Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
Commercial Building
Address:
1 S CHURCH AV
Apply Date:
11/16/2021
Applicant:
Description:
Exterior façade improvements at the west building entry, new restaurant patio awnings and restaurant

Permit Reviews

Permit Number - T21CM08943
Permit Status: Expired
Permit Description: Exterior façade improvements at the west building entry, new restaurant patio awnings and restaurant
Start Date Submittal Complete Date Status  
01/07/2022 RESUBMITTAL 01/25/2022 COMPLETED Review Details
12/10/2021 COMMERCIAL - BLDG/FIRE/ZONING/ENG 01/05/2022 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T21CM08943
Permit Status: Expired
Permit Description: Exterior façade improvements at the west building entry, new restaurant patio awnings and restaurant
Total Outstanding Activity Conditions - 3
Date Name
01/20/2022 SPECIAL INSPECTION FOR BOLTS INSTALLED IN CONCRETE IS REQUIRED.
01/20/2022 SPECIAL INSPECTION FOR HIGH STRENGTH BOLTING IS REQUIRED.
01/20/2022 SPECIAL INSPECTION FOR FIELD WELDING IS REQUIRED.

Outstanding Inspections

Permit Status: Expired
Permit Number: T21CM08943
Permite Description: Exterior façade improvements at the west building entry, new restaurant patio awnings and restaurant
Total Outstanding Inspections - 11
Last Inspection Date Description Inspector Results Comments
11/04/2022 COT - LCEL - Electrical Progress N/A Canceled Inspection Canceled
11/04/2022 COT - LCEL - Electrical Intermediate N/A Canceled Inspection Canceled
11/04/2022 COT - LCBU - Framing N/A Canceled Inspection Canceled
11/04/2022 COT - LCEL - Outdoor Lighting N/A Canceled Inspection Canceled
11/04/2022 COT - LCEL - Electrical Final N/A Canceled Inspection Canceled
11/04/2022 COT - LCBU - Exterior Clips/Sheathing N/A Canceled Inspection Canceled
11/04/2022 COT - LCBU - Sustainability N/A Canceled Inspection Canceled
11/04/2022 COT - FCON - Fire - Final N/A Canceled Inspection Canceled
11/04/2022 COT - LCEL - Electrical Above Ceiling N/A Canceled Inspection Canceled
11/04/2022 COT - LCEL - Service Upgrade N/A Canceled Inspection Canceled
11/04/2022 COT - LCBU - Building Progress N/A Canceled Inspection Canceled

Completed Inspections

Permit Status: Expired
Permit Number: T21CM08943
Permit Description: Exterior façade improvements at the west building entry, new restaurant patio awnings and restaurant
Total Completed Inspections - 1
Date Description Inspector Results Comments
06/06/2023 COT - LCBU - Building Final Passed All inspections have been cleared at this time

Documents

File Name Document Type  
APPLICATION 2024 MASS-UPLOAD.PDF DOCUMENTS VIEW
CHECKLIST 2024 MASS-UPLOAD.PDF DOCUMENTS VIEW
JOB CARD 2024 MASS-UPLOAD.PDF DOCUMENTS VIEW
PERMIT 2024 MASS-UPLOAD.PDF DOCUMENTS VIEW
PLAN SET 2024 MASS-UPLOAD.PDF DOCUMENTS VIEW
PROJECT MANUAL 2024 MASS-UPLOAD.PDF DOCUMENTS VIEW
STRUCTURAL CALCULATIONS 2024 MASS-UPLOAD.PDF DOCUMENTS VIEW
PLAN SET.PDF DOCUMENTS VIEW
PERMIT.PDF DOCUMENTS VIEW
JOB CARD.PDF DOCUMENTS VIEW
CHECKLIST.PDF DOCUMENTS VIEW
APPLICATION.PDF DOCUMENTS VIEW
STRUCTURAL CALCULATIONS.PDF DOCUMENTS VIEW
PROJECT MANUAL.PDF DOCUMENTS VIEW