Permit: T21CM09383
Permit Details
Status:
Issued
Type:
Residential Building - One or Two Family
Address:
6326 S CRESCENT PEAK DR
Address NEW:
6326 S CRESCENT PEAK DR
Apply Date:
12/07/2021
Applicant:
Description:
SFR LENNVC352 T20-M0029
Outstanding Activity Conditions
Permit Number - T21CM09383
Permit Status: Issued
Permit Description: SFR LENNVC352 T20-M0029
Total Outstanding Activity Conditions - 3
| Date | Name |
|---|---|
| 12/07/2021 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
| 12/07/2021 | ROOF TRUSSES MUST BE APPROVED PRIOR TO FRAMING INSPECTION (P2I) |
| 12/07/2021 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. |
Completed Inspections
Permit Status: Issued
Permit Number: T21CM09383
Permit Description: SFR LENNVC352 T20-M0029
Total Completed Inspections - 23
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/18/2022 | COT - RSPL - Yard Water Line | Passed | {Activity date: 01/18/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - AP} | |
| 01/18/2022 | COT - RSPL - Sewer | Passed | {Activity date: 01/18/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - AP} | |
| 01/18/2022 | COT - RSPL - Rough Soil | Passed | {Activity date: 01/18/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - AP} | |
| 02/09/2022 | COT - RSEL - Grounding/Bonding | Passed | {Activity date: 02/09/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by RSALDAT1 - AP} | |
| 02/09/2022 | COT - RSBU - Preslab | Passed | {Activity date: 02/09/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by RSALDAT1 - AP} | |
| 02/09/2022 | COT - RSEL - Electrical Underground | Passed | {Activity date: 02/09/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by RSALDAT1 - AP} | |
| 02/09/2022 | COT - RSBU - Excavation/Rebar/Zoning | Passed | {Activity date: 02/09/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by RSALDAT1 - AP} | |
| 03/04/2022 | COT - RSBU - Roof Nailing | Passed | {Activity date: 03/04/2022; Status: Approved; Inspector: DMUNIZ; Comment: Entered by VVERA1 - Approved} | |
| 03/04/2022 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | {Activity date: 03/04/2022; Status: Approved; Inspector: DMUNIZ; Comment: Entered by VVERA1 - Approved} | |
| 05/17/2022 | PDSD Building Division - TEP PM Clearance | Passed | {Activity date: 05/17/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - CODE ECO} | |
| 05/17/2022 | COT - RSEL - Construction Power | Passed | {Activity date: 05/17/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP TEP ECO} |
|
| 06/10/2022 | RSME - Mechanical Progress | Passed | {Activity date: 06/10/2022; Status: Approved; Inspector: DMUNIZ; Comment: Entered by VVERA1 - Approved} | |
| 06/10/2022 | COT - RSPL - Gas Pressure Test | Passed | {Activity date: 06/10/2022; Status: Approved; Inspector: DMUNIZ; Comment: Entered by VVERA1 - Approved} | |
| 06/13/2022 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | {Activity date: 06/13/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - AP} ; {Activity date: 06/10/2022; Status: Correction Required; Inspector: DMUNIZ; Comment: Entered by VVERA1 - corrections required.} | |
| 06/13/2022 | COT - LCPL - Plumbing Intermediate | Passed | {Activity date: 06/13/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - AP} ; {Activity date: 06/10/2022; Status: Correction Required; Inspector: DMUNIZ; Comment: Entered by VVERA1 - corrections required, master bath San-T @ vent for water closet installed incorrect.} | |
| 06/30/2022 | COT - HCBU - Interior Shear Bracing | Passed | {Activity date: 06/30/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP} | |
| 08/19/2022 | COT - BULD - SWG Clearance | Passed | {Activity date: 08/19/2022; Status: Approved; Inspector: SCARRAZCO; Comment: Entered by VVERA1 - CODE} | |
| 08/29/2022 | COT - RSME - Mechanical Final | Passed | {Activity date: 08/29/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP} | |
| 08/29/2022 | COT - LCBU - Framing | Passed | {Activity date: 08/29/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP} ; {Activity date: 06/10/2022; Status: Correction Required; Inspector: DMUNIZ; Comment: Entered by VVERA1 - corrections required, install nail plates at all plumbing locations D,W,V } |
|
| 08/29/2022 | RSBU - Building Final | Passed | {Activity date: 08/29/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP} | |
| 08/29/2022 | COT - RSEL - Outdoor Lighting | Passed | {Activity date: 08/29/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP} | |
| 08/29/2022 | COT - RSPL - Plumbing Final | Passed | {Activity date: 08/29/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP} ; {Activity date: 08/19/2022; Status: Partial Approval; Inspector: SCARRAZCO; Comment: Entered by VVERA1 - partial. Clearance for southwest gas.} | |
| 08/29/2022 | COT - RSEL - Electrical Final | Passed | {Activity date: 08/29/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP} |