Permit: T21CM07187
Permit Details
Status:
Final
Type:
SINGLE FAMILY ADDITION
Address:
3236 E WAVERLY ST
Address NEW:
3236 E WAVERLY ST
Apply Date:
09/07/2021
Applicant:
Ben Howayeck
Description:
Garage addition, bathroom/bedroom remodel
Architects:
- Joe Hubbard
Contractors:
- BTH Construction
Permit Reviews
Permit Number - T21CM07187
Permit Status: Final
Permit Description: Garage addition, bathroom/bedroom remodel
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 09/07/2021 | RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO | 10/05/2021 | COMPLETED |
Completed Inspections
Permit Status: Final
Permit Number: T21CM07187
Permit Description: Garage addition, bathroom/bedroom remodel
Total Completed Inspections - 16
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/02/2021 | BUILDING PRE-SLAB | JBURGE | Approved | Approved. Ensure slab is termite treated before placing concrete. |
| 11/02/2021 | EXCAVATION/LAYOUT REBAR & ZON | JBURGE | Approved | Approved |
| 11/16/2021 | PLUMBING - ROUGH, SOIL | DQUINN | Approved | Ap |
| 11/16/2021 | ELECTRIC - UFER | DQUINN | Approved | Ap |
| 12/01/2021 | ROOF NAILING | ESTEVENS | Approved | Approved |
| 12/01/2021 | EXT METAL CLIPS/EXT SHEATHING | ESTEVENS | Approved | Approved |
| 12/20/2021 | ELECTRIC - UNDERGROUND | DQUINN | Approved | Ap Under from house to garage ok. |
| 01/05/2022 | TEP CLEARANCE - PM | DQUINN | Approved | CODE INCR/CUTOVER |
| 01/05/2022 | ELECTRIC - SERVICE UPGRADE | DQUINN | Approved | Ap Need cutover for final Clear incr |
| 01/11/2022 | RESIDENTIAL INTERMEDIATE | ESTEVENS | Approved | Approved |
| 07/08/2022 | FRAMING | WGALLAGHER | Approved | Approved |
| 07/19/2022 | ELECTRIC - FINAL | WGALLAGHER | Approved | Approved 1090 |
| 07/19/2022 | MECHANICAL - FINAL | WGALLAGHER | Approved | Approved |
| 07/19/2022 | PLUMBING - FINAL | WGALLAGHER | Approved | Approved |
| 07/19/2022 | OUTDOOR LIGHTING FINAL | WGALLAGHER | Approved | Approved |
| 07/19/2022 | BUILDING - FINAL | WGALLAGHER | Approved | Approved |