Permit Details

Status:
Complete
Type:
Commercial Building
Apply Date:
07/01/2021
Applicant:
Samuel Lopez
Description:
building addition and interior remodel for a gym that services the office tenants at 5210, 5255 & 52

Permit Reviews

Permit Number - T21CM05438
Permit Status: Complete
Permit Description: building addition and interior remodel for a gym that services the office tenants at 5210, 5255 & 52
Start Date Submittal Complete Date Status  
06/10/2022 RESUBMITTAL 06/27/2022 COMPLETED Review Details
07/01/2021 COMMERCIAL - BLDG/FIRE/ZONING/ENG 08/24/2021 COMPLETED Review Details
07/09/2024 BUILDING DEFERRED SUBMITTAL REVIEW v.1 07/11/2024 APPROVED Review Details
07/11/2024 BUILDING DEFERRED SUBMITTAL REVIEW v.1 07/17/2024 APPROVED Review Details
07/02/2024 BUILDING DEFERRED SUBMITTAL REVIEW v.1 07/02/2024 APPROVED Review Details

Conditions

Permit Number - T21CM05438
Permit Status: Complete
Permit Description: building addition and interior remodel for a gym that services the office tenants at 5210, 5255 & 52
Date Description Comments
07/02/2024 AIR BALANCING REPORT IS REQUIRED.
06/26/2024 SPECIAL INSPECTION FOR CONCRETE INSTALLATION IS REQUIRED.
07/02/2024 DECKING SHOT PINS
07/02/2024
06/26/2024 Plan review applications expire 180 days from date of submittal unless the permit has been issued. Permits expire 180 days after issuance or last approved inspection.
06/26/2024 SPECIAL INSPECTION FOR FIELD WELDING IS REQUIRED.
06/26/2024 SPECIAL INSPECTION FOR HIGH STRENGTH BOLTING IS REQUIRED.
07/02/2024 SPECIAL INSPECTION FOR REINFORCING STEEL AND/OR PRE-STRESSING TENDONS IS REQUIRED.
06/26/2024 SHOP WELDING - SPECIAL INSPECTION FOR STRUCTURAL WELDING IS REQUIRED.
06/26/2024 Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building.
07/02/2024 WATER STERILIZATION REPORT IS REQUIRED.
06/26/2024 SPECIAL INSPECTION FOR WELD REINF STEEL IS REQUIRED.

Outstanding Inspections

Permit Status: Complete
Permit Number: T21CM05438
Permite Description: building addition and interior remodel for a gym that services the office tenants at 5210, 5255 & 52
Total Outstanding Inspections - 7
Last Inspection Date Description Inspector Results Comments
09/26/2023 COT - LCBU - Building Progress N/A Not Applicable
09/26/2023 COT - LCEL - Electrical Progress N/A Not Applicable
11/30/2023 COT - LCPL - Gas Pressure Test N/A Not Applicable 11/30/23: no gas in building
12/07/2022 COT - LCBU - Preslab N/A Partial Pass Addition only.
COT - FCON - Sprinkler - Final N/A Not Ready
COT - FCON - Alarm - Final N/A Not Ready
06/10/2024 COT - FCON - Fire - Final N/A Partial Pass Address, EM lights in yoga room.

Completed Inspections

Permit Status: Complete
Permit Number: T21CM05438
Permit Description: building addition and interior remodel for a gym that services the office tenants at 5210, 5255 & 52
Total Completed Inspections - 23
Date Description Inspector Results Comments
12/07/2022 COT - LCBU - Excavation/Rebar/Zoning Passed
09/26/2023 COT - LCEL - Electrical Intermediate Passed
09/26/2023 COT - LCBU - Exterior Clips/Sheathing Passed
09/29/2023 COT - LCBU - Framing Passed 5-9-23: Parapet and exterior walls of equipment room.
9/26/23: install all anchor nuts and washers, clean out track
9/29/23: all framing complete.
11/16/2023 COT - LCEL - Electrical Underground Passed
11/16/2023 COT - LCBU - Roof Nailing Passed
11/30/2023 COT - LCPL - Plumbing Intermediate Passed
11/30/2023 COT - LCBU - Preslab Passed 11/30/23: restrooms showers plumbing to plan okay to backfill and place concrete
12/20/2023 COT - LCME - Mechanical Above Ceiling Passed 12-20-23: HVAC ductwork, register covers, and units are installed for exercise room, lobby area, and basketball court.
12/20/2023 COT - HCBU - Interior Shear Bracing Passed 12-20-23: Interior shear walls are complete and meet plan requirements. Okay to tape, texture, and paint all walls.
12/20/2023 COT - LCME - Mechanical Intermediate Passed 12-20-23: HVAC ductwork, register covers, and units are installed for exercise room, lobby area, and basketball court.
05/30/2024 COT - LCPL - Plumbing Final Passed
05/30/2024 COT - LCME - Mechanical Final Passed
05/30/2024 COT - LCPL - Plumbing Above Ceiling Passed
05/30/2024 COT - LCME - Mechanical Progress Passed
05/30/2024 COT - LCBU - Sustainability Passed
05/30/2024 COT - LCPL - Plumbing Progress Passed
05/30/2024 COT - LCBU - Building Above Ceiling Passed
05/30/2024 COT - LCEL - Outdoor Lighting Passed
05/30/2024 COT - LCEL - Electrical Final Passed
05/30/2024 BULD - Electrical Clearance Passed
06/10/2024 COT - LCBU - Building Final Passed
06/20/2024 COT - FCON - Fire - Final Passed

Documents

File Name Document Type  
COFO_FINALCOFO_COMMERCIAL.PDF DOCUMENTS VIEW
SOILS SPECIAL INSPECTION MEMO 7-19-24-2024-07-19_V1.PDF DOCUMENTS VIEW
SPECIAL INSPECTION MEMO 7-10-24-2024-07-11_V1.PDF DOCUMENTS VIEW
WILLIAMS CENTER GYM SPECIAL INSPECTION 7-9-24_V1.PDF DOCUMENTS VIEW
21015 - SUPPLEMENTAL CALC, JOISTS - 07-08-24_V1.PDF DOCUMENTS VIEW
21-080M WILLIAMS CENTER GYM SPL. IN. PACKAGE FINAL-2024-07-02_V1.PDF DOCUMENTS VIEW
24F0563_1 TURNER 06 25 2024 1307-2024-07-02_V1.PDF DOCUMENTS VIEW
WILLIAMSCENTERGYM_V1.PDF DOCUMENTS VIEW
AIR SYSTEM SIZING.PDF DOCUMENTS VIEW
APPLICATION.PDF DOCUMENTS VIEW
JOB CARD.PDF DOCUMENTS VIEW
LETTER OF INTENT (1).PDF DOCUMENTS VIEW
MECHANICAL COMCHECK.PDF DOCUMENTS VIEW
PERMIT.PDF DOCUMENTS VIEW
PLAN SET.PDF DOCUMENTS VIEW
STRUC CALCS.PDF DOCUMENTS VIEW
YEARLY BOND EXP 07312022.PDF DOCUMENTS VIEW