COT - LCPL - Plumbing Intermediate Passed {Activity date: 07/29/2022; Status: Approved; Inspector: DMUNIZ; Comment: Entered by NGARCIA3 - APPROVED} ; {Activity date: 07/27/2022; Status: Partial Approval; Inspector: SCARRAZCO; Comment: Entered by VVERA1 - partial. Correction required. Provide fire caulk at gas lines.
} ; {Activity date: 07/25/2022; Status: Correction Required; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - CO} ; {Activity date: 07/19/2022; Status: Cancelled; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - Cancel all inspections per Sean Draper}
07/29/2022 COT - RSEL - Construction Power Passed {Activity date: 07/29/2022; Status: Approved; Inspector: DMUNIZ; Comment: Entered by NGARCIA3 - Approved, Clear TEP ECO
} ; {Activity date: 07/27/2022; Status: Not ready for Inspection; Inspector: SCARRAZCO; Comment: Entered by VVERA1 - not ready. Need service entrance cables.} ; {Activity date: 07/27/2022; Status: Not ready for Inspection; Inspector: SCARRAZCO; Comment: Entered by VVERA1 - not ready. Need service entrance cables.} ; {Activity date: 07/25/2022; Status: Not ready for Inspection; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - NR} ; {Activity date: 07/19/2022; Status: Cancelled; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - Cancel all inspections per Sean Draper}
08/02/2022 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed {Activity date: 08/02/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP} ; {Activity date: 07/29/2022; Status: Correction Required; Inspector: DMUNIZ; Comment: Entered by NGARCIA3 - corrections required, finish electrical install @stairwell} ; {Activity date: 07/27/2022; Status: Partial Approval; Inspector: SCARRAZCO; Comment: Entered by VVERA1 - partial. Correction required. Provide DWV test on second floor. All penetrations need to be fire caulked. Electrical cables need to be stapled. Also smoke detector in master bedroom needs to be made up.} ; {Activity date: 07/25/2022; Status: Denied; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - DE.
1. Block high vent in garage
2. Strap ABS in the kitchen
3. Vents are dry on the 2nd floor
4 maintain a min 10 feet separation between vent and fresh air intake
5. Remove unused line set from attic
6. Romex pulled out of smoke det box} ; {Activity date: 07/19/2022; Status: Cancelled; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - Cancel all inspections per Sean Draper}
08/25/2022 COT - HCBU - Interior Shear Bracing Passed {Activity date: 08/25/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP} ; {Activity date: 08/24/2022; Status: Denied; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - DE
Missing screws/nails thruout, screws countersunk, shear wall nailing not per schedule.} ; {Activity date: 08/19/2022; Status: Denied; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - DE
Maintain min 3/8” from edge of sheetrock, do not tear surface paper, do not counter sink screws

}
10/10/2022 COT - BULD - SWG Clearance Passed {Activity date: 10/10/2022; Status: Approved; Inspector: SCARRAZCO; Comment: Entered by VVERA1 - CODE}
10/10/2022 RSPL - Plumbing Progress Passed {Activity date: 10/10/2022; Status: Approved; Inspector: SCARRAZCO; Comment: Entered by VVERA1 - Approved}

Documents

File Name Document Type  
APPLICATION.PDF DOCUMENTS VIEW
C OF O.DOC DOCUMENTS VIEW
JOB CARD.PDF DOCUMENTS VIEW
PERMIT.PDF DOCUMENTS VIEW
SIC.PDF DOCUMENTS VIEW
SITE PLAN.PDF DOCUMENTS VIEW