Permit Details

Status:
Complete
Type:
Commercial Building
Apply Date:
09/24/2021
Applicant:
Description:
New Community Building, covered patios, detached ramada, site lighting & pickle ball court

Permit Reviews

Permit Number - T21CM07679
Permit Status: Complete
Permit Description: New Community Building, covered patios, detached ramada, site lighting & pickle ball court
Start Date Submittal Complete Date Status  
09/24/2021 COMMERCIAL - NEW 12/14/2021 COMPLETED Review Details
09/29/2022 RESUBMITTAL 10/13/2022 COMPLETED Review Details
10/15/2022 RESUBMITTAL 10/15/2022 ACTIVE Review Details
11/20/2023 BUILDING DEFERRED SUBMITTAL REVIEW v.1 11/21/2023 APPROVED Review Details
08/23/2023 BUILDING DEFERRED SUBMITTAL REVIEW v.1 08/28/2023 APPROVED Review Details
11/01/2023 BUILDING DEFERRED SUBMITTAL REVIEW v.1 11/02/2023 APPROVED Review Details
12/14/2022 COMMERCIAL REVIEW - FULL v.1 01/12/2023 APPROVED Review Details
10/28/2022 COMMERCIAL REVIEW - FULL v.1 11/01/2022 REQUIRES RESUBMIT Review Details
11/15/2022 COMMERCIAL REVIEW - FULL v.2 12/14/2022 REQUIRES RESUBMIT Review Details

Conditions

Permit Number - T21CM07679
Permit Status: Complete
Permit Description: New Community Building, covered patios, detached ramada, site lighting & pickle ball court
Date Description Comments
11/15/2022 AIR BALANCING/COMMISSIONING REPORT IS REQUIRED.
10/04/2021 ROOF TRUSSES MUST BE APPROVED PRIOR TO FRAMING INSPECTION (P2I)
10/04/2021 SPECIAL INSPECTION FOR CONCRETE IS REQUIRED..
10/04/2021 SPECIAL INSPECTION FOR REINFORCING STEEL AND/OR PRE-STRESSING TENDONS IS REQUIRED.
10/04/2021 SPECIAL INSPECTION FOR STRUCTURAL WELDING IS REQUIRED.
10/04/2021 SPECIAL INSPECTION FOR HIGH STRENGTH BOLTING IS REQUIRED.
10/04/2021 SPECIAL INSPECTION FOR STRUCTURAL MASONRY IS REQUIRED.
10/04/2021 SPECIAL INSPECTION FOR SITE PREPARATION IS REQUIRED.
10/04/2021 SPECIAL INSPECTION FOR FIELD WELDING IS REQUIRED.
10/04/2021 SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED.
10/11/2022 SPECIAL INSPECTION REQUIRED FOR OUTDOOR LIGHTING
01/12/2023 Contractor with active Arizona Contractor's License for specified scope of work required prior to issuance of permit.
11/15/2022 WATER STERILIZATION REPORT IS REQUIRED.

Outstanding Inspections

Permit Status: Complete
Permit Number: T21CM07679
Permite Description: New Community Building, covered patios, detached ramada, site lighting & pickle ball court
Total Outstanding Inspections - 5
Last Inspection Date Description Inspector Results Comments
08/14/2023 COT - LCEL - Electrical Final N/A Re-inspection required 8/14/23: city approved plans are required on site. No record of any framing or grout inspections. Blank cover missing in electric panel. Secure NMC cable to wall at water heater. All exterior electric outlets are required to be WR. Both ADA sinks exceed 34", men's toilet exceeds 18" off wall, wrap plumbing under sinks, incorrect restroom signage, toilet flush valve not on the open side in men's restroom, grab bars missing in shower, seat missing in shower, coat hooks exceed max 48" off floor.Support NMC cable in court yard off concrete
08/14/2023 COT - HCBU - Building Final N/A Re-inspection required 8/14/23: city approved plans are required on site. No record of any framing or grout inspections. Blank cover missing in electric panel. Secure NMC cable to wall at water heater. All exterior electric outlets are required to be WR. Both ADA sinks exceed 34", men's toilet exceeds 18" off wall, wrap plumbing under sinks, incorrect restroom signage, toilet flush valve not on the open side in men's restroom, grab bars missing in shower, seat missing in shower, coat hooks exceed max 48" off floor.Support NMC cable in court yard off concrete
08/14/2023 COT - HCEL - Electrical Final N/A Re-inspection required 8/14/23: city approved plans are required on site. No record of any framing or grout inspections. Blank cover missing in electric panel. Secure NMC cable to wall at water heater. All exterior electric outlets are required to be WR. Both ADA sinks exceed 34", men's toilet exceeds 18" off wall, wrap plumbing under sinks, incorrect restroom signage, toilet flush valve not on the open side in men's restroom, grab bars missing in shower, seat missing in shower, coat hooks exceed max 48" off floor.Support NMC cable in court yard off concrete
08/14/2023 COT - HCME - Mechanical Final N/A Re-inspection required 8/14/23: city approved plans are required on site. No record of any framing or grout inspections. Blank cover missing in electric panel. Secure NMC cable to wall at water heater. All exterior electric outlets are required to be WR. Both ADA sinks exceed 34", men's toilet exceeds 18" off wall, wrap plumbing under sinks, incorrect restroom signage, toilet flush valve not on the open side in men's restroom, grab bars missing in shower, seat missing in shower, coat hooks exceed max 48" off floor.Support NMC cable in court yard off concrete
08/14/2023 COT - HCPL - Plumbing Final N/A Re-inspection required 8/14/23: city approved plans are required on site. No record of any framing or grout inspections. Blank cover missing in electric panel. Secure NMC cable to wall at water heater. All exterior electric outlets are required to be WR. Both ADA sinks exceed 34", men's toilet exceeds 18" off wall, wrap plumbing under sinks, incorrect restroom signage, toilet flush valve not on the open side in men's restroom, grab bars missing in shower, seat missing in shower, coat hooks exceed max 48" off floor.Support NMC cable in court yard off concrete

Completed Inspections

Permit Status: Complete
Permit Number: T21CM07679
Permit Description: New Community Building, covered patios, detached ramada, site lighting & pickle ball court
Total Completed Inspections - 26
Date Description Inspector Results Comments
03/01/2023 COT - HCPL - Sewer Passed
03/27/2023 COT - LCEL - Electrical Underground Passed
03/27/2023 COT - LCEL - Grounding/Bonding Passed
03/29/2023 COT - HCPL - Rough Soil Passed
03/29/2023 COT - HCPL - Yard Water Line Passed
03/29/2023 COT - LCPL - Plumbing Progress Passed
04/05/2023 COT - LCBU - Excavation/Rebar/Zoning Passed
04/05/2023 COT - LCBU - Preslab Passed
04/13/2023 COT - HCEL - Electrical Underground Passed
04/13/2023 COT - HCEL - Grounding/Bonding Passed
06/05/2023 COT - LCEL - Electrical Above Ceiling Passed
06/05/2023 COT - LCEL - Electrical Intermediate Passed
06/05/2023 COT - HCPL - Plumbing Intermediate Passed
06/05/2023 COT - HCME - Mechanical Intermediate Passed
06/05/2023 BULD - Electrical Clearance Passed
08/14/2023 COT - LCEL - Electrical Progress Passed
08/14/2023 COT - LCEL - Outdoor Lighting Passed
08/14/2023 COT - FCON - Alarm - Final Passed no alarms
08/14/2023 COT - FCON - Fire - Final Passed
09/14/2023 COT - FCON - Sprinkler - Final Passed there are no sprinklers in this area.
09/05/2023 ENGR Engineering Final Passed
09/05/2023 COT - LCEL - Electrical Final Passed 8/14/23: city approved plans are required on site. No record of any framing or grout inspections. Blank cover missing in electric panel. Secure NMC cable to wall at water heater. All exterior electric outlets are required to be WR. Both ADA sinks exceed 34", men's toilet exceeds 18" off wall, wrap plumbing under sinks, incorrect restroom signage, toilet flush valve not on the open side in men's restroom, grab bars missing in shower, seat missing in shower, coat hooks exceed max 48" off floor.Support NMC cable in court yard off concrete

9/5/23: all corrections made
09/05/2023 COT - HCBU - Building Final Passed 8/14/23: city approved plans are required on site. No record of any framing or grout inspections. Blank cover missing in electric panel. Secure NMC cable to wall at water heater. All exterior electric outlets are required to be WR. Both ADA sinks exceed 34", men's toilet exceeds 18" off wall, wrap plumbing under sinks, incorrect restroom signage, toilet flush valve not on the open side in men's restroom, grab bars missing in shower, seat missing in shower, coat hooks exceed max 48" off floor.Support NMC cable in court yard off concrete

9/5/23: all corrections made
09/05/2023 COT - HCEL - Electrical Final Passed 8/14/23: city approved plans are required on site. No record of any framing or grout inspections. Blank cover missing in electric panel. Secure NMC cable to wall at water heater. All exterior electric outlets are required to be WR. Both ADA sinks exceed 34", men's toilet exceeds 18" off wall, wrap plumbing under sinks, incorrect restroom signage, toilet flush valve not on the open side in men's restroom, grab bars missing in shower, seat missing in shower, coat hooks exceed max 48" off floor.Support NMC cable in court yard off concrete

9/5/23: all corrections made
09/05/2023 COT - HCME - Mechanical Final Passed 8/14/23: city approved plans are required on site. No record of any framing or grout inspections. Blank cover missing in electric panel. Secure NMC cable to wall at water heater. All exterior electric outlets are required to be WR. Both ADA sinks exceed 34", men's toilet exceeds 18" off wall, wrap plumbing under sinks, incorrect restroom signage, toilet flush valve not on the open side in men's restroom, grab bars missing in shower, seat missing in shower, coat hooks exceed max 48" off floor.Support NMC cable in court yard off concrete

9/5/23: all corrections made
09/05/2023 COT - HCPL - Plumbing Final Passed 8/14/23: city approved plans are required on site. No record of any framing or grout inspections. Blank cover missing in electric panel. Secure NMC cable to wall at water heater. All exterior electric outlets are required to be WR. Both ADA sinks exceed 34", men's toilet exceeds 18" off wall, wrap plumbing under sinks, incorrect restroom signage, toilet flush valve not on the open side in men's restroom, grab bars missing in shower, seat missing in shower, coat hooks exceed max 48" off floor.Support NMC cable in court yard off concrete

9/5/23: all corrections made

Documents

File Name Document Type  
COFO_FINALCOFO_COMMERCIAL.PDF DOCUMENTS VIEW
06100-04 ROOF TRUSSES - REVIEWED 042023_V1.PDF DOCUMENTS VIEW
2023 CERTIFICATE_LAESTANCIA_PART-C_SIGNED-2023-10-26_V1.PDF DOCUMENTS VIEW
LA ESTANCIA CHLORINATION REPORT-2023-08-23_V1.PDF DOCUMENTS VIEW
LA ESTANCIA SPECIAL INSPECTION CERT-2023-08-23_V1.PDF DOCUMENTS VIEW
LA ESTANCIA TEST AND BALANCE_V1.PDF DOCUMENTS VIEW
SPAPP-LA ESTANCIA FRAMING SPECIAL INSPECTION FINAL-2023-08-23_V1.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
2_STRUCTURAL CALCS_V1.PDF DOCUMENTS VIEW
CONS-3_PLAN SET_V1.PDF DOCUMENTS VIEW
CONS-LAE PARCEL 1 APPROVED GRADING PLAN_V1.PDF DOCUMENTS VIEW
CONS-LAESTANCIA PII PARK ARCHITECTURE 09.07.21_V1.PDF DOCUMENTS VIEW
FINAL APPROVED-DP1740_LAE OFFSITE 2- PN.2-027-2021_V1.PDF DOCUMENTS VIEW
LAESTANCIA PII PARK STRUCTURAL CALCS 09.07.21_V1.PDF DOCUMENTS VIEW
T21CM07679-COLLECTIV LANDSCAPE ARCHITECTS-9_20_2021_V1.PDF DOCUMENTS VIEW