Permit: T21CM07671
Permit Details
Status:
Complete
Type:
Residential Building - One or Two Family
Address:
3520 N FLOWING WELLS RD
Address NEW:
3520 N FLOWING WELLS RD
Apply Date:
09/24/2021
Applicant:
Description:
SFR
Permit Reviews
Permit Number - T21CM07671
Permit Status: Complete
Permit Description: SFR
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 09/24/2021 | RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO | 10/19/2021 | COMPLETED |
| 11/18/2021 | RESUBMITTAL | 12/01/2021 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T21CM07671
Permit Status: Complete
Permit Description: SFR
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 11/30/2021 | ROOF TRUSSES MUST BE APPROVED PRIOR TO FRAMING INSPECTION (P2I) |
Completed Inspections
Permit Status: Complete
Permit Number: T21CM07671
Permit Description: SFR
Total Completed Inspections - 20
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/28/2021 | COT - RSPL - Yard Water Line | Passed | {Activity date: 12/28/2021; Status: Approved; Inspector: DQUINN; Comment: Entered by NGARCIA3 - Ap } |
|
| 12/28/2021 | COT - RSPL - Rough Soil | Passed | {Activity date: 12/28/2021; Status: Approved; Inspector: DQUINN; Comment: Entered by NGARCIA3 - Ap} | |
| 01/14/2022 | COT - RSEL - Grounding/Bonding | Passed | {Activity date: 01/14/2022; Status: Approved; Inspector: DQUINN; Comment: Entered by NGARCIA3 - Ap} | |
| 01/14/2022 | COT - RSBU - Preslab | Passed | {Activity date: 01/14/2022; Status: Approved; Inspector: DQUINN; Comment: Entered by NGARCIA3 - Ap} | |
| 01/14/2022 | COT - RSEL - Electrical Underground | Passed | {Activity date: 01/14/2022; Status: Approved; Inspector: DQUINN; Comment: Entered by NGARCIA3 - Ap} | |
| 01/14/2022 | COT - RSBU - Excavation/Rebar/Zoning | Passed | {Activity date: 01/14/2022; Status: Approved; Inspector: DQUINN; Comment: Entered by NGARCIA3 - Ap} | |
| 02/17/2022 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | {Activity date: 02/17/2022; Status: Approved; Inspector: ESTEVENS; Comment: Entered by VVERA1 - Approved} | |
| 02/22/2022 | COT - RSBU - Roof Nailing | Passed | {Activity date: 02/22/2022; Status: Approved; Inspector: ESTEVENS; Comment: Entered by VVERA1 - Approved} ; {Activity date: 02/17/2022; Status: Partial Approval; Inspector: ESTEVENS; Comment: Entered by VVERA1 - Partial. Missing roof truss drawings.} | |
| 03/08/2022 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | {Activity date: 03/08/2022; Status: Approved; Inspector: DQUINN; Comment: Entered by VVERA1 - Ap} | |
| 03/08/2022 | COT - LCBU - Framing | Passed | {Activity date: 03/08/2022; Status: Approved; Inspector: DQUINN; Comment: Entered by VVERA1 - Ap} | |
| 04/04/2022 | PDSD Building Division - TEP PM Clearance | Passed | {Activity date: 04/04/2022; Status: Approved; Inspector: DQUINN; Comment: Entered by VVERA1 - CODE ECO} | |
| 04/04/2022 | COT - LCPL - Plumbing Intermediate | Passed | {Activity date: 04/04/2022; Status: Approved; Inspector: DQUINN; Comment: Entered by VVERA1 - Ap} | |
| 04/04/2022 | COT - RSEL - Construction Power | Passed | {Activity date: 04/04/2022; Status: Approved; Inspector: DQUINN; Comment: Entered by VVERA1 - Ap Clear eco} |
|
| 04/04/2022 | RSME - Mechanical Progress | Passed | {Activity date: 04/04/2022; Status: Approved; Inspector: DQUINN; Comment: Entered by VVERA1 - Ap} | |
| 06/14/2022 | COT - RSPL - Sewer | Passed | {Activity date: 06/14/2022; Status: Approved; Inspector: DQUINN; Comment: Entered by NGARCIA3 - Ap Abs tied to existing Lateral on property.} |
|
| 12/14/2022 | COT - RSEL - Electrical Final | Passed | ||
| 12/14/2022 | RSBU - Building Final | Passed | ||
| 12/14/2022 | COT - RSME - Mechanical Final | Passed | ||
| 12/14/2022 | COT - RSEL - Outdoor Lighting | Passed | ||
| 12/14/2022 | COT - RSPL - Plumbing Final | Passed |