Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Permit Details

Status:
Expired
Type:
Residential Building - One or Two Family
Address NEW:
6275 S DEER PARK LN
Apply Date:
06/09/2021
Applicant:
Description:
SFR LENNVC353 T20-M0033

Outstanding Activity Conditions

Permit Number - T21CM04809
Permit Status: Expired
Permit Description: SFR LENNVC353 T20-M0033
Total Outstanding Activity Conditions - 3
Date Name
06/09/2021 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.
06/09/2021 ROOF TRUSSES MUST BE APPROVED PRIOR TO FRAMING INSPECTION (P2I)
06/09/2021 SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED.

Completed Inspections

Permit Status: Expired
Permit Number: T21CM04809
Permit Description: SFR LENNVC353 T20-M0033
Total Completed Inspections - 24
Date Description Inspector Results Comments
08/10/2021 COT - RSPL - Yard Water Line Passed {Activity date: 08/10/2021; Status: Approved; Inspector: DMUNIZ; Comment: Entered by RSALDAT1 - Approved}
08/10/2021 COT - RSPL - Sewer Passed {Activity date: 08/10/2021; Status: Approved; Inspector: DMUNIZ; Comment: Entered by RSALDAT1 - Approved}
08/10/2021 COT - RSPL - Rough Soil Passed {Activity date: 08/10/2021; Status: Approved; Inspector: DMUNIZ; Comment: Entered by RSALDAT1 - Approved}
09/01/2021 COT - RSEL - Grounding/Bonding Passed {Activity date: 09/01/2021; Status: Approved; Inspector: DMUNIZ; Comment: Entered by VVERA1 - Approved}
09/01/2021 COT - RSBU - Preslab Passed {Activity date: 09/01/2021; Status: Approved; Inspector: DMUNIZ; Comment: Entered by VVERA1 - Approved}
09/01/2021 COT - RSEL - Electrical Underground Passed {Activity date: 09/01/2021; Status: Approved; Inspector: DMUNIZ; Comment: Entered by VVERA1 - Approved}
09/01/2021 COT - RSBU - Excavation/Rebar/Zoning Passed {Activity date: 09/01/2021; Status: Approved; Inspector: DMUNIZ; Comment: Entered by VVERA1 - Approved}
09/17/2021 COT - RSBU - Roof Nailing Passed {Activity date: 09/17/2021; Status: Approved; Inspector: DMUNIZ; Comment: Entered by NGARCIA3 - Approved}
09/17/2021 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed {Activity date: 09/17/2021; Status: Approved; Inspector: DMUNIZ; Comment: Entered by NGARCIA3 - Approved}
12/28/2021 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed {Activity date: 12/28/2021; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP} ; {Activity date: 12/23/2021; Status: Denied; Inspector: DMUNIZ; Comment: Entered by NGARCIA3 - DENIED, see previous corrections.} ; {Activity date: 12/21/2021; Status: Partial Approval; Inspector: DMUNIZ; Comment: Entered by RSALDAT1 - Partial, see notes.}
12/28/2021 COT - LCBU - Framing Passed {Activity date: 12/28/2021; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP} ; {Activity date: 12/23/2021; Status: Denied; Inspector: DMUNIZ; Comment: Entered by NGARCIA3 - Denied, see previous corrections.} ; {Activity date: 12/21/2021; Status: Correction Required; Inspector: DMUNIZ; Comment: Entered by RSALDAT1 - Corrections required, Fire Seal all chase locations.}
12/28/2021 COT - LCPL - Plumbing Intermediate Passed {Activity date: 12/28/2021; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP} ; {Activity date: 12/23/2021; Status: Denied; Inspector: DMUNIZ; Comment: Entered by NGARCIA3 - DENIED, See previous corrections, repair leak at tub above living area.} ; {Activity date: 12/21/2021; Status: Correction Required; Inspector: DMUNIZ; Comment: Entered by RSALDAT1 - Corrections required, strap water lines every 4’.}
12/28/2021 RSEL - Electrical Progress Passed {Activity date: 12/28/2021; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP}
12/28/2021 RSME - Mechanical Progress Passed {Activity date: 12/28/2021; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP} ; {Activity date: 12/23/2021; Status: Denied; Inspector: DMUNIZ; Comment: Entered by NGARCIA3 - DENIED, see previous corrections.} ; {Activity date: 12/21/2021; Status: Partial Approval; Inspector: DMUNIZ; Comment: Entered by RSALDAT1 - Partial, Secure mechanical flex above garage ceiling.}
12/28/2021 COT - RSPL - Gas Pressure Test Passed {Activity date: 12/28/2021; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - AP} ; {Activity date: 12/23/2021; Status: Approved; Inspector: DMUNIZ; Comment: Entered by NGARCIA3 - Approved} ; {Activity date: 12/22/2021; Status: Not ready for Inspection; Inspector: DMUNIZ; Comment: Entered by NGARCIA3 - Not Ready} ; {Activity date: 12/21/2021; Status: Correction Required; Inspector: DMUNIZ; Comment: Entered by RSALDAT1 - correction required, pressurize gas piping system.}
01/05/2022 COT - HCBU - Interior Shear Bracing Passed {Activity date: 01/05/2022; Status: Approved; Inspector: DMUNIZ; Comment: Entered by VVERA1 - approved}
02/16/2022 PDSD Building Division - TEP PM Clearance Passed {Activity date: 02/16/2022; Status: Approved; Inspector: DMUNIZ; Comment: Entered by NGARCIA3 - CODE ECO}
02/16/2022 COT - RSEL - Construction Power Passed {Activity date: 02/16/2022; Status: Approved; Inspector: DMUNIZ; Comment: Entered by NGARCIA3 - Approved clear TEP ECO}
03/14/2022 COT - BULD - SWG Clearance Passed {Activity date: 03/14/2022; Status: Approved; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - CODE GAS}
03/29/2022 COT - RSME - Mechanical Final Passed {Activity date: 03/29/2022; Status: Approved; Inspector: DMUNIZ; Comment: Entered by NGARCIA3 - Approved}
03/29/2022 RSBU - Building Final Passed {Activity date: 03/29/2022; Status: Partial Approval; Inspector: DMUNIZ; Comment: Entered by NGARCIA3 - APPROVED BY INSPECTOR AWAITING CONDITIONS} ; {Activity date: 03/29/2022; Status: Approved; Inspector: DMUNIZ; Comment: Entered by NGARCIA3 - Approved}
03/29/2022 COT - RSEL - Outdoor Lighting Passed {Activity date: 03/29/2022; Status: Approved; Inspector: DMUNIZ; Comment: Entered by NGARCIA3 - Approved 2090}
03/29/2022 COT - RSPL - Plumbing Final Passed {Activity date: 03/29/2022; Status: Approved; Inspector: DMUNIZ; Comment: Entered by NGARCIA3 - Approved} ; {Activity date: 03/14/2022; Status: Partial Approval; Inspector: TLUNDBERG; Comment: Entered by NGARCIA3 - PA
SWG clearance required.}
03/29/2022 COT - RSEL - Electrical Final Passed {Activity date: 03/29/2022; Status: Approved; Inspector: DMUNIZ; Comment: Entered by NGARCIA3 - Approved}