Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T21CM08267
Permit Details
Apply Date:
10/20/2021
Applicant:
KB HOME OF TUCSON *APA*
Description:
SFR KBHO1842A19 T19-M0157
Contractors:
- KB HOME OF TUCSON *APA*
Outstanding Activity Conditions
Permit Number - T21CM08267
Permit Status: Final
Permit Description: SFR KBHO1842A19 T19-M0157
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
10/20/2021 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T21CM08267
Permit Description: SFR KBHO1842A19 T19-M0157
Total Completed Inspections - 23
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/28/2021 | PLUMBING - FINAL | CVASQUE2 | Approved | NO FINAL TILL THE PUBLIC SEWER G-2020-078 IS ACCEPTED AND RELEASED BY PCRWRD |
11/05/2021 | PLUMBING - YARD WTR LINE/TEST | RCHANDLER | Approved | PA. Test is less than 50#. Bury at own risk. |
11/05/2021 | PLUMBING - ROUGH, SOIL | RCHANDLER | Approved | -AP |
11/05/2021 | PLUMBING - SEWER HCS CONNECT | RCHANDLER | Approved | -AP |
11/15/2021 | BUILDING PRE-SLAB | WGALLAGHER | Approved | |
11/15/2021 | EXCAVATION/LAYOUT REBAR & ZON | WGALLAGHER | Approved | |
11/26/2021 | EXT METAL CLIPS/EXT SHEATHING | TLUNDBERG | Approved | AP |
12/03/2021 | ROOF NAILING | WGALLAGHER | Approved | Approved |
02/15/2022 | FRAMING | WGALLAGHER | Approved | Approved |
02/15/2022 | RESIDENTIAL INTERMEDIATE | WGALLAGHER | Approved | Approved |
02/15/2022 | PLUMBING - INTERMEDIATE | WGALLAGHER | Approved | Approved |
02/16/2022 | TEP CLEARANCE - PM | TLUNDBERG | Approved | CODE ECO |
02/16/2022 | MECHANICAL - INTERMEDIATE | TLUNDBERG | Approved | AP |
02/16/2022 | ELECTRIC - CONSTRUCTION POWER | TLUNDBERG | Approved | AP TEP ECO |
03/02/2022 | SHEET ROCK NAILING | TLUNDBERG | Approved | AP |
05/26/2022 | GAS CLEARANCE | ESTEVENS | Approved | CODE |
05/27/2022 | MECHANICAL - FINAL | WGALLAGHER | Approved | |
05/27/2022 | PLUMBING - GAS PRESSURE TEST | WGALLAGHER | Approved | |
05/27/2022 | OUTDOOR LIGHTING FINAL | WGALLAGHER | Approved | |
05/27/2022 | ELECTRIC - FINAL | WGALLAGHER | Approved | |
05/27/2022 | ELECTRIC - UNDERGROUND | WGALLAGHER | Approved | |
05/27/2022 | ELECTRIC - UFER | WGALLAGHER | Approved | |
05/27/2022 | BUILDING - FINAL | WGALLAGHER | Approved |