Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Issued
Type:
Residential Building - One or Two Family
Apply Date:
09/15/2021
Applicant:
Andrea Flood
Description:
SFR STF40K T20-M0039

Outstanding Activity Conditions

Permit Number - T21CM07431
Permit Status: Issued
Permit Description: SFR STF40K T20-M0039
Total Outstanding Activity Conditions - 2
Date Name
09/15/2021 ROOF TRUSSES MUST BE APPROVED PRIOR TO FRAMING INSPECTION (P2I)
09/15/2021 SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED.

Completed Inspections

Permit Status: Issued
Permit Number: T21CM07431
Permit Description: SFR STF40K T20-M0039
Total Completed Inspections - 23
Date Description Inspector Results Comments
11/05/2021 COT - RSPL - Yard Water Line Passed {Activity date: 11/05/2021; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by RSALDAT1 - . AP} ; {Activity date: 11/04/2021; Status: Correction Required; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - CO connect copper to water line}
11/05/2021 COT - RSPL - Sewer Passed {Activity date: 11/05/2021; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by RSALDAT1 - . AP} ; {Activity date: 11/04/2021; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP}
11/05/2021 COT - RSPL - Rough Soil Passed {Activity date: 11/05/2021; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by RSALDAT1 - . AP} ; {Activity date: 11/04/2021; Status: Correction Required; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - CO provide shade material or screen.}
12/23/2021 COT - RSEL - Grounding/Bonding Passed {Activity date: 12/23/2021; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP}
12/23/2021 COT - RSBU - Preslab Passed {Activity date: 12/23/2021; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP}
12/23/2021 COT - RSEL - Electrical Underground Passed {Activity date: 12/23/2021; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP}
12/23/2021 COT - RSBU - Excavation/Rebar/Zoning Passed {Activity date: 12/23/2021; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP}
01/20/2022 COT - RSBU - Roof Nailing Passed {Activity date: 01/20/2022; Status: Approved; Inspector: WGALLAGHER; Comment: Entered by VVERA1 - Approved}
01/20/2022 COT - RSBU - Exterior Clips/Sheathing Passed {Activity date: 01/20/2022; Status: Approved; Inspector: WGALLAGHER; Comment: Entered by VVERA1 - Approved}
03/22/2022 COT - RSPL - Gas Pressure Test Passed {Activity date: 03/22/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - AP} ; {Activity date: 03/17/2022; Status: Not ready for Inspection; Inspector: WGALLAGHER; Comment: Entered by NGARCIA3 - Not ready}
04/18/2022 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed {Activity date: 04/18/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - AP} ; {Activity date: 03/17/2022; Status: Partial Approval; Inspector: WGALLAGHER; Comment: Entered by NGARCIA3 - Partial approval see other intermediates and roof not loaded}
04/18/2022 COT - LCBU - Framing Passed {Activity date: 04/18/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - AP} ; {Activity date: 04/11/2022; Status: Correction Required; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - CO} ; {Activity date: 03/22/2022; Status: Partial Approval; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - PA. Remove all shims at bearing points until after the roof is loaded, than recall framing inspection. NO INSULATION/SHEET ROCK until roof is loaded} ; {Activity date: 03/17/2022; Status: Partial Approval; Inspector: WGALLAGHER; Comment: Entered by NGARCIA3 - Partial approval Header in hall is not per plan, require blocking above at top of truss}
04/18/2022 COT - LCPL - Plumbing Intermediate Passed {Activity date: 04/18/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - AP} ; {Activity date: 04/11/2022; Status: Correction Required; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - CO. Dwv not tested with water} ; {Activity date: 03/17/2022; Status: Partial Approval; Inspector: WGALLAGHER; Comment: Entered by NGARCIA3 - Partial approval pex line on can and in between gas pipe and vent, not under DWV test}
04/18/2022 RSME - Mechanical Progress Passed {Activity date: 04/18/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - AP} ; {Activity date: 04/11/2022; Status: Correction Required; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - CO. Fresh air intake within 10’ of vent stack} ; {Activity date: 03/17/2022; Status: Partial Approval; Inspector: WGALLAGHER; Comment: Entered by NGARCIA3 - Fresh air intake within 10 ft of vent}
05/05/2022 COT - HCBU - Interior Shear Bracing Passed {Activity date: 05/05/2022; Status: Approved; Inspector: WGALLAGHER; Comment: Entered by NGARCIA3 - Approved}
05/13/2022 PDSD Building Division - TEP PM Clearance Passed {Activity date: 05/13/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - CODE ECO}
05/13/2022 COT - RSEL - Construction Power Passed {Activity date: 05/13/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - AP
TEP ECO}
07/22/2022 COT - BULD - SWG Clearance Passed {Activity date: 07/22/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - CODE}
08/02/2022 COT - RSME - Mechanical Final Passed {Activity date: 08/02/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP}
08/02/2022 RSBU - Building Final Passed {Activity date: 08/02/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP}
08/02/2022 COT - RSEL - Outdoor Lighting Passed {Activity date: 08/02/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP}
08/02/2022 COT - RSPL - Plumbing Final Passed {Activity date: 08/02/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP} ; {Activity date: 07/22/2022; Status: Partial Approval; Inspector: TLUNDBERG; Comment: Entered by VVERA1 - PA. SWG clearance required

}
08/02/2022 COT - RSEL - Electrical Final Passed {Activity date: 08/02/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP}

Documents

File Name Document Type  
SPECIAL INSPECTION CERT.PDF DOCUMENTS VIEW
PERMIT.PDF DOCUMENTS VIEW
JOB CARD.PDF DOCUMENTS VIEW
APPLICATION.PDF DOCUMENTS VIEW
SITE PLAN.PDF CONSTRPLANS VIEW