Start Date | Submittal | Complete Date | Status |
---|---|---|---|
07/14/2020 | RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO | 09/29/2020 | COMPLETED |
10/20/2020 | RESUBMITTAL | 11/30/2020 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T20CM05318
Permit Status: Expired
Permit Description: INTERIOR REMODEL
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
08/17/2020 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T20CM05318
Permite Description: INTERIOR REMODEL
Total Outstanding Inspections - 4
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/04/2022 | COT - RSME - Mechanical Final | N/A | Canceled | Inspection Canceled |
11/04/2022 | RSBU - Building Final | N/A | Canceled | Inspection Canceled |
11/04/2022 | COT - RSPL - Plumbing Final | N/A | Canceled | Inspection Canceled |
11/07/2022 | COT - RSPL - Rough Soil | N/A | Canceled | Inspection Canceled |
Completed Inspections
Permit Status: Expired
Permit Number: T20CM05318
Permit Description: INTERIOR REMODEL
Total Completed Inspections - 10
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/26/2021 | COT - RSPL - Yard Water Line | Passed | {Activity date: 01/26/2021; Status: Approved; Inspector: DQUINN; Comment: Entered by VLEON1 - APPROVED} ; {Activity date: 01/25/2021; Status: Cancelled; Inspector: DQUINN; Comment: Entered by VLEON1 - CANCELLED BY CARLOS} | |
01/26/2021 | BULD - Electrical Clearance | Passed | {Activity date: 01/26/2021; Status: Approved; Inspector: DQUINN; Comment: Entered by VLEON1 - CODE INCR} | |
03/08/2021 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | {Activity date: 03/08/2021; Status: Approved; Inspector: JBURGE; Comment: Entered by VLEON1 - APPROVED} | |
03/08/2021 | COT - LCBU - Framing | Passed | {Activity date: 03/08/2021; Status: Approved; Inspector: JBURGE; Comment: Entered by VLEON1 - APPROVED OK TO INSULATE AND COVER WALLS AND CEILINGS} ; {Activity date: 01/26/2021; Status: Not ready for Inspection; Inspector: DQUINN; Comment: Entered by VLEON1 - NOT READY NEED ALL INTERMEDIATES INSTALLED} ; {Activity date: 01/25/2021; Status: Cancelled; Inspector: DQUINN; Comment: Entered by VLEON1 - CANCELLED BY CARLOS} | |
03/08/2021 | COT - LCPL - Plumbing Intermediate | Passed | {Activity date: 03/08/2021; Status: Approved; Inspector: JBURGE; Comment: Entered by VLEON1 - APPROVED} | |
03/08/2021 | COT - RSEL - Outdoor Lighting | Passed | {Activity date: 03/08/2021; Status: Approved; Inspector: JBURGE; Comment: Entered by VLEON1 - APPROVED} | |
03/08/2021 | RSME - Mechanical Progress | Passed | {Activity date: 03/08/2021; Status: Approved; Inspector: JBURGE; Comment: Entered by VLEON1 - APPROVED} ; {Activity date: 01/26/2021; Status: Partial Approval; Inspector: DQUINN; Comment: Entered by VLEON1 - PARTIAL HVAC DUCTWORK OK DRYER VENTS MUST BE SOLID DUCT ONLY, NO FLEXT EXCEPT FOR DRYER CONNECTION} | |
03/08/2021 | COT - RSEL - Electrical Final | Passed | {Activity date: 03/08/2021; Status: Approved; Inspector: JBURGE; Comment: Entered by VLEON1 - APPROVED OK TO ENERGIZE SERVICE} | |
04/02/2021 | PDSD Building Division - TEP PM Clearance | Passed | {Activity date: 04/02/2021; Status: Approved; Inspector: JBURGE; Comment: Entered by RSALDAT1 - CODE INCR} ; {Activity date: 03/08/2021; Status: Approved; Inspector: JBURGE; Comment: Entered by VLEON1 - CODE ECO} | |
04/02/2021 | COT - RSEL - Service Upgrade | Passed | {Activity date: 04/02/2021; Status: Approved; Inspector: JBURGE; Comment: Entered by RSALDAT1 - Approved. Service increase from 125 amps to 200 amp service. Clearance; Code: INCR} ; {Activity date: 01/26/2021; Status: Approved; Inspector: DQUINN; Comment: Entered by VLEON1 - APPROVED} ; {Activity date: 01/25/2021; Status: Cancelled; Inspector: DQUINN; Comment: Entered by VLEON1 - CANCELLED BY CARLOS} |