Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Permit Details

Status:
Issued
Type:
Residential Building - One or Two Family
Apply Date:
11/23/2021
Applicant:
Russ Salmon
Description:
SFR LENNVC354 T20-M0030

Outstanding Activity Conditions

Permit Number - T21CM09119
Permit Status: Issued
Permit Description: SFR LENNVC354 T20-M0030
Total Outstanding Activity Conditions - 2
Date Name
11/23/2021 ROOF TRUSSES MUST BE APPROVED PRIOR TO FRAMING INSPECTION (P2I)
11/23/2021 SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED.

Completed Inspections

Permit Status: Issued
Permit Number: T21CM09119
Permit Description: SFR LENNVC354 T20-M0030
Total Completed Inspections - 23
Date Description Inspector Results Comments
01/13/2022 COT - RSPL - Yard Water Line Passed {Activity date: 01/13/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - AP} ; {Activity date: 01/11/2022; Status: Not ready for Inspection; Inspector: DMUNIZ; Comment: Entered by VVERA1 - Not Ready}
01/13/2022 COT - RSPL - Sewer Passed {Activity date: 01/13/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - AP} ; {Activity date: 01/11/2022; Status: Not ready for Inspection; Inspector: DMUNIZ; Comment: Entered by VVERA1 - Not Ready}
01/13/2022 COT - RSPL - Rough Soil Passed {Activity date: 01/13/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - AP} ; {Activity date: 01/11/2022; Status: Not ready for Inspection; Inspector: DMUNIZ; Comment: Entered by VVERA1 - Not Ready}
02/02/2022 COT - RSEL - Grounding/Bonding Passed {Activity date: 02/02/2022; Status: Approved; Inspector: DMUNIZ; Comment: Entered by NGARCIA3 - Approved}
02/02/2022 COT - RSBU - Preslab Passed {Activity date: 02/02/2022; Status: Approved; Inspector: DMUNIZ; Comment: Entered by NGARCIA3 - Approved}
02/02/2022 COT - RSEL - Electrical Underground Passed {Activity date: 02/02/2022; Status: Approved; Inspector: DMUNIZ; Comment: Entered by NGARCIA3 - Approved}
02/02/2022 COT - RSBU - Excavation/Rebar/Zoning Passed {Activity date: 02/02/2022; Status: Approved; Inspector: DMUNIZ; Comment: Entered by NGARCIA3 - Approved}
03/29/2022 COT - RSBU - Roof Nailing Passed {Activity date: 03/29/2022; Status: Approved; Inspector: DMUNIZ; Comment: Entered by NGARCIA3 - Approved}
03/29/2022 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed {Activity date: 03/29/2022; Status: Approved; Inspector: DMUNIZ; Comment: Entered by NGARCIA3 - Approved}
05/18/2022 PDSD Building Division - TEP PM Clearance Passed {Activity date: 05/18/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - CODE ECO}
05/18/2022 COT - RSEL - Construction Power Passed {Activity date: 05/18/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - AP
TEP ECO}
06/08/2022 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed {Activity date: 06/08/2022; Status: Approved; Inspector: WGALLAGHER; Comment: Entered by VVERA1 - Approved}
06/08/2022 COT - RSPL - Gas Pressure Test Passed {Activity date: 06/08/2022; Status: Approved; Inspector: WGALLAGHER; Comment: Entered by VVERA1 - Approved}
06/09/2022 COT - LCBU - Framing Passed {Activity date: 06/09/2022; Status: Approved; Inspector: DMUNIZ; Comment: Entered by NGARCIA3 - Approved} ; {Activity date: 06/08/2022; Status: Partial Approval; Inspector: WGALLAGHER; Comment: Entered by VVERA1 - Partial approval stair landing missing hangers on joists
}
06/09/2022 RSME - Mechanical Progress Passed {Activity date: 06/09/2022; Status: Approved; Inspector: DMUNIZ; Comment: Entered by NGARCIA3 - Approved} ; {Activity date: 06/08/2022; Status: Partial Approval; Inspector: WGALLAGHER; Comment: Entered by VVERA1 - Partial approval one register box not blocked properly

}
06/10/2022 COT - LCPL - Plumbing Intermediate Passed {Activity date: 06/10/2022; Status: Approved; Inspector: DMUNIZ; Comment: Entered by VVERA1 - Approved} ; {Activity date: 06/09/2022; Status: Correction Required; Inspector: DMUNIZ; Comment: Entered by NGARCIA3 - Corrections required, repair leak under master shower.
} ; {Activity date: 06/08/2022; Status: Partial Approval; Inspector: WGALLAGHER; Comment: Entered by VVERA1 - Partial approval one DWV leak at sanitary T at VTR for upstairs shower, one pex line against gussets above kitchen pony wall, gray water drain above trap at washer not secured, no pressure on solar water heater lines}
06/28/2022 COT - HCBU - Interior Shear Bracing Passed {Activity date: 06/28/2022; Status: Approved; Inspector: DMUNIZ; Comment: Entered by NGARCIA3 - Approved} ; {Activity date: 06/27/2022; Status: Correction Required; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - CO
Do not set screws with a hammer at the shear walls}
08/23/2022 COT - BULD - SWG Clearance Passed {Activity date: 08/23/2022; Status: Approved; Inspector: SCARRAZCO; Comment: Entered by NGARCIA3 - CODE GAS}
08/25/2022 COT - RSEL - Electrical Final Passed {Activity date: 08/25/2022; Status: Approved; Inspector: SCARRAZCO; Comment: Entered by VVERA1 - approved}
08/29/2022 COT - RSME - Mechanical Final Passed {Activity date: 08/29/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP} ; {Activity date: 08/25/2022; Status: Partial Approval; Inspector: SCARRAZCO; Comment: Entered by VVERA1 - partial. Provide proper spacing for condenser unit. Per cut sheet.}
08/29/2022 RSBU - Building Final Passed {Activity date: 08/29/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP} ; {Activity date: 08/25/2022; Status: Partial Approval; Inspector: SCARRAZCO; Comment: Entered by VVERA1 - partial. Missing tempered shower doors. Missing insulation in attic.}
08/29/2022 COT - RSEL - Outdoor Lighting Passed {Activity date: 08/29/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP}
08/29/2022 COT - RSPL - Plumbing Final Passed {Activity date: 08/29/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP} ; {Activity date: 08/25/2022; Status: Partial Approval; Inspector: SCARRAZCO; Comment: Entered by VVERA1 - partial. Paint all pipes that are black} ; {Activity date: 08/23/2022; Status: Partial Approval; Inspector: SCARRAZCO; Comment: Entered by NGARCIA3 - partial. Clearance for southwest gas.}