Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
Residential Building - One or Two Family
Apply Date:
09/10/2020
Applicant:
Description:
SFR F50B19 T19-M0033

Permit Reviews

Permit Number - T20CM06204
Permit Status: Expired
Permit Description: SFR F50B19 T19-M0033
Start Date Submittal Complete Date Status  
09/04/2020 RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO 10/06/2020 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T20CM06204
Permit Status: Expired
Permit Description: SFR F50B19 T19-M0033
Total Outstanding Activity Conditions - 4
Date Name
09/10/2020 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.
10/06/2020 SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED.
10/06/2020 SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED.
10/06/2020 SPECIAL INSPECTION FOR EXPANSION ANCHORS IS REQUIRED.

Outstanding Inspections

Permit Status: Expired
Permit Number: T20CM06204
Permite Description: SFR F50B19 T19-M0033
Total Outstanding Inspections - 2
Last Inspection Date Description Inspector Results Comments
11/04/2022 COT - RSBU - Exterior Clips/Sheathing N/A Canceled Inspection Canceled
11/07/2022 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. N/A Canceled Inspection Canceled

Completed Inspections

Permit Status: Expired
Permit Number: T20CM06204
Permit Description: SFR F50B19 T19-M0033
Total Completed Inspections - 19
Date Description Inspector Results Comments
11/25/2020 COT - RSPL - Yard Water Line Passed {Activity date: 11/25/2020; Status: Approved; Inspector: WGALLAGHER; Comment: Entered by RSALDAT1 - Approved}
11/25/2020 COT - RSPL - Sewer Passed {Activity date: 11/25/2020; Status: Approved; Inspector: WGALLAGHER; Comment: Entered by RSALDAT1 - Approved}
11/25/2020 COT - RSPL - Rough Soil Passed {Activity date: 11/25/2020; Status: Approved; Inspector: WGALLAGHER; Comment: Entered by RSALDAT1 - Approved}
12/07/2020 COT - RSEL - Grounding/Bonding Passed {Activity date: 12/07/2020; Status: Approved; Inspector: TTREMBULAK; Comment: Entered by PAHUMAD1 - } ; {Activity date: 12/04/2020; Status: Cancelled; Inspector: TTREMBULAK; Comment: Entered by PAHUMAD1 - All cancelled by contractor. Will reschedule when ready}
12/07/2020 COT - RSBU - Preslab Passed {Activity date: 12/07/2020; Status: Approved; Inspector: TTREMBULAK; Comment: Entered by PAHUMAD1 - } ; {Activity date: 12/04/2020; Status: Cancelled; Inspector: TTREMBULAK; Comment: Entered by PAHUMAD1 - All cancelled by contractor. Will reschedule when ready}
12/07/2020 COT - RSEL - Electrical Underground Passed {Activity date: 12/07/2020; Status: Approved; Inspector: TTREMBULAK; Comment: Entered by PAHUMAD1 - } ; {Activity date: 12/04/2020; Status: Cancelled; Inspector: TTREMBULAK; Comment: Entered by PAHUMAD1 - All cancelled by contractor. Will reschedule when ready}
12/07/2020 COT - RSBU - Excavation/Rebar/Zoning Passed {Activity date: 12/07/2020; Status: Approved; Inspector: TTREMBULAK; Comment: Entered by PAHUMAD1 - } ; {Activity date: 12/04/2020; Status: Cancelled; Inspector: TTREMBULAK; Comment: Entered by PAHUMAD1 - All cancelled by contractor. Will reschedule when ready}
01/15/2021 COT - RSBU - Roof Nailing Passed {Activity date: 01/15/2021; Status: Approved; Inspector: WGALLAGHER; Comment: Entered by VLEON1 - APPROVED}
02/12/2021 PDSD Building Division - TEP PM Clearance Passed {Activity date: 02/12/2021; Status: Approved; Inspector: RCHANDLER; Comment: Entered by VLEON1 - CODE TMPP}
02/12/2021 COT - RSEL - Construction Power Passed {Activity date: 02/12/2021; Status: Approved; Inspector: RCHANDLER; Comment: Entered by VLEON1 - APPROVED}
03/12/2021 COT - LCBU - Framing Passed {Activity date: 03/12/2021; Status: Approved; Inspector: WGALLAGHER; Comment: Entered by VLEON1 - }
03/12/2021 RSME - Mechanical Progress Passed {Activity date: 03/12/2021; Status: Approved; Inspector: WGALLAGHER; Comment: Entered by VLEON1 - }
03/12/2021 COT - RSPL - Gas Pressure Test Passed {Activity date: 03/12/2021; Status: Approved; Inspector: WGALLAGHER; Comment: Entered by VLEON1 - }
05/20/2021 COT - RSEL - Outdoor Lighting Passed {Activity date: 05/20/2021; Status: Approved; Inspector: RCHANDLER; Comment: Entered by RSALDAT1 - 2099 Outdoor Lighting Final-AP. SWG clearance.

} ; {Activity date: 01/15/2021; Status: Approved; Inspector: WGALLAGHER; Comment: Entered by VLEON1 - APPROVED}
05/20/2021 COT - BULD - SWG Clearance Passed {Activity date: 05/20/2021; Status: Approved; Inspector: RCHANDLER; Comment: Entered by RSALDAT1 - CODE}
05/25/2021 RSBU - Building Final Passed {Activity date: 05/25/2021; Status: Approved; Inspector: RCHANDLER; Comment: Entered by VLEON1 - }
05/25/2021 COT - RSEL - Electrical Final Passed {Activity date: 05/25/2021; Status: Approved; Inspector: RCHANDLER; Comment: Entered by VLEON1 - }
05/28/2021 COT - RSME - Mechanical Final Passed {Activity date: 05/28/2021; Status: Approved; Inspector: RCHANDLER; Comment: Entered by VLEON1 - } ; {Activity date: 05/25/2021; Status: Denied; Inspector: RCHANDLER; Comment: Entered by VLEON1 - DENIED 1-EXHAUST FAN IN LAUNDRY ROOM IS NOT WORKING}
05/28/2021 COT - RSPL - Plumbing Final Passed {Activity date: 05/28/2021; Status: Approved; Inspector: RCHANDLER; Comment: Entered by VLEON1 - } ; {Activity date: 05/25/2021; Status: Denied; Inspector: RCHANDLER; Comment: Entered by VLEON1 - DENIED INSTALL KITCHEN FAUCET}

Documents

File Name Document Type  
PERMIT.PDF DOCUMENTS VIEW
APPLICATION.PDF DOCUMENTS VIEW
JOB CARD.PDF DOCUMENTS VIEW
SPECIAL INSPECTION CERTIFICATE.PDF DOCUMENTS VIEW
WASTEWATER.PDF DOCUMENTS VIEW
SITE PLAN.PDF CONSTRPLANS VIEW