Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T21CM08114
Permit Details
Apply Date:
10/13/2021
Applicant:
Andrea Flood
Description:
SFR F40G19 T19-M0038
Conditions
Permit Number - T21CM08114
Permit Status: Complete
Permit Description: SFR F40G19 T19-M0038
Date | Description | Comments |
---|---|---|
10/13/2021 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. | |
10/13/2021 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. | |
10/13/2021 | SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED. |
Completed Inspections
Permit Status: Complete
Permit Number: T21CM08114
Permit Description: SFR F40G19 T19-M0038
Total Completed Inspections - 18
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/24/2021 | COT - RSPL - Yard Water Line | Passed | {Activity date: 11/24/2021; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by RSALDAT1 - AP} | |
11/24/2021 | COT - RSPL - Sewer | Passed | {Activity date: 11/24/2021; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by RSALDAT1 - AP} | |
11/24/2021 | COT - RSPL - Rough Soil | Passed | {Activity date: 11/24/2021; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by RSALDAT1 - AP} | |
12/03/2021 | COT - RSEL - Grounding/Bonding | Passed | {Activity date: 12/03/2021; Status: Approved; Inspector: WGALLAGHER; Comment: Entered by NGARCIA3 - Approved} | |
12/03/2021 | COT - RSBU - Preslab | Passed | {Activity date: 12/03/2021; Status: Approved; Inspector: WGALLAGHER; Comment: Entered by NGARCIA3 - Approved} | |
12/03/2021 | COT - RSEL - Electrical Underground | Passed | {Activity date: 12/03/2021; Status: Approved; Inspector: WGALLAGHER; Comment: Entered by NGARCIA3 - Approved} | |
12/03/2021 | COT - RSBU - Excavation/Rebar/Zoning | Passed | {Activity date: 12/03/2021; Status: Approved; Inspector: WGALLAGHER; Comment: Entered by NGARCIA3 - Approved} | |
01/13/2022 | COT - RSBU - Roof Nailing | Passed | {Activity date: 01/13/2022; Status: Approved; Inspector: WGALLAGHER; Comment: Entered by VVERA1 - Approved} | |
04/01/2022 | PDSD Building Division - TEP PM Clearance | Passed | {Activity date: 04/01/2022; Status: Approved; Inspector: WGALLAGHER; Comment: Entered by VVERA1 - CODE ECO} | |
04/01/2022 | COT - RSEL - Construction Power | Passed | {Activity date: 04/01/2022; Status: Approved; Inspector: WGALLAGHER; Comment: Entered by VVERA1 - Approved ok for clearance ECO } |
|
07/14/2022 | COT - RSBU - Exterior Clips/Sheathing | Passed | {Activity date: 07/14/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP} ; {Activity date: 01/13/2022; Status: Partial Approval; Inspector: WGALLAGHER; Comment: Entered by VVERA1 - Partial approval Interior walls are not tagged to trust blocking properly several locations in a improper blocking above headers several locations need fire stop at front entry at top plate level} | |
07/27/2022 | COT - LCPL - Plumbing Intermediate | Passed | {Activity date: 07/27/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - AP} | |
07/27/2022 | RSEL - Electrical Progress | Passed | {Activity date: 07/27/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - AP} | |
07/27/2022 | RSME - Mechanical Progress | Passed | {Activity date: 07/27/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - AP} | |
07/27/2022 | COT - RSPL - Gas Pressure Test | Passed | {Activity date: 07/27/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - AP} | |
07/29/2022 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | {Activity date: 07/29/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP} ; {Activity date: 07/27/2022; Status: Denied; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - DE 1. Repair abandoned hole in roof 2. Shim the trusses at the mid-bearing point 3. Move hall SD 3 feet from register} |
|
07/29/2022 | COT - LCBU - Framing | Passed | {Activity date: 07/29/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP} ; {Activity date: 07/27/2022; Status: Denied; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - DE} | |
08/08/2022 | COT - HCBU - Interior Shear Bracing | Passed | {Activity date: 08/08/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - AP} |