Permit: T21CM01752
Permit Details
Status:
Expired
Type:
Residential Building - One or Two Family
Address:
2655 N WARREN AV
Address NEW:
2655 N WARREN AV
Apply Date:
03/01/2021
Applicant:
Description:
Upgrade electrical panel to bring into compliance with new guidelines
Outstanding Inspections
Permit Status: Expired
Permit Number: T21CM01752
Permite Description: Upgrade electrical panel to bring into compliance with new guidelines
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/07/2022 | COT - RSEL - Electrical Final | N/A | Canceled | Inspection Canceled |
Completed Inspections
Permit Status: Expired
Permit Number: T21CM01752
Permit Description: Upgrade electrical panel to bring into compliance with new guidelines
Total Completed Inspections - 2
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/13/2021 | PDSD Building Division - TEP PM Clearance | Passed | {Activity date: 04/13/2021; Status: Approved; Inspector: RELEFANTE; Comment: Entered by VLEON1 - CODE INCR} | |
| 04/13/2021 | COT - RSEL - Service Upgrade | Passed | {Activity date: 04/13/2021; Status: Approved; Inspector: RELEFANTE; Comment: Entered by VLEON1 - } ; {Activity date: 04/09/2021; Status: Not ready for Inspection; Inspector: DQUINN; Comment: Entered by RSALDAT1 - nr Need : weatherhead, main feed lines, 2 mast brackets under the roof line, address label, install circuit wires to breakers, 2 ground rods 8’ deep and 6’ apart, along with gas and water bonds.} ; {Activity date: 03/12/2021; Status: Not ready for Inspection; Inspector: DQUINN; Comment: Entered by VLEON1 - } |