Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T20RW06252
Permit Details
Apply Date:
11/19/2020
Applicant:
CROWN CASTLE
Description:
BORE 1572' AND TRENCH 82' TO PLACE INNERDUCT AND CONDUIT. PLACE 6-30x48 VAULTS, PLACE AERIAL CABLE AND STRAND FOR 5681' NOTE: VERY EXTENSIVE PROJECT IN THE UNIVERSITY AREA; PEDESTRIAN SAFETY AND ACCESS IS OF UPMOST IMPORTANCE. INGRESS/ EGRESS FOR BUSINESS AND RESIDENTIAL ACCESS SHALL BE MAINTAINED. FIELD ADJUSTMENTS MAY BE REQUIRED. ALL AERIAL WORK MUST BE A MINIMUM OF 16-FT HIGH. PAVEMENT PATCHING IS NECESSARY WHERE PAVEMENT IS CUT. PATCH LIMITS- THE LIMITS OF THE PAVING SHALL BE A MINIMUM OF 1-FT OUTSIDE THE EXCAVATION. POTHOLES SPACED CLOSELY TOGETHER AND WITHIN 8-FT OF EACH OTHER WILL NEED TO BE JOINED TOGETHER BY ONE SURFACE PATCH. BACKFILL WITH CLSM SLURRY OR AGGREGATE BASE COURSE (ABC.) ASPHALTIC CONCRETE USED SHALL BE CITY OF TUCSON MIX NO. 3 OR COT MIX NO. 2 WITH TR-22, INSPECTOR TO ADVISE. REPAIR ALL LANDSCAPING DISTURBED. THIS INCLUDES IRRIGATION, PLANTINGS, GROUNDCOVER, AND HARDSCAPE. GOOD HOUSEKEEPING MEASURES SHALL BE PRACTICED DURING WORK AND CONSTRUCTION. MAINTAIN PEDESTRIAN ACCESS
Contractors:
- GW COMMUNICATION SOLUTIONS LLC
- R DIRECTIONAL DRILLING AND UNDERGROUND TECHNOLOG