Start Date | Submittal | Complete Date | Status |
---|---|---|---|
10/12/2021 | RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO | 11/04/2021 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T21CM08094
Permit Status: Complete
Permit Description: DUPLEX DPLAN2114 T21-M0004
Total Outstanding Activity Conditions - 2
Date | Name |
---|---|
10/12/2021 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
10/12/2021 | ROOF TRUSSES MUST BE APPROVED PRIOR TO FRAMING INSPECTION (P2I) |
Outstanding Inspections
Permit Status: Complete
Permit Number: T21CM08094
Permite Description: DUPLEX DPLAN2114 T21-M0004
Total Outstanding Inspections - 2
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/30/2023 | COT - RSEL - Electrical Final | N/A | Re-inspection required | |
10/26/2022 | COT - RSPL - Sewer | N/A | Not Ready |
Completed Inspections
Permit Status: Complete
Permit Number: T21CM08094
Permit Description: DUPLEX DPLAN2114 T21-M0004
Total Completed Inspections - 23
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/19/2021 | COT - RSEL - Grounding/Bonding | Passed | {Activity date: 11/19/2021; Status: Approved; Inspector: DMUNIZ; Comment: Entered by VVERA1 - Approved} | |
11/19/2021 | COT - RSBU - Preslab | Passed | {Activity date: 11/19/2021; Status: Approved; Inspector: DMUNIZ; Comment: Entered by VVERA1 - Approved} | |
11/19/2021 | COT - RSBU - Excavation/Rebar/Zoning | Passed | {Activity date: 11/19/2021; Status: Approved; Inspector: DMUNIZ; Comment: Entered by VVERA1 - Approved} | |
04/20/2022 | COT - RSEL - Construction Power | Passed | {Activity date: 04/20/2022; Status: Approved; Inspector: WGALLAGHER; Comment: Entered by VVERA1 - Approved ok for clearance ECO } |
|
04/20/2022 | BULD - Electrical Clearance | Passed | {Activity date: 04/20/2022; Status: Approved; Inspector: WGALLAGHER; Comment: Entered by VVERA1 - CODE ECO} | |
04/27/2022 | COT - RSBU - Roof Nailing | Passed | {Activity date: 04/27/2022; Status: Approved; Inspector: DMUNIZ; Comment: Entered by VVERA1 - Approved} ; {Activity date: 04/25/2022; Status: Not ready for Inspection; Inspector: DMUNIZ; Comment: Entered by NGARCIA3 - Not Ready} | |
04/27/2022 | COT - RSBU - Exterior Clips/Sheathing | Passed | {Activity date: 04/27/2022; Status: Approved; Inspector: DMUNIZ; Comment: Entered by VVERA1 - Approved} ; {Activity date: 04/25/2022; Status: Not ready for Inspection; Inspector: DMUNIZ; Comment: Entered by NGARCIA3 - Not Ready} | |
05/04/2022 | COT - RSPL - Yard Water Line | Passed | {Activity date: 05/04/2022; Status: Approved; Inspector: DMUNIZ; Comment: Entered by VVERA1 - Approved} | |
05/04/2022 | COT - RSPL - Rough Soil | Passed | {Activity date: 05/04/2022; Status: Approved; Inspector: DMUNIZ; Comment: Entered by VVERA1 - Approved} ; {Activity date: 11/15/2021; Status: Partial Approval; Inspector: DMUNIZ; Comment: Entered by RSALDAT1 - Partial, Plumbing under slab for both units ok to backfill.} | |
05/04/2022 | RSME - Mechanical Progress | Passed | {Activity date: 05/04/2022; Status: Approved; Inspector: DMUNIZ; Comment: Entered by VVERA1 - Approved} ; {Activity date: 04/20/2022; Status: Partial Approval; Inspector: WGALLAGHER; Comment: Entered by VVERA1 - Partial approval require fresh air intake } |
|
05/10/2022 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | {Activity date: 05/10/2022; Status: Approved; Inspector: DMUNIZ; Comment: Entered by NGARCIA3 - Approved} ; {Activity date: 05/09/2022; Status: Cancelled; Inspector: IVR USER; Comment: Entered by IVR USER - IVRS - RI canceled} ; {Activity date: 05/04/2022; Status: Correction Required; Inspector: DMUNIZ; Comment: Entered by VVERA1 - corrections required, repair all damaged circuit.} ; {Activity date: 04/20/2022; Status: Partial Approval; Inspector: WGALLAGHER; Comment: Entered by VVERA1 - Partial approval sub panels must have split neutral/ground buss one side isn’t split.} | |
05/10/2022 | COT - LCBU - Framing | Passed | {Activity date: 05/10/2022; Status: Approved; Inspector: DMUNIZ; Comment: Entered by NGARCIA3 - Approved} ; {Activity date: 05/09/2022; Status: Cancelled; Inspector: IVR USER; Comment: Entered by IVR USER - IVRS - RI canceled} ; {Activity date: 05/04/2022; Status: Correction Required; Inspector: DMUNIZ; Comment: Entered by VVERA1 - corrections required, provide nail protection where needed and seal all top plate penetrations.} ; {Activity date: 04/27/2022; Status: Not ready for Inspection; Inspector: DMUNIZ; Comment: Entered by VVERA1 - not ready } ; {Activity date: 04/25/2022; Status: Not ready for Inspection; Inspector: DMUNIZ; Comment: Entered by NGARCIA3 - Not Ready} |
|
05/10/2022 | COT - RSBU - Firewall/Fire Barrier/Firestop | Passed | {Activity date: 05/10/2022; Status: Approved; Inspector: DMUNIZ; Comment: Entered by NGARCIA3 - Approved} ; {Activity date: 05/09/2022; Status: Cancelled; Inspector: IVR USER; Comment: Entered by IVR USER - IVRS - RI canceled} ; {Activity date: 05/04/2022; Status: Correction Required; Inspector: DMUNIZ; Comment: Entered by VVERA1 - corrections required, Provide a chase conduit for feeder penetrating fire wall.} ; {Activity date: 04/27/2022; Status: Not ready for Inspection; Inspector: DMUNIZ; Comment: Entered by VVERA1 - not ready } ; {Activity date: 04/25/2022; Status: Not ready for Inspection; Inspector: DMUNIZ; Comment: Entered by NGARCIA3 - Not Ready} |
|
05/10/2022 | COT - LCPL - Plumbing Intermediate | Passed | {Activity date: 05/10/2022; Status: Approved; Inspector: DMUNIZ; Comment: Entered by NGARCIA3 - Approved} ; {Activity date: 05/09/2022; Status: Cancelled; Inspector: IVR USER; Comment: Entered by IVR USER - IVRS - RI canceled} ; {Activity date: 05/04/2022; Status: Correction Required; Inspector: DMUNIZ; Comment: Entered by VVERA1 - corrections required, provide DWV test and fire rating on washer box. Install fire putty pads on laundry outlet locations in fire wall.} ; {Activity date: 04/20/2022; Status: Partial Approval; Inspector: WGALLAGHER; Comment: Entered by VVERA1 - Partial approval no s trap allowed on washer drain, require blocking for gas drop and should be 3/4 inch, no DWV TEST, no shower pan or tubs under test,} | |
05/10/2022 | COT - RSPL - Gas Pressure Test | Passed | {Activity date: 05/10/2022; Status: Approved; Inspector: DMUNIZ; Comment: Entered by NGARCIA3 - Approved} ; {Activity date: 05/09/2022; Status: Cancelled; Inspector: IVR USER; Comment: Entered by IVR USER - IVRS - RI canceled} ; {Activity date: 05/04/2022; Status: Not ready for Inspection; Inspector: DMUNIZ; Comment: Entered by VVERA1 - Not Ready} ; {Activity date: 04/20/2022; Status: Not ready for Inspection; Inspector: WGALLAGHER; Comment: Entered by VVERA1 - Not ready see 3035 } |
|
08/09/2022 | PDSD Building Division - TEP PM Clearance | Passed | {Activity date: 08/09/2022; Status: Approved; Inspector: WGALLAGHER; Comment: Entered by RSALDAT1 - CODE ECO/ UNITS 1 & 2.} | |
05/31/2023 | COT - RSEL - Electrical Final | Passed | ||
05/31/2023 | COT - RSPL - Sewer | Passed | ||
05/31/2023 | COT - RSPL - Plumbing Final | Passed | ||
05/31/2023 | RSBU - Building Final | Passed | ||
05/31/2023 | COT - RSEL - Outdoor Lighting | Passed | ||
05/31/2023 | COT - RSEL - Electrical Underground | Passed | ||
05/31/2023 | COT - RSME - Mechanical Final | Passed |