Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T21CM03114
Permit Details
Apply Date:
04/12/2021
Applicant:
Annette Suarez / Eglin+Bresler Architects, P.C.
Description:
DENTAL OFFICE
Architects:
- Evan S Eglin
Contractors:
- Camwest Group, Inc.
Permit Reviews
Permit Number - T21CM03114
Permit Status: C of o
Permit Description: DENTAL OFFICE
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
04/12/2021 | COMMERCIAL - TI | 05/06/2021 | COMPLETED |
05/10/2021 | RESUBMITTAL | 05/18/2021 | ACTIVE |
Completed Inspections
Permit Status: C of o
Permit Number: T21CM03114
Permit Description: DENTAL OFFICE
Total Completed Inspections - 22
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/15/2021 | BUILDING PRE-SLAB | WGALLAGHER | Approved | APPROVED INSIDE BUILDING |
06/18/2021 | ELECTRIC - INTERMEDIATE | WGALLAGHER | Approved | |
07/13/2021 | ELECTRIC - PROGRESS | WGALLAGHER | Approved | Approved |
07/13/2021 | PLUMBING - PROGRESS | WGALLAGHER | Approved | Approved |
07/13/2021 | MECHANICAL - PROGRESS | WGALLAGHER | Approved | Approved |
07/26/2021 | TEP CLEARANCE - PM | DMUNIZ | Approved | CODE ECO/ STE 126 |
07/26/2021 | ELECTRIC - CONSTRUCTION POWER | DMUNIZ | Approved | APPROVED, Clear TEP ECO Suite 126 |
08/19/2021 | BUILDING ABOVE CEILING | WGALLAGHER | Approved | Approved |
08/19/2021 | ELECTRIC - ABOVE CEILING | WGALLAGHER | Approved | Approved |
08/19/2021 | PLUMBING - ABOVE CEILING | WGALLAGHER | Approved | Approved |
08/19/2021 | MECHANICAL - INTERMEDIATE | WGALLAGHER | Approved | Approved |
08/19/2021 | MECHANICAL - ABOVE CEILING | WGALLAGHER | Approved | Approved |
09/14/2021 | FIRE SPKLR - FINAL | jfordney | Approved | |
09/17/2021 | FRAMING | WGALLAGHER | Approved | Approved 1090 |
09/17/2021 | SHEET ROCK NAILING | WGALLAGHER | Approved | Approved 1090 |
09/17/2021 | BUILDING - PROGRESS | WGALLAGHER | Approved | Approved 1090 |
09/17/2021 | PLUMBING - INTERMEDIATE | WGALLAGHER | Approved | Approved 3090 |
09/17/2021 | MECHANICAL - FINAL | WGALLAGHER | Approved | Approved |
09/17/2021 | PLUMBING - FINAL | WGALLAGHER | Approved | Approved |
09/17/2021 | ELECTRIC - FINAL | WGALLAGHER | Approved | Approved |
09/22/2021 | FIRE - FINAL | jfordney | Approved | |
09/27/2021 | BUILDING - FINAL | DMUNIZ | Approved | Approved |