Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Final
Type:
SOLAR WAIVER - RES
Apply Date:
09/15/2021
Applicant:
Technicians for Sustainability
Description:
roof mount 3.0 kW photovoltaic solar system addition to existing 2.7 kW system, 8 modules, add one branch circuit to existing single branch circuit, PV subpanel, 30A PV breaker on 200A bus with 200A MCB
Contractors:
  • Technicians for Sustainability

Permit Reviews

Permit Number - T21CM07449
Permit Status: Final
Permit Description: roof mount 3.0 kW photovoltaic solar system addition to existing 2.7 kW system, 8 modules, add one branch circuit to existing single branch circuit, PV subpanel, 30A PV breaker on 200A bus with 200A MCB
Start Date Submittal Complete Date Status  
09/15/2021 OTHER 10/06/2021 COMPLETED Review Details

Completed Inspections

Permit Status: Final
Permit Number: T21CM07449
Permit Description: roof mount 3.0 kW photovoltaic solar system addition to existing 2.7 kW system, 8 modules, add one branch circuit to existing single branch circuit, PV subpanel, 30A PV breaker on 200A bus with 200A MCB
Total Completed Inspections - 3
Date Description Inspector Results Comments
01/19/2022 TEP CLEARANCE - PM WGALLAGHER Approved CODE DGC
01/19/2022 ELECTRIC - FINAL WGALLAGHER Approved Approved ok for clearance DGC
01/19/2022 BUILDING - FINAL WGALLAGHER Approved Approved

Documents

File Name Document Type  
APPLICATION 2024 MASS-UPLOAD.PDF DOCUMENTS VIEW
JOB CARD 2024 MASS-UPLOAD.PDF DOCUMENTS VIEW
PERMIT 2024 MASS-UPLOAD.PDF DOCUMENTS VIEW
PLAN SET 2024 MASS-UPLOAD.PDF DOCUMENTS VIEW
SPEC SHEETS 2024 MASS-UPLOAD.PDF DOCUMENTS VIEW
APPLICATION.PDF DOCUMENTS VIEW
JOB CARD.PDF DOCUMENTS VIEW
PERMIT.PDF DOCUMENTS VIEW
PLAN SET.PDF DOCUMENTS VIEW
SPEC SHEETS.PDF DOCUMENTS VIEW