Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Final
Type:
Barricade and Excavation
Address NEW:
2537 N FONTANA AV
Apply Date:
07/17/2020
Applicant:
CROWN CASTLE
Description:
BORE 94' AND TRENCH 8' TO PLACE INNERDUCT AND CONDUIT. PLACE AERIAL CABLE AND STRAND FOR 645'. PLACE 1 DOWN GUY AND ANCHOR AND PLACE 2-30X48 VAULTS FOR TUC46_014. INGRESS/ EGRESS FOR BUSINESS AND RESIDENTIAL ACCESS SHALL BE MAINTAINED. FIELD ADJUSTMENTS MAY BE REQUIRED. ALL AERIAL WORK MUST BE A MINIMUM OF 16-FT HIGH. PAVEMENT PATCHING IS NECESSARY WHERE PAVEMENT IS CUT. PATCH LIMITS- THE LIMITS OF THE PAVING SHALL BE A MINIMUM OF 1-FT OUTSIDE THE EXCAVATION. POTHOLES SPACED CLOSELY TOGETHER AND WITHIN 8-FT OF EACH OTHER WILL NEED TO BE JOINED TOGETHER BY ONE SURFACE PATCH. BACKFILL WITH CLSM SLURRY OR AGGREGATE BASE COURSE (ABC.) ASPHALTIC CONCRETE USED SHALL BE CITY OF TUCSON MIX NO. 3 OR COT MIX NO. 2 WITH TR-22, INSPECTOR TO ADVISE. REPAIR ALL LANDSCAPING DISTURBED. THIS INCLUDES IRRIGATION, PLANTINGS, GROUNDCOVER, AND HARDSCAPE. GOOD HOUSEKEEPING MEASURES SHALL BE PRACTICED DURING WORK AND CONSTRUCTION. MAINTAIN PEDESTRIAN ACCESS.
Contractors:
  • QUANTA TELECOMMUNICATION SERVICES. LLC
  • R DIRECTIONAL DRILLING AND UNDERGROUND TECHNOLOG

Outstanding Inspections

Permit Status: Final
Permit Number: T20RW04143
Permite Description: BORE 94' AND TRENCH 8' TO PLACE INNERDUCT AND CONDUIT. PLACE AERIAL CABLE AND STRAND FOR 645'. PLACE 1 DOWN GUY AND ANCHOR AND PLACE 2-30X48 VAULTS FOR TUC46_014. INGRESS/ EGRESS FOR BUSINESS AND RESIDENTIAL ACCESS SHALL BE MAINTAINED. FIELD ADJUSTMENTS MAY BE REQUIRED. ALL AERIAL WORK MUST BE A MINIMUM OF 16-FT HIGH. PAVEMENT PATCHING IS NECESSARY WHERE PAVEMENT IS CUT. PATCH LIMITS- THE LIMITS OF THE PAVING SHALL BE A MINIMUM OF 1-FT OUTSIDE THE EXCAVATION. POTHOLES SPACED CLOSELY TOGETHER AND WITHIN 8-FT OF EACH OTHER WILL NEED TO BE JOINED TOGETHER BY ONE SURFACE PATCH. BACKFILL WITH CLSM SLURRY OR AGGREGATE BASE COURSE (ABC.) ASPHALTIC CONCRETE USED SHALL BE CITY OF TUCSON MIX NO. 3 OR COT MIX NO. 2 WITH TR-22, INSPECTOR TO ADVISE. REPAIR ALL LANDSCAPING DISTURBED. THIS INCLUDES IRRIGATION, PLANTINGS, GROUNDCOVER, AND HARDSCAPE. GOOD HOUSEKEEPING MEASURES SHALL BE PRACTICED DURING WORK AND CONSTRUCTION. MAINTAIN PEDESTRIAN ACCESS.
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
09/29/2020 TDOT-EXCAV GENERAL INSPECTION N/A Continued Continued - R Directional on site performing conduit tie ins.

Documents

File Name Document Type  
T20RW04143 R1.PDF ROW-RIGHT OF WAY VIEW
T20RW04143.PDF ROW-RIGHT OF WAY VIEW