Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
L of c
Type:
COMMERCIAL ADDITION
Address:
3350 E WESTCO PL
Address NEW:
3350 E WESTCO PL
Apply Date:
05/11/2021
Applicant:
VORTEX ENGINEERING, INC.
Description:
Construction of Loading Docks - 3 Pier Docks each 132' in length at existing FedEx package handling facility
Contractors:
  • RIO WEST DEVELOPMENT AND CONSTR *C*

Permit Reviews

Permit Number - T21CM03996
Permit Status: L of c
Permit Description: Construction of Loading Docks - 3 Pier Docks each 132' in length at existing FedEx package handling facility
Start Date Submittal Complete Date Status  
05/11/2021 COMMERCIAL - BLDG/FIRE/ZONING/ENG 06/17/2021 COMPLETED Review Details
06/24/2021 RESUBMITTAL 07/19/2021 COMPLETED Review Details
07/27/2021 RESUBMITTAL 08/09/2021 COMPLETED Review Details
09/24/2021 REVISION - - 1ST 09/27/2021 COMPLETED Review Details
10/11/2021 RESUBMITTAL 10/13/2021 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T21CM03996
Permit Status: L of c
Permit Description: Construction of Loading Docks - 3 Pier Docks each 132' in length at existing FedEx package handling facility
Total Outstanding Activity Conditions - 1
Date Name
05/11/2021 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: L of c
Permit Number: T21CM03996
Permit Description: Construction of Loading Docks - 3 Pier Docks each 132' in length at existing FedEx package handling facility
Total Completed Inspections - 26
Date Description Inspector Results Comments
08/20/2021 BUILDING - PROGRESS DMUNIZ Approved Partial, dowel set for pier 2 ok to proceed.

7050 S PALO VERDE RD
08/20/2021 BUILDING - PROGRESS DMUNIZ Approved Partial, dowel set for pier 2 ok to proceed

3350 E WESTCO PL
08/27/2021 ELECTRIC - INTERMEDIATE DMUNIZ Approved Partial, Underground conduits installed North parking lot, ok to backfill progress.

3350 E WESTCO PL
08/27/2021 ELECTRIC - INTERMEDIATE DMUNIZ Approved Partial, Underground conduits installed North parking lot, ok to backfill progress.
09/09/2021 ELECTRIC - OUTDOOR LIGHTING DMUNIZ Approved Approved
7050 S PALO VERDE RD
09/09/2021 ELECTRIC - OUTDOOR LIGHTING DMUNIZ Approved Approved
3350 E WESTCO PL
10/05/2021 FRAMING TGAUSP Approved Approved for all 3 Piers, rough frame inspection complete, continuous sheathing on both sides of walls (typ)
* T21CM03996 has 2 addresses - 3350 E Westco Pl and 7050 S PALO Verde*
10/05/2021 FRAMING TGAUSP Approved Approved for all 3 Piers, rough frame inspection complete, continuous sheathing on both sides of walls (typ)
* T21CM03996 has 2 addresses - 3350 E Westco Pl and 7050 S PALO Verde*
10/18/2021 BUILDING PRE-SLAB DMUNIZ Approved Approved
10/18/2021 BUILDING ABOVE CEILING DMUNIZ Approved Approved
10/29/2021 NPPO - FINAL DROBERTS Approved IS APPROVED
7050 S PALO VERDE RD
10/29/2021 SIGN - FINAL DROBERTS Approved IS APPROVED
7050 S PALO VERDE RD
10/29/2021 LANDSCAPE - FINAL DROBERTS Approved IS APPROVED
7050 S PALO VERDE RD
10/29/2021 ENGINEERING - FINAL DROBERTS Approved IS APPROVED
7050 S PALO VERDE RD
10/29/2021 ENGINEERING - FINAL DROBERTS Approved IS APPROVED
3350 E WESTCO PL
10/29/2021 LANDSCAPE - FINAL DROBERTS Approved IS APPROVED
3350 E WESTCO PL
10/29/2021 SIGN - FINAL DROBERTS Approved IS APPROVED
3350 E WESTCO PL
10/29/2021 NPPO - FINAL DROBERTS Approved IS APPROVED
3350 E WESTCO PL
10/29/2021 ELECTRIC - PROGRESS DMUNIZ Approved Approved
3350 E WESTCO PL
10/29/2021 ELECTRIC - PROGRESS DMUNIZ Approved Approved
7050 S PALO VERDE RD
11/03/2021 BUILDING - FINAL TGAUSP Approved Partial, pending Fire approval
11/03/2021 ELECTRIC - FINAL TGAUSP Approved - Approved
11/03/2021 OUTDOOR LIGHTING FINAL TGAUSP Approved - Approved
11/03/2021 FIRE - FINAL jfordney Approved Only waiting on under conveyor coverage.
OK for TCO.
Firewatch is not required because piers are constantly attended when in use. Each pier has 2 fire extinguishers and a fully funtioning overhead sprinkler system
11/03/2021 FIRE SPKLR - FINAL jfordney Approved Only waiting on under conveyor cocerage
03/01/2022 RIGHT OF WAY - FINAL jcazare1 Approved no right of way impact approved

Documents

File Name Document Type  
APPLICATION 2024 MASS-UPLOAD.PDF DOCUMENTS VIEW
COMM CHECKLIST 2024 MASS-UPLOAD.PDF DOCUMENTS VIEW
GCL 2024 MASS-UPLOAD.PDF DOCUMENTS VIEW
JOB CARD 2024 MASS-UPLOAD.PDF DOCUMENTS VIEW
PERMIT 2024 MASS-UPLOAD.PDF DOCUMENTS VIEW
PLAN SET 2024 MASS-UPLOAD.PDF DOCUMENTS VIEW
REV1_JOB CARD 2024 MASS-UPLOAD.PDF DOCUMENTS VIEW
REV1_PERMIT 2024 MASS-UPLOAD.PDF DOCUMENTS VIEW
REV1_STRUCTURAL CALCS 2024 MASS-UPLOAD.PDF DOCUMENTS VIEW
REVISION APPLICATION 2024 MASS-UPLOAD.PDF DOCUMENTS VIEW
SPECIAL-INSPECTION-CERTIFICATE COT-WELDING T21CM03996 2024 MASS-UPLOAD.PDF DOCUMENTS VIEW
STRUC CALCS 2024 MASS-UPLOAD.PDF DOCUMENTS VIEW
T21CM03996 - LOFC 2024 MASS-UPLOAD.PDF DOCUMENTS VIEW
APPLICATION.PDF DOCUMENTS VIEW
COMM CHECKLIST.PDF DOCUMENTS VIEW
GCL.PDF DOCUMENTS VIEW
JOB CARD.PDF DOCUMENTS VIEW
PERMIT.PDF DOCUMENTS VIEW
PLAN SET.PDF DOCUMENTS VIEW
REV1_JOB CARD.PDF DOCUMENTS VIEW
REV1_PERMIT.PDF DOCUMENTS VIEW
REV1_STRUCTURAL CALCS.PDF DOCUMENTS VIEW
REVISION APPLICATION.PDF DOCUMENTS VIEW
SPECIAL-INSPECTION-CERTIFICATE COT-WELDING T21CM03996.PDF DOCUMENTS VIEW
STRUC CALCS.PDF DOCUMENTS VIEW
T21CM03996 - LOFC.PDF DOCUMENTS VIEW