Permit: T21CM04865
Permit Details
Status:
Expired
Type:
Residential Building - One or Two Family
Address:
6305 S DESERT PEAK DR
Address NEW:
6305 S DESERT PEAK DR
Apply Date:
06/10/2021
Applicant:
Description:
SFR LENNVC452 T20-M0035
Outstanding Activity Conditions
Permit Number - T21CM04865
Permit Status: Expired
Permit Description: SFR LENNVC452 T20-M0035
Total Outstanding Activity Conditions - 3
| Date | Name |
|---|---|
| 06/10/2021 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
| 06/10/2021 | ROOF TRUSSES MUST BE APPROVED PRIOR TO FRAMING INSPECTION (P2I) |
| 06/10/2021 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. |
Completed Inspections
Permit Status: Expired
Permit Number: T21CM04865
Permit Description: SFR LENNVC452 T20-M0035
Total Completed Inspections - 21
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/16/2021 | COT - RSPL - Yard Water Line | Passed | {Activity date: 07/16/2021; Status: Approved; Inspector: DMUNIZ; Comment: Entered by RSALDAT1 - Approved} | |
| 07/16/2021 | COT - RSPL - Sewer | Passed | {Activity date: 07/16/2021; Status: Approved; Inspector: DMUNIZ; Comment: Entered by RSALDAT1 - Approved} | |
| 07/16/2021 | COT - RSPL - Rough Soil | Passed | {Activity date: 07/16/2021; Status: Approved; Inspector: DMUNIZ; Comment: Entered by RSALDAT1 - Approved} | |
| 08/16/2021 | COT - RSEL - Grounding/Bonding | Passed | {Activity date: 08/16/2021; Status: Approved; Inspector: DMUNIZ; Comment: Entered by VVERA1 - Approved} | |
| 08/16/2021 | COT - RSBU - Preslab | Passed | {Activity date: 08/16/2021; Status: Approved; Inspector: DMUNIZ; Comment: Entered by VVERA1 - Approved} | |
| 08/16/2021 | COT - RSEL - Electrical Underground | Passed | {Activity date: 08/16/2021; Status: Approved; Inspector: DMUNIZ; Comment: Entered by VVERA1 - Approved} | |
| 08/16/2021 | COT - RSBU - Excavation/Rebar/Zoning | Passed | {Activity date: 08/16/2021; Status: Approved; Inspector: DMUNIZ; Comment: Entered by VVERA1 - Approved} | |
| 09/01/2021 | COT - RSBU - Roof Nailing | Passed | {Activity date: 09/01/2021; Status: Approved; Inspector: DMUNIZ; Comment: Entered by VVERA1 - Approved} ; {Activity date: 08/26/2021; Status: Not ready for Inspection; Inspector: TGAUSP; Comment: Entered by RSALDAT1 - NR, cancelled by Contractor} | |
| 09/01/2021 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | {Activity date: 09/01/2021; Status: Approved; Inspector: DMUNIZ; Comment: Entered by VVERA1 - Approved} ; {Activity date: 08/26/2021; Status: Not ready for Inspection; Inspector: TGAUSP; Comment: Entered by RSALDAT1 - NR, cancelled by Contractor} | |
| 12/09/2021 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | {Activity date: 12/09/2021; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP} | |
| 12/09/2021 | COT - LCBU - Framing | Passed | {Activity date: 12/09/2021; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP} | |
| 12/09/2021 | COT - RSPL - Gas Pressure Test | Passed | {Activity date: 12/09/2021; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP} | |
| 12/15/2021 | PDSD Building Division - TEP PM Clearance | Passed | {Activity date: 12/15/2021; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - CODE ECO} | |
| 12/15/2021 | COT - RSEL - Construction Power | Passed | {Activity date: 12/15/2021; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP TEP ECO} |
|
| 12/21/2021 | COT - HCBU - Interior Shear Bracing | Passed | {Activity date: 12/21/2021; Status: Approved; Inspector: DMUNIZ; Comment: Entered by RSALDAT1 - Approved} | |
| 03/09/2022 | COT - BULD - SWG Clearance | Passed | {Activity date: 03/09/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - CODE GAS} | |
| 03/21/2022 | COT - RSME - Mechanical Final | Passed | {Activity date: 03/21/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP} | |
| 03/21/2022 | RSBU - Building Final | Passed | {Activity date: 03/21/2022; Status: Partial Approval; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - APPROVED BY INSPECTOR AWAITING CONDITIONS} ; {Activity date: 03/21/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP} | |
| 03/21/2022 | COT - RSEL - Outdoor Lighting | Passed | {Activity date: 03/21/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP} | |
| 03/21/2022 | COT - RSPL - Plumbing Final | Passed | {Activity date: 03/21/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP} ; {Activity date: 03/09/2022; Status: Partial Approval; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - . PA SWG clearance required} |
|
| 03/21/2022 | COT - RSEL - Electrical Final | Passed | {Activity date: 03/21/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP} |