Permit: T21CM07445
Permit Details
Status:
Final
Type:
SOLAR WAIVER - RES
Address:
4321 E MONTECITO ST
Address NEW:
4321 E MONTECITO ST
Apply Date:
09/15/2021
Applicant:
Technicians for Sustainability
Description:
roof mount 3.16 kW photovoltaic solar system, 8 modules, 1 branch, 20A PV breaker on 200A bus with 200A MCB
Contractors:
- Technicians for Sustainability
Permit Reviews
Permit Number - T21CM07445
Permit Status: Final
Permit Description: roof mount 3.16 kW photovoltaic solar system, 8 modules, 1 branch, 20A PV breaker on 200A bus with 200A MCB
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 09/15/2021 | OTHER | 10/06/2021 | COMPLETED |
Completed Inspections
Permit Status: Final
Permit Number: T21CM07445
Permit Description: roof mount 3.16 kW photovoltaic solar system, 8 modules, 1 branch, 20A PV breaker on 200A bus with 200A MCB
Total Completed Inspections - 5
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/04/2022 | TEP CLEARANCE - PM | RCHANDLER | Approved | CODE DGC |
| 01/04/2022 | ELECTRIC - FINAL | RCHANDLER | Approved | AP. DGC clearance for TEP. |
| 01/04/2022 | BUILDING - FINAL | RCHANDLER | Approved | AP |
| 01/04/2022 | ELECTRIC - FINAL | RCHANDLER | Approved | -DE. Need address label on meter. |
| 01/04/2022 | BUILDING - FINAL | RCHANDLER | Approved | DE. Need to obtain 2090 inspection approval. |