Description:
FIBER INSTALLATION FOR A&T SMALL WIRELESS CELL TUC30_066 VIA NEW AERIAL STRAND @ 1,413 LF. ALL AERIAL WORK MUST BE A MINIMUM OF 16-FT HIGH. MAINTAIN PEDESTRIAN ACCESS ALONG AERIAL ROUTE. MAINTAIN ACCESS TO BUS STOPS AND FOR PEDESTRIAN INGRESS/ EGRESS. BUS STOP IN THE AREA, CONTACT SUN TRAN, BEA PAULUS AT 520-206-8826 AND/OR CHRISTINA ROCK AT 520-206-8934 24-HOURS PRIOR TO START OF WORK FOR COORDINATION. OTHER ACTIVITIES IN THE AREA, WILL NEED TO COORDINATE TRAFFIC CONTROL SETUP WITH EXISTING SETUP. ADDRESS ON APPLICATION: 6220 S EARP WASH LN 06/24/2020 - PLAN REVISION PAVEMENT PATCHING IS NECESSARY WHERE PAVEMENT IS CUT. PATCH LIMITS- THE LIMITS OF THE PAVING SHALL BE A MINIMUM OF 1-FT OUTSIDE THE EXCAVATION. POTHOLES SPACED CLOSELY TOGETHER AND WITHIN 8-FT OF EACH OTHER WILL NEED TO BE JOINED TOGETHER BY ONE SURFACE PATCH. MORATORIUM REQUIREMENTS WILL BE CONVEYED IN THE FIELD BY THE INSPECTOR. BACKFILL WITH CLSM SLURRY OR AGGREGATE BASE COURSE (ABC.) ASPHALTIC CONCRETE USED SHALL BE CITY OF TUCSON MIX NO. 3 OR COT MIX NO. 2 WITH TR-22, INSPECTOR TO ADVISE. MAINTAIN PEDESTRIAN ACCESS
Contractors:
- R DIRECTIONAL DRILLING AND UNDERGROUND TECHNOLOG
Outstanding Inspections
Permit Status: Final
Permit Number: T20RW02124
Permite Description: FIBER INSTALLATION FOR A&T SMALL WIRELESS CELL TUC30_066 VIA NEW AERIAL STRAND @ 1,413 LF.
ALL AERIAL WORK MUST BE A MINIMUM OF 16-FT HIGH.
MAINTAIN PEDESTRIAN ACCESS ALONG AERIAL ROUTE.
MAINTAIN ACCESS TO BUS STOPS AND FOR PEDESTRIAN INGRESS/ EGRESS.
BUS STOP IN THE AREA, CONTACT SUN TRAN, BEA PAULUS AT 520-206-8826 AND/OR CHRISTINA ROCK AT 520-206-8934 24-HOURS PRIOR TO START OF WORK FOR COORDINATION.
OTHER ACTIVITIES IN THE AREA, WILL NEED TO COORDINATE TRAFFIC CONTROL SETUP WITH EXISTING SETUP.
ADDRESS ON APPLICATION: 6220 S EARP WASH LN
06/24/2020 - PLAN REVISION
PAVEMENT PATCHING IS NECESSARY WHERE PAVEMENT IS CUT.
PATCH LIMITS- THE LIMITS OF THE PAVING SHALL BE A MINIMUM OF 1-FT OUTSIDE THE EXCAVATION.
POTHOLES SPACED CLOSELY TOGETHER AND WITHIN 8-FT OF EACH OTHER WILL NEED TO BE JOINED TOGETHER BY ONE SURFACE PATCH.
MORATORIUM REQUIREMENTS WILL BE CONVEYED IN THE FIELD BY THE INSPECTOR.
BACKFILL WITH CLSM SLURRY OR AGGREGATE BASE COURSE (ABC.)
ASPHALTIC CONCRETE USED SHALL BE CITY OF TUCSON MIX NO. 3 OR COT MIX NO. 2 WITH TR-22, INSPECTOR TO ADVISE.
MAINTAIN PEDESTRIAN ACCESS
Total Outstanding Inspections - 1
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/25/2020 | TDOT-EXCAV GENERAL INSPECTION | N/A | Continued | PRECON SCRIPT WAS GONE OVER |