Permit: T21CM05454
Permit Details
Status:
Complete
Type:
Residential Building - One or Two Family
Address:
5059 N WILD LIFE DR
Address NEW:
5059 N WILD LIFE DR
Apply Date:
07/02/2021
Applicant:
Joel Barcelo
Description:
Single Family Residence
Permit Reviews
Permit Number - T21CM05454
Permit Status: Complete
Permit Description: Single Family Residence
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 01/03/2022 | RESUBMITTAL | 01/25/2022 | COMPLETED |
| 04/11/2022 | RESUBMITTAL | 05/17/2022 | COMPLETED |
| 07/02/2021 | RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO | 08/04/2021 | COMPLETED |
Conditions
Permit Number - T21CM05454
Permit Status: Complete
Permit Description: Single Family Residence
| Date | Description | Comments |
|---|---|---|
| 07/28/2021 | ROOF TRUSSES MUST BE APPROVED PRIOR TO FRAMING INSPECTION (P2I) |
Outstanding Inspections
Permit Status: Complete
Permit Number: T21CM05454
Permite Description: Single Family Residence
Total Outstanding Inspections - 2
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/26/2022 | COT - RSBU - Stem Wall/Retaining Wall | N/A | Not Ready | |
| 10/26/2022 | COT - RSPL - Sewer | N/A | Not Ready |
Completed Inspections
Permit Status: Complete
Permit Number: T21CM05454
Permit Description: Single Family Residence
Total Completed Inspections - 21
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/07/2022 | COT - RSPL - Yard Water Line | Passed | {Activity date: 06/07/2022; Status: Approved; Inspector: DQUINN; Comment: Entered by NGARCIA3 - Ap} | |
| 06/07/2022 | COT - RSPL - Rough Soil | Passed | {Activity date: 06/07/2022; Status: Approved; Inspector: DQUINN; Comment: Entered by NGARCIA3 - Ap} | |
| 06/22/2022 | COT - RSEL - Grounding/Bonding | Passed | {Activity date: 06/22/2022; Status: Approved; Inspector: DQUINN; Comment: Entered by VVERA1 - Ap} | |
| 06/22/2022 | COT - RSBU - Preslab | Passed | {Activity date: 06/22/2022; Status: Approved; Inspector: DQUINN; Comment: Entered by VVERA1 - Ap} | |
| 06/22/2022 | COT - RSEL - Electrical Underground | Passed | {Activity date: 06/22/2022; Status: Approved; Inspector: DQUINN; Comment: Entered by VVERA1 - Ap} | |
| 06/22/2022 | COT - RSBU - Excavation/Rebar/Zoning | Passed | {Activity date: 06/22/2022; Status: Approved; Inspector: DQUINN; Comment: Entered by VVERA1 - Ap} ; {Activity date: 06/07/2022; Status: Not ready for Inspection; Inspector: DQUINN; Comment: Entered by NGARCIA3 - nr} | |
| 07/28/2022 | COT - RSBU - Roof Nailing | Passed | {Activity date: 07/28/2022; Status: Approved; Inspector: ESTEVENS; Comment: Entered by NGARCIA3 - Approved} | |
| 07/28/2022 | PDSD Building Division - TEP PM Clearance | Passed | {Activity date: 07/28/2022; Status: Approved; Inspector: ESTEVENS; Comment: Entered by NGARCIA3 - CODE ECO} | |
| 07/28/2022 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | {Activity date: 07/28/2022; Status: Approved; Inspector: ESTEVENS; Comment: Entered by NGARCIA3 - Approved} | |
| 07/28/2022 | COT - RSEL - Construction Power | Passed | {Activity date: 07/28/2022; Status: Approved; Inspector: ESTEVENS; Comment: Entered by NGARCIA3 - Approved. The TEP clearance code is ECO.} | |
| 09/08/2022 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | {Activity date: 09/08/2022; Status: Approved; Inspector: RCHANDLER; Comment: Entered by NGARCIA3 - Approved} | |
| 09/08/2022 | COT - LCPL - Plumbing Intermediate | Passed | {Activity date: 09/08/2022; Status: Approved; Inspector: RCHANDLER; Comment: Entered by NGARCIA3 - Approved} | |
| 09/08/2022 | RSME - Mechanical Progress | Passed | {Activity date: 09/08/2022; Status: Approved; Inspector: RCHANDLER; Comment: Entered by NGARCIA3 - Approved} | |
| 09/08/2022 | COT - RSPL - Gas Pressure Test | Passed | {Activity date: 09/08/2022; Status: Approved; Inspector: RCHANDLER; Comment: Entered by NGARCIA3 - Approved} | |
| 09/15/2022 | COT - LCBU - Framing | Passed | {Activity date: 09/15/2022; Status: Approved; Inspector: WGALLAGHER; Comment: Entered by NGARCIA3 - Approved} | |
| 09/20/2022 | COT - HCBU - Interior Shear Bracing | Passed | {Activity date: 09/20/2022; Status: Approved; Inspector: ESTEVENS; Comment: Entered by NGARCIA3 - Approved} | |
| 12/07/2022 | COT - RSPL - Plumbing Final | Passed | ||
| 12/07/2022 | COT - RSEL - Outdoor Lighting | Passed | ||
| 12/07/2022 | COT - RSME - Mechanical Final | Passed | ||
| 12/07/2022 | COT - RSEL - Electrical Final | Passed | ||
| 12/07/2022 | RSBU - Building Final | Passed |