Permit Details

Status:
Issued
Type:
Commercial Building
Apply Date:
12/01/2021
Applicant:
Description:
We are filling in the gap in the center between the newly relocated/replace Family Dollar Store whic

Permit Reviews

Permit Number - T21CM09272
Permit Status: Issued
Permit Description: We are filling in the gap in the center between the newly relocated/replace Family Dollar Store whic
Start Date Submittal Complete Date Status  
12/01/2021 COMMERCIAL - BLDG/FIRE/ZONING/ENG 01/19/2022 COMPLETED Review Details
11/07/2025 COMMERCIAL REVIEW - FULL REVISION v.1 12/02/2025 REQUIRES RESUBMIT Review Details
12/16/2022 BUILDING DEFERRED SUBMITTAL REVIEW v.1 11/06/2025 REQUIRES RESUBMIT Review Details
12/08/2025 COMMERCIAL REVIEW - FULL REVISION v.2 01/14/2026 APPROVED Review Details

Outstanding Activity Conditions

Permit Number - T21CM09272
Permit Status: Issued
Permit Description: We are filling in the gap in the center between the newly relocated/replace Family Dollar Store whic
Total Outstanding Activity Conditions - 4
Date Name
12/28/2021 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.
12/28/2021 SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED.
12/28/2021 SPECIAL INSPECTION FOR EXPANSION ANCHORS IS REQUIRED.
12/28/2021 SHOP DRAWINGS REQUIRED FOR WOOD I-JOIST

Outstanding Inspections

Permit Status: Issued
Permit Number: T21CM09272
Permite Description: We are filling in the gap in the center between the newly relocated/replace Family Dollar Store whic
Total Outstanding Inspections - 7
Last Inspection Date Description Inspector Results Comments
12/26/2023 COT - LCBU - Preslab N/A Partial Pass
02/19/2026 COT - LCPL - Plumbing Intermediate N/A Re-inspection required 2-19-26: arrived on site at 1234pm. There was nobody inside suite-waited until 1244 and left. Please reschedule.
06/03/2026 COT - LCBU - Building Above Ceiling N/A Not Ready
04/17/2026 COT - LCEL - Electrical Intermediate N/A Partial Pass 4/17/26
Partial pass, missing both exhaust fan wiring, missing circuit B lighting and EM lighting on East wall.
08/12/2026 COT - LCBU - Building Final N/A Not Ready
08/12/2026 COT - HCEL - Electrical Final N/A Re-inspection required Missing panel schedule

8.12.26
1. Missing panel schedule
2. Missing lights in bathroom and mop sink room.
08/12/2026 COT - LCPL - Plumbing Final N/A Re-inspection required 1. Water heater is missing t/p line, connection is behind drywall.
2. Water heater drain needs to be terminated properly, currently there is no drain pipe.
3. Water heater is not working
4. Isolation valve for recirculating pump does not open all the way, it is hitting the pump.
5. Recirculating pump is not wired in.

Completed Inspections

Permit Status: Issued
Permit Number: T21CM09272
Permit Description: We are filling in the gap in the center between the newly relocated/replace Family Dollar Store whic
Total Completed Inspections - 5
Date Description Inspector Results Comments
06/29/2023 BULD - Electrical Clearance Passed 6/29/23: TEP ECO clearance issued.
06/03/2026 COT - LCEL - Electrical Intermediate Passed
08/12/2026 COT - HCME - Mechanical Final Passed
08/12/2026 COT - FCON - Fire - Final Passed
08/12/2026 COT - LCBU - Framing Passed

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD (SSRS).PDF DOCUMENTS VIEW
CONS-100 REVISED FULL CD SET 2(121)) RETAIL TENANT IMPROVEMENTS (PLAN REVIEW COMMENTS) - EL CAMPO CENTER_V2.PDF DOCUMENTS VIEW
APPLICATION 2024 MASS-UPLOAD.PDF DOCUMENTS VIEW
JOB CARD 2024 MASS-UPLOAD.PDF DOCUMENTS VIEW
LETTER TO RUSSLYN WELLS (EXPANSION TENANT SUITE - NEW BLDG C) 2024 MASS-UPLOAD.PDF DOCUMENTS VIEW
PERMIT 2024 MASS-UPLOAD.PDF DOCUMENTS VIEW
PIMA CO ADDRESSING - APPROVAL FOR 121 LETTER 2024 MASS-UPLOAD.PDF DOCUMENTS VIEW
PLAN SET 2024 MASS-UPLOAD.PDF DOCUMENTS VIEW
PSA 2024 MASS-UPLOAD.PDF DOCUMENTS VIEW
STRUCTURAL CALCS 2024 MASS-UPLOAD.PDF DOCUMENTS VIEW
WOODSSTRUCTURAL REVIEW RESPONSE SUITE 121 2024 MASS-UPLOAD.PDF DOCUMENTS VIEW
APPLICATION.PDF DOCUMENTS VIEW
JOB CARD.PDF DOCUMENTS VIEW
LETTER TO RUSSLYN WELLS (EXPANSION TENANT SUITE NEW BLDG C).PDF DOCUMENTS VIEW
PERMIT.PDF DOCUMENTS VIEW
PIMA CO ADDRESSING - APPROVAL FOR #121 LETTER.PDF DOCUMENTS VIEW
PLAN SET.PDF DOCUMENTS VIEW
PSA.PDF DOCUMENTS VIEW
STRUCTURAL CALCS.PDF DOCUMENTS VIEW
WOODSSTRUCTURAL REVIEW RESPONSE SUITE 121.PDF DOCUMENTS VIEW