Permit: T21CM09119
Permit Details
Apply Date:
11/23/2021
Applicant:
Russ Salmon
Description:
SFR LENNVC354 T20-M0030
Outstanding Activity Conditions
Permit Number - T21CM09119
Permit Status: Issued
Permit Description: SFR LENNVC354 T20-M0030
Total Outstanding Activity Conditions - 2
Date | Name |
---|---|
11/23/2021 | ROOF TRUSSES MUST BE APPROVED PRIOR TO FRAMING INSPECTION (P2I) |
11/23/2021 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. |
Completed Inspections
Permit Status: Issued
Permit Number: T21CM09119
Permit Description: SFR LENNVC354 T20-M0030
Total Completed Inspections - 23
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/13/2022 | COT - RSPL - Yard Water Line | Passed | {Activity date: 01/13/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - AP} ; {Activity date: 01/11/2022; Status: Not ready for Inspection; Inspector: DMUNIZ; Comment: Entered by VVERA1 - Not Ready} | |
01/13/2022 | COT - RSPL - Sewer | Passed | {Activity date: 01/13/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - AP} ; {Activity date: 01/11/2022; Status: Not ready for Inspection; Inspector: DMUNIZ; Comment: Entered by VVERA1 - Not Ready} | |
01/13/2022 | COT - RSPL - Rough Soil | Passed | {Activity date: 01/13/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - AP} ; {Activity date: 01/11/2022; Status: Not ready for Inspection; Inspector: DMUNIZ; Comment: Entered by VVERA1 - Not Ready} | |
02/02/2022 | COT - RSEL - Grounding/Bonding | Passed | {Activity date: 02/02/2022; Status: Approved; Inspector: DMUNIZ; Comment: Entered by NGARCIA3 - Approved} | |
02/02/2022 | COT - RSBU - Preslab | Passed | {Activity date: 02/02/2022; Status: Approved; Inspector: DMUNIZ; Comment: Entered by NGARCIA3 - Approved} | |
02/02/2022 | COT - RSEL - Electrical Underground | Passed | {Activity date: 02/02/2022; Status: Approved; Inspector: DMUNIZ; Comment: Entered by NGARCIA3 - Approved} | |
02/02/2022 | COT - RSBU - Excavation/Rebar/Zoning | Passed | {Activity date: 02/02/2022; Status: Approved; Inspector: DMUNIZ; Comment: Entered by NGARCIA3 - Approved} | |
03/29/2022 | COT - RSBU - Roof Nailing | Passed | {Activity date: 03/29/2022; Status: Approved; Inspector: DMUNIZ; Comment: Entered by NGARCIA3 - Approved} | |
03/29/2022 | COT - RSBU - Exterior Clips/Sheathing | Passed | {Activity date: 03/29/2022; Status: Approved; Inspector: DMUNIZ; Comment: Entered by NGARCIA3 - Approved} | |
05/18/2022 | PDSD Building Division - TEP PM Clearance | Passed | {Activity date: 05/18/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - CODE ECO} | |
05/18/2022 | COT - RSEL - Construction Power | Passed | {Activity date: 05/18/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - AP TEP ECO} |
|
06/08/2022 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | {Activity date: 06/08/2022; Status: Approved; Inspector: WGALLAGHER; Comment: Entered by VVERA1 - Approved} | |
06/08/2022 | COT - RSPL - Gas Pressure Test | Passed | {Activity date: 06/08/2022; Status: Approved; Inspector: WGALLAGHER; Comment: Entered by VVERA1 - Approved} | |
06/09/2022 | COT - LCBU - Framing | Passed | {Activity date: 06/09/2022; Status: Approved; Inspector: DMUNIZ; Comment: Entered by NGARCIA3 - Approved} ; {Activity date: 06/08/2022; Status: Partial Approval; Inspector: WGALLAGHER; Comment: Entered by VVERA1 - Partial approval stair landing missing hangers on joists } |
|
06/09/2022 | RSME - Mechanical Progress | Passed | {Activity date: 06/09/2022; Status: Approved; Inspector: DMUNIZ; Comment: Entered by NGARCIA3 - Approved} ; {Activity date: 06/08/2022; Status: Partial Approval; Inspector: WGALLAGHER; Comment: Entered by VVERA1 - Partial approval one register box not blocked properly } |
|
06/10/2022 | COT - LCPL - Plumbing Intermediate | Passed | {Activity date: 06/10/2022; Status: Approved; Inspector: DMUNIZ; Comment: Entered by VVERA1 - Approved} ; {Activity date: 06/09/2022; Status: Correction Required; Inspector: DMUNIZ; Comment: Entered by NGARCIA3 - Corrections required, repair leak under master shower. } ; {Activity date: 06/08/2022; Status: Partial Approval; Inspector: WGALLAGHER; Comment: Entered by VVERA1 - Partial approval one DWV leak at sanitary T at VTR for upstairs shower, one pex line against gussets above kitchen pony wall, gray water drain above trap at washer not secured, no pressure on solar water heater lines} |
|
06/28/2022 | COT - HCBU - Interior Shear Bracing | Passed | {Activity date: 06/28/2022; Status: Approved; Inspector: DMUNIZ; Comment: Entered by NGARCIA3 - Approved} ; {Activity date: 06/27/2022; Status: Correction Required; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - CO Do not set screws with a hammer at the shear walls} |
|
08/23/2022 | COT - BULD - SWG Clearance | Passed | {Activity date: 08/23/2022; Status: Approved; Inspector: SCARRAZCO; Comment: Entered by NGARCIA3 - CODE GAS} | |
08/25/2022 | COT - RSEL - Electrical Final | Passed | {Activity date: 08/25/2022; Status: Approved; Inspector: SCARRAZCO; Comment: Entered by VVERA1 - approved} | |
08/29/2022 | COT - RSME - Mechanical Final | Passed | {Activity date: 08/29/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP} ; {Activity date: 08/25/2022; Status: Partial Approval; Inspector: SCARRAZCO; Comment: Entered by VVERA1 - partial. Provide proper spacing for condenser unit. Per cut sheet.} | |
08/29/2022 | RSBU - Building Final | Passed | {Activity date: 08/29/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP} ; {Activity date: 08/25/2022; Status: Partial Approval; Inspector: SCARRAZCO; Comment: Entered by VVERA1 - partial. Missing tempered shower doors. Missing insulation in attic.} | |
08/29/2022 | COT - RSEL - Outdoor Lighting | Passed | {Activity date: 08/29/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP} | |
08/29/2022 | COT - RSPL - Plumbing Final | Passed | {Activity date: 08/29/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP} ; {Activity date: 08/25/2022; Status: Partial Approval; Inspector: SCARRAZCO; Comment: Entered by VVERA1 - partial. Paint all pipes that are black} ; {Activity date: 08/23/2022; Status: Partial Approval; Inspector: SCARRAZCO; Comment: Entered by NGARCIA3 - partial. Clearance for southwest gas.} |