SFR LENNVC354 T20-M0030
Outstanding Activity Conditions
Permit Number - T21CM02943
Permit Status: Expired
Permit Description: SFR LENNVC354 T20-M0030
Total Outstanding Activity Conditions - 2
Date | Name |
---|---|
04/06/2021 | ROOF TRUSSES MUST BE APPROVED PRIOR TO FRAMING INSPECTION (P2I) |
04/06/2021 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. |
Completed Inspections
Permit Status: Expired
Permit Number: T21CM02943
Permit Description: SFR LENNVC354 T20-M0030
Total Completed Inspections - 23
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/29/2021 | COT - RSPL - Yard Water Line | Passed | {Activity date: 04/29/2021; Status: Approved; Inspector: DMUNIZ; Comment: Entered by VLEON1 - } | |
04/29/2021 | COT - RSPL - Sewer | Passed | {Activity date: 04/29/2021; Status: Approved; Inspector: DMUNIZ; Comment: Entered by VLEON1 - } | |
04/29/2021 | COT - RSPL - Rough Soil | Passed | {Activity date: 04/29/2021; Status: Approved; Inspector: DMUNIZ; Comment: Entered by VLEON1 - } | |
06/02/2021 | COT - RSEL - Grounding/Bonding | Passed | {Activity date: 06/02/2021; Status: Approved; Inspector: DMUNIZ; Comment: Entered by VLEON1 - } | |
06/02/2021 | COT - RSBU - Preslab | Passed | {Activity date: 06/02/2021; Status: Approved; Inspector: DMUNIZ; Comment: Entered by VLEON1 - } | |
06/02/2021 | COT - RSEL - Electrical Underground | Passed | {Activity date: 06/02/2021; Status: Approved; Inspector: DMUNIZ; Comment: Entered by VLEON1 - } | |
06/02/2021 | COT - RSBU - Excavation/Rebar/Zoning | Passed | {Activity date: 06/02/2021; Status: Approved; Inspector: DMUNIZ; Comment: Entered by VLEON1 - } | |
06/30/2021 | COT - RSBU - Roof Nailing | Passed | {Activity date: 06/30/2021; Status: Approved; Inspector: DMUNIZ; Comment: Entered by VLEON1 - Note: install nuts at back patio sill plate where missing, continue nailing gable end truss to top plate.} | |
06/30/2021 | COT - RSBU - Exterior Clips/Sheathing | Passed | {Activity date: 06/30/2021; Status: Approved; Inspector: DMUNIZ; Comment: Entered by VLEON1 - Note: install nuts at back patio sill plate where missing, continue nailing gable end truss to top plate.} | |
09/17/2021 | PDSD Building Division - TEP PM Clearance | Passed | {Activity date: 09/17/2021; Status: Approved; Inspector: DMUNIZ; Comment: Entered by NGARCIA3 - CODE ECO} | |
09/17/2021 | COT - RSEL - Construction Power | Passed | {Activity date: 09/17/2021; Status: Approved; Inspector: DMUNIZ; Comment: Entered by NGARCIA3 - Approved Clear TEP ECO} | |
09/20/2021 | RSME - Mechanical Progress | Passed | {Activity date: 09/20/2021; Status: Approved; Inspector: DMUNIZ; Comment: Entered by VVERA1 - Approved } |
|
09/20/2021 | COT - RSPL - Gas Pressure Test | Passed | {Activity date: 09/20/2021; Status: Approved; Inspector: DMUNIZ; Comment: Entered by VVERA1 - Approved } |
|
09/22/2021 | COT - LCBU - Framing | Passed | {Activity date: 09/22/2021; Status: Approved; Inspector: DMUNIZ; Comment: Entered by RSALDAT1 - Approved} ; {Activity date: 09/20/2021; Status: Correction Required; Inspector: DMUNIZ; Comment: Entered by VVERA1 - corrections required, provide nail protection at top plate chase second floor for mechanical. Install HTT4 per plan, and install bolts at shear walls. Install hangers under staircase platform. } |
|
09/22/2021 | COT - LCPL - Plumbing Intermediate | Passed | {Activity date: 09/22/2021; Status: Approved; Inspector: DMUNIZ; Comment: Entered by RSALDAT1 - Approved} ; {Activity date: 09/20/2021; Status: Correction Required; Inspector: DMUNIZ; Comment: Entered by VVERA1 - corrections required, DWV test low, check for leaks and recall.} | |
10/01/2021 | COT - HCBU - Interior Shear Bracing | Passed | {Activity date: 10/01/2021; Status: Approved; Inspector: TGAUSP; Comment: Entered by NGARCIA3 - Approved} | |
12/10/2021 | COT - BULD - SWG Clearance | Passed | {Activity date: 12/10/2021; Status: Approved; Inspector: DMUNIZ; Comment: Entered by RSALDAT1 - CODE} | |
12/22/2021 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | {Activity date: 12/22/2021; Status: Approved; Inspector: DMUNIZ; Comment: Entered by NGARCIA3 - Approved 1090} | |
12/22/2021 | COT - RSME - Mechanical Final | Passed | {Activity date: 12/22/2021; Status: Approved; Inspector: DMUNIZ; Comment: Entered by NGARCIA3 - Approved} | |
12/22/2021 | RSBU - Building Final | Passed | {Activity date: 12/22/2021; Status: Partial Approval; Inspector: DMUNIZ; Comment: Entered by NGARCIA3 - APPROVED BY INSPECTOR AWAITING CONDITIONS} ; {Activity date: 12/22/2021; Status: Approved; Inspector: DMUNIZ; Comment: Entered by NGARCIA3 - Approved} | |
12/22/2021 | COT - RSEL - Outdoor Lighting | Passed | {Activity date: 12/22/2021; Status: Approved; Inspector: DMUNIZ; Comment: Entered by NGARCIA3 - Approved 2090} | |
12/22/2021 | COT - RSPL - Plumbing Final | Passed | {Activity date: 12/22/2021; Status: Approved; Inspector: DMUNIZ; Comment: Entered by NGARCIA3 - Approved} ; {Activity date: 12/10/2021; Status: Partial Approval; Inspector: DMUNIZ; Comment: Entered by RSALDAT1 - Partial clear southwest gas} | |
12/22/2021 | COT - RSEL - Electrical Final | Passed | {Activity date: 12/22/2021; Status: Approved; Inspector: DMUNIZ; Comment: Entered by NGARCIA3 - Approved} |