Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Final
Type:
Barricade Only
Address NEW:
10071 E SPEEDWAY BL
Apply Date:
01/21/2020
Applicant:
N/A
Description:
B&F Contracting Inc. will be Installing approximately 275 LF of 8'' CIPP Lining between MH# 8447-05 and 8447-04 Bypass pumps and pipe will be used on this site and will be set on the shoulder of the road. Traffic control will consist of a right lane closure for east bound Speedway Blvd at Firewood a flagger will be stationed at firewood to assist residents as needed. ADDRESS ON APPLICATION IS 10020 E. SPEEDWAY BL.
Contractors:
  • BORDER TRAFFIC SAFETY LLC
  • OLSEN PRECAST STRUCTURES
  • PROFESSIONAL PIPE SERVICES

Completed Inspections

Permit Status: Final
Permit Number: T20RW00335
Permit Description: B&F Contracting Inc. will be Installing approximately 275 LF of 8'' CIPP Lining between MH# 8447-05 and 8447-04 Bypass pumps and pipe will be used on this site and will be set on the shoulder of the road. Traffic control will consist of a right lane closure for east bound Speedway Blvd at Firewood a flagger will be stationed at firewood to assist residents as needed. ADDRESS ON APPLICATION IS 10020 E. SPEEDWAY BL.
Total Completed Inspections - 1
Date Description Inspector Results Comments
03/25/2020 TDOT-EXCAV GENERAL INSPECTION MVV Approved Appears completed. 2 new manhole concrete collars. Closed.

Documents

File Name Document Type  
T20RW00335.PDF ROW-RIGHT OF WAY VIEW
T20RW00335 R1.PDF ROW-RIGHT OF WAY VIEW