Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T20RW04592
Permit Details
Apply Date:
08/12/2020
Applicant:
TERRACON
Description:
ll perform a vertical boring to an approximate depth of 40 feet below existing grade. The bore hole will be approximately 7 inches in diameter. The location of the boring will be approximately 15 feet north of the the north curb adjacent to South Research Loop (see site plan for details). Our work will take approximately 2 hours to complete.
Contractors:
- SOUTHLANDS ENGINEERING LLC
Completed Inspections
Permit Status: Final
Permit Number: T20RW04592
Permit Description: ll perform a vertical boring to an approximate depth of 40 feet below existing grade. The bore hole will be approximately 7 inches in diameter. The location of the boring will be approximately 15 feet north of the the north curb adjacent to South Research Loop (see site plan for details). Our work will take approximately 2 hours to complete.
Total Completed Inspections - 1
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/02/2020 | TDOT-EXCAV GENERAL INSPECTION | AGomez | Approved | Bore work was completed behind sidewalk, work area clean, no issues. |