Start Date Submittal Complete Date Status  
07/08/2021 RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO 08/18/2021 COMPLETED Review Details
09/21/2021 RESUBMITTAL 09/30/2021 COMPLETED Review Details

Outstanding Inspections

Permit Status: Issued
Permit Number: T21CM05585
Permite Description: Ramada
Total Outstanding Inspections - 3
Last Inspection Date Description Inspector Results Comments
11/04/2022 COT - LCBU - Framing N/A Canceled Inspection Canceled
11/04/2022 COT - RSEL - Electrical Final N/A Canceled Inspection Canceled
11/07/2022 COT - RSPL - Plumbing Final N/A Canceled Inspection Canceled

Completed Inspections

Permit Status: Issued
Permit Number: T21CM05585
Permit Description: Ramada
Total Completed Inspections - 6
Date Description Inspector Results Comments
12/21/2021 COT - RSBU - Excavation/Rebar/Zoning Passed {Activity date: 12/21/2021; Status: Approved; Inspector: RCHANDLER; Comment: Entered by NGARCIA3 - AP}
03/31/2022 COT - RSPL - Gas Pressure Test Passed {Activity date: 03/31/2022; Status: Approved; Inspector: RCHANDLER; Comment: Entered by NGARCIA3 - -AP. No clearance needed.} ; {Activity date: 02/01/2022; Status: Not ready for Inspection; Inspector: RCHANDLER; Comment: Entered by VVERA1 - Sent text at 10:51

After noon.

1:00

1:08; NR. Contractor thought it was an on site inspection; will attempt to get someone with a phone to contact me.

415-806-6286 is on site contact.

1:45

1:49; unable to connect with FaceTime nor Duo.

} ; {Activity date: 01/31/2022; Status: Cancelled; Inspector: RCHANDLER; Comment: Entered by NGARCIA3 - -CA per text from contractor.}
06/14/2023 COT - RSBU - Roof Nailing Passed Metal roof is properly screwed off to roof rafters.
06/14/2023 RSBU - Building Final Passed Ramada, Gas-line connection and electrical outlets being complete.
06/14/2023 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed Column post, beams, purlins, and rafters are properly connected with screws connecting from the top.
06/14/2023 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed Gas line for outdoor fire pit is properly installed and operational. Electrical for ceiling fans and outdoor barbecue island is properly installed with GFCI breakers in electrical panel.

Documents

File Name Document Type  
APPLICATION 2024 MASS-UPLOAD.PDF DOCUMENTS VIEW
JOB CARD 2024 MASS-UPLOAD.PDF DOCUMENTS VIEW
PERMIT 2024 MASS-UPLOAD.PDF DOCUMENTS VIEW
PLAN SET 2024 MASS-UPLOAD.PDF DOCUMENTS VIEW
SPECIAL INSPECTION CERTIFICATE 2024 MASS-UPLOAD.PDF DOCUMENTS VIEW
STRUC CALCS 2024 MASS-UPLOAD.PDF DOCUMENTS VIEW
APPLICATION.PDF DOCUMENTS VIEW
JOB CARD.PDF DOCUMENTS VIEW
PERMIT.PDF DOCUMENTS VIEW