Permit: T21CM08844
Permit Details
Status:
Issued
Type:
Residential Building - One or Two Family
Address:
912 W NEARMONT DR
Address NEW:
912 W NEARMONT DR
Apply Date:
11/12/2021
Applicant:
CAELIN NORGORD
Description:
SFR with Sleeping Quarters
Outstanding Activity Conditions
Permit Number - T21CM08844
Permit Status: Issued
Permit Description: SFR with Sleeping Quarters
Total Outstanding Activity Conditions - 2
| Date | Name |
|---|---|
| 02/16/2022 | This building permit approval is without public sewer connection review or approval. It is strictly the responsibility of the owner and/or person doing the work to ensure that the appropriate review and approval to connect is obtained from Regional Wastewater Reclamation Department (RWRD) wastewater provider or Pima County DEQ approval of/and alternative disposal system. It is required that owner and/or person doing the work solicit all requisite approvals from the wastewater provider prior to obtaining this building construction permit. RWRD connection information is available at www.pima.gov/wwm/developer.htm |
| 02/16/2022 | PIMA COUNTY WASTEWATER SIGN OFF REQUIRED PRIOR TO ISSUANCE OF FINAL STATUS. |
Outstanding Inspections
Permit Status: Issued
Permit Number: T21CM08844
Permite Description: SFR with Sleeping Quarters
Total Outstanding Inspections - 7
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/26/2022 | COT - RSBU - Firewall/Fire Barrier/Firestop | N/A | Not Ready | |
| 10/26/2022 | COT - RSPL - Yard Water Line | N/A | Not Ready | |
| 10/27/2022 | COT - RSEL - Outdoor Lighting | N/A | Not Ready | |
| 10/26/2022 | COT - RSPL - Sewer | N/A | Not Ready | |
| 10/26/2022 | COT - RSPL - Gas Pressure Test | N/A | Not Ready | |
| 10/26/2022 | COT - RSBU - Masonry Pregrout | N/A | Not Ready | |
| 10/27/2022 | COT - RSPL - Plumbing Final | N/A | Not Ready |
Completed Inspections
Permit Status: Issued
Permit Number: T21CM08844
Permit Description: SFR with Sleeping Quarters
Total Completed Inspections - 16
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/22/2022 | COT - RSEL - Grounding/Bonding | Passed | {Activity date: 02/22/2022; Status: Approved; Inspector: JBURGE; Comment: Entered by VVERA1 - Approved. Rebar ufer.} | |
| 02/22/2022 | COT - RSBU - Excavation/Rebar/Zoning | Passed | {Activity date: 02/22/2022; Status: Approved; Inspector: JBURGE; Comment: Entered by VVERA1 - Approved. Ok to place concrete in progress areas} | |
| 03/17/2022 | COT - RSPL - Rough Soil | Passed | {Activity date: 03/17/2022; Status: Approved; Inspector: DQUINN; Comment: Entered by NGARCIA3 - Ap ABS for 2 new interior and 2 exterior baths ok to backfill.} |
|
| 03/21/2022 | COT - RSBU - Preslab | Passed | {Activity date: 03/21/2022; Status: Approved; Inspector: JBURGE; Comment: Entered by NGARCIA3 - Approved. Ok to place concrete. Ensure slab is properly termite treated.} | |
| 04/29/2022 | PDSD Building Division - TEP PM Clearance | Passed | {Activity date: 04/29/2022; Status: Approved; Inspector: DQUINN; Comment: Entered by VVERA1 - CODE INCR} | |
| 04/29/2022 | COT - RSEL - Construction Power | Passed | {Activity date: 04/29/2022; Status: Approved; Inspector: DQUINN; Comment: Entered by VVERA1 - Ap Clear incr} |
|
| 06/10/2022 | COT - RSBU - Roof Nailing | Passed | {Activity date: 06/10/2022; Status: Approved; Inspector: JBURGE; Comment: Entered by NGARCIA3 - . Approved. Ok to dry in roof system.} ; {Activity date: 06/10/2022; Status: Approved; Inspector: JBURGE; Comment: Entered by VVERA1 - Approved. Ok to dry in roof system.} ; {Activity date: 04/05/2022; Status: Not ready for Inspection; Inspector: JBURGE; Comment: Entered by NGARCIA3 - Not ready. Called in for 01020 inspection. } |
|
| 06/10/2022 | COT - LCBU - Framing | Passed | {Activity date: 06/10/2022; Status: Approved; Inspector: JBURGE; Comment: Entered by NGARCIA3 - Approved} ; {Activity date: 06/10/2022; Status: Approved; Inspector: JBURGE; Comment: Entered by VVERA1 - Approved} | |
| 06/10/2022 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | {Activity date: 06/10/2022; Status: Approved; Inspector: JBURGE; Comment: Entered by NGARCIA3 - Approved} ; {Activity date: 06/10/2022; Status: Approved; Inspector: JBURGE; Comment: Entered by VVERA1 - Approved} | |
| 07/07/2022 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | {Activity date: 07/07/2022; Status: Approved; Inspector: JBURGE; Comment: Entered by NGARCIA3 - Approved. Ok to insulate and cover walls} | |
| 07/07/2022 | COT - LCPL - Plumbing Intermediate | Passed | {Activity date: 07/07/2022; Status: Approved; Inspector: JBURGE; Comment: Entered by NGARCIA3 - Approved} | |
| 07/07/2022 | RSME - Mechanical Progress | Passed | {Activity date: 07/07/2022; Status: Approved; Inspector: JBURGE; Comment: Entered by NGARCIA3 - Approved} | |
| 12/29/2022 | COT - RSEL - Electrical Final | Passed | ||
| 12/29/2022 | COT - RSME - Mechanical Final | Passed | ||
| 12/29/2022 | RSBU - Building Final | Passed | ||
| 12/29/2022 | COT - RSPL - Plumbing Final | Passed |