Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
Residential Building - One or Two Family
Apply Date:
08/04/2020
Applicant:
Sue Taylor
Description:
NEW SFR AFST176919 T19-M0008

Permit Reviews

Permit Number - T20CM05027
Permit Status: Expired
Permit Description: NEW SFR AFST176919 T19-M0008
Start Date Submittal Complete Date Status  
08/04/2020 RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO 09/14/2020 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T20CM05027
Permit Status: Expired
Permit Description: NEW SFR AFST176919 T19-M0008
Total Outstanding Activity Conditions - 1
Date Name
08/04/2020 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Conditions

Permit Number - T20CM05027
Permit Status: Expired
Permit Description: NEW SFR AFST176919 T19-M0008
Date Description Comments
08/04/2020 SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED.

Outstanding Inspections

Permit Status: Expired
Permit Number: T20CM05027
Permite Description: NEW SFR AFST176919 T19-M0008
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
11/07/2022 RSBU - Building Final N/A Canceled Inspection Canceled

Completed Inspections

Permit Status: Expired
Permit Number: T20CM05027
Permit Description: NEW SFR AFST176919 T19-M0008
Total Completed Inspections - 23
Date Description Inspector Results Comments
09/16/2020 COT - RSPL - Yard Water Line Passed {Activity date: 09/16/2020; Status: Approved; Inspector: TTREMBULAK; Comment: Entered by RSALDAT1 - Approved}
09/16/2020 COT - RSPL - Sewer Passed {Activity date: 09/16/2020; Status: Approved; Inspector: TTREMBULAK; Comment: Entered by RSALDAT1 - Approved}
09/16/2020 COT - RSPL - Rough Soil Passed {Activity date: 09/16/2020; Status: Approved; Inspector: TTREMBULAK; Comment: Entered by RSALDAT1 - Approved}
09/22/2020 COT - RSEL - Grounding/Bonding Passed {Activity date: 09/22/2020; Status: Approved; Inspector: WGALLAGHER; Comment: Entered by JSCHNEI2 - Approved}
09/22/2020 COT - RSBU - Preslab Passed {Activity date: 09/22/2020; Status: Approved; Inspector: WGALLAGHER; Comment: Entered by JSCHNEI2 - Approved}
09/22/2020 COT - RSEL - Electrical Underground Passed {Activity date: 09/22/2020; Status: Approved; Inspector: WGALLAGHER; Comment: Entered by JSCHNEI2 - Approved}
09/22/2020 COT - RSBU - Excavation/Rebar/Zoning Passed {Activity date: 09/22/2020; Status: Approved; Inspector: WGALLAGHER; Comment: Entered by JSCHNEI2 - Approved}
10/09/2020 COT - RSBU - Roof Nailing Passed {Activity date: 10/09/2020; Status: Approved; Inspector: WGALLAGHER; Comment: Entered by JSCHNEI2 - Approved}
10/09/2020 COT - RSBU - Exterior Clips/Sheathing Passed {Activity date: 10/09/2020; Status: Approved; Inspector: WGALLAGHER; Comment: Entered by JSCHNEI2 - Approved}
10/28/2020 PDSD Building Division - TEP PM Clearance Passed {Activity date: 10/28/2020; Status: Approved; Inspector: WGALLAGHER; Comment: Entered by PAHUMAD1 - CODE ECO}
10/28/2020 COT - RSEL - Construction Power Passed {Activity date: 10/28/2020; Status: Approved; Inspector: WGALLAGHER; Comment: Entered by PAHUMAD1 - Approved ok for clearance eco}
12/14/2020 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed {Activity date: 12/14/2020; Status: Approved; Inspector: TTREMBULAK; Comment: Entered by VLEON1 - APPROVED}
12/14/2020 COT - LCBU - Framing Passed {Activity date: 12/14/2020; Status: Approved; Inspector: TTREMBULAK; Comment: Entered by VLEON1 - APPROVED}
12/14/2020 COT - LCPL - Plumbing Intermediate Passed {Activity date: 12/14/2020; Status: Approved; Inspector: TTREMBULAK; Comment: Entered by VLEON1 - APPROVED}
12/14/2020 RSEL - Electrical Progress Passed {Activity date: 12/14/2020; Status: Approved; Inspector: TTREMBULAK; Comment: Entered by VLEON1 - APPROVED}
12/14/2020 RSME - Mechanical Progress Passed {Activity date: 12/14/2020; Status: Approved; Inspector: TTREMBULAK; Comment: Entered by VLEON1 - APPROVED}
12/14/2020 COT - RSPL - Gas Pressure Test Passed {Activity date: 12/14/2020; Status: Approved; Inspector: TTREMBULAK; Comment: Entered by VLEON1 - APPROVED}
01/19/2021 COT - HCBU - Interior Shear Bracing Passed {Activity date: 01/19/2021; Status: Approved; Inspector: RCHANDLER; Comment: Entered by VLEON1 - APPROVED}
03/25/2021 COT - RSME - Mechanical Final Passed {Activity date: 03/25/2021; Status: Approved; Inspector: WGALLAGHER; Comment: Entered by VLEON1 - }
03/25/2021 COT - RSEL - Outdoor Lighting Passed {Activity date: 03/25/2021; Status: Approved; Inspector: WGALLAGHER; Comment: Entered by VLEON1 - }
03/25/2021 COT - RSPL - Plumbing Final Passed {Activity date: 03/25/2021; Status: Approved; Inspector: WGALLAGHER; Comment: Entered by VLEON1 - }
03/25/2021 COT - BULD - SWG Clearance Passed {Activity date: 03/25/2021; Status: Approved; Inspector: WGALLAGHER; Comment: Entered by VLEON1 - CODE} ; {Activity date: 12/14/2020; Status: Approved; Inspector: TTREMBULAK; Comment: Entered by VLEON1 - APPROVED}
03/25/2021 COT - RSEL - Electrical Final Passed {Activity date: 03/25/2021; Status: Approved; Inspector: WGALLAGHER; Comment: Entered by VLEON1 - }

Documents

File Name Document Type  
INSULATION CERT.PDF DOCUMENTS VIEW
PERMIT.PDF DOCUMENTS VIEW
APPLICATION.PDF DOCUMENTS VIEW
SPECIAL INSPECTION CERT..PDF DOCUMENTS VIEW
WASTEWATER.PDF DOCUMENTS VIEW
PLAN SET.PDF CONSTRPLANS VIEW