Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
Residential Building - One or Two Family
Address NEW:
5072 N WILD LIFE DR
Apply Date:
07/13/2020
Applicant:
JEFF STEWART
Description:
NEW SFR

Permit Reviews

Permit Number - T20CM04376
Permit Status: Expired
Permit Description: NEW SFR
Start Date Submittal Complete Date Status  
01/14/2021 REVISION - - 1ST 01/26/2021 COMPLETED Review Details
07/13/2020 RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO 08/14/2020 COMPLETED Review Details
09/11/2020 RESUBMITTAL 10/21/2020 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T20CM04376
Permit Status: Expired
Permit Description: NEW SFR
Total Outstanding Activity Conditions - 1
Date Name
07/14/2020 SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED.

Conditions

Permit Number - T20CM04376
Permit Status: Expired
Permit Description: NEW SFR
Date Description Comments
07/14/2020 ROOF TRUSSES MUST BE APPROVED PRIOR TO FRAMING INSPECTION (P2I)

Completed Inspections

Permit Status: Expired
Permit Number: T20CM04376
Permit Description: NEW SFR
Total Completed Inspections - 24
Date Description Inspector Results Comments
10/28/2020 COT - RSPL - Rough Soil Passed {Activity date: 10/28/2020; Status: Approved; Inspector: ESTEVENS; Comment: Entered by RSALDAT1 - Approved.}
10/29/2020 COT - RSPL - Yard Water Line Passed {Activity date: 10/29/2020; Status: Approved; Inspector: DQUINN; Comment: Entered by RSALDAT1 - Ap} ; {Activity date: 10/28/2020; Status: Not ready for Inspection; Inspector: ESTEVENS; Comment: Entered by RSALDAT1 - Not ready.}
11/16/2020 COT - RSEL - Grounding/Bonding Passed {Activity date: 11/16/2020; Status: Approved; Inspector: ESTEVENS; Comment: Entered by PAHUMAD1 - }
11/16/2020 COT - RSBU - Preslab Passed {Activity date: 11/16/2020; Status: Approved; Inspector: ESTEVENS; Comment: Entered by PAHUMAD1 - }
11/16/2020 COT - RSEL - Electrical Underground Passed {Activity date: 11/16/2020; Status: Approved; Inspector: ESTEVENS; Comment: Entered by PAHUMAD1 - }
11/16/2020 COT - RSBU - Excavation/Rebar/Zoning Passed {Activity date: 11/16/2020; Status: Approved; Inspector: ESTEVENS; Comment: Entered by PAHUMAD1 - } ; {Activity date: 10/28/2020; Status: Approved; Inspector: ESTEVENS; Comment: Entered by RSALDAT1 - Not ready.}
02/09/2021 COT - RSBU - Roof Nailing Passed {Activity date: 02/09/2021; Status: Approved; Inspector: DQUINN; Comment: Entered by VLEON1 - APPROVED}
02/09/2021 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed {Activity date: 02/09/2021; Status: Approved; Inspector: DQUINN; Comment: Entered by VLEON1 - APPROVED}
05/17/2021 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed {Activity date: 05/17/2021; Status: Approved; Inspector: TGAUSP; Comment: Entered by VLEON1 - APPROVED OK TO INSULATE AND DRYWALL}
05/17/2021 COT - LCPL - Plumbing Intermediate Passed {Activity date: 05/17/2021; Status: Approved; Inspector: TGAUSP; Comment: Entered by VLEON1 - }
05/17/2021 COT - BULD - SWG Clearance Passed {Activity date: 05/17/2021; Status: Approved; Inspector: TGAUSP; Comment: Entered by VLEON1 - CODE}
05/17/2021 RSME - Mechanical Progress Passed {Activity date: 05/17/2021; Status: Approved; Inspector: TGAUSP; Comment: Entered by VLEON1 - }
05/17/2021 COT - RSPL - Gas Pressure Test Passed {Activity date: 05/17/2021; Status: Approved; Inspector: TGAUSP; Comment: Entered by VLEON1 - }
06/01/2021 COT - HCBU - Interior Shear Bracing Passed {Activity date: 06/01/2021; Status: Approved; Inspector: DQUINN; Comment: Entered by RSALDAT1 - Ap}
06/15/2021 COT - LCBU - Framing Passed {Activity date: 06/15/2021; Status: Approved; Inspector: DQUINN; Comment: Entered by VLEON1 - } ; {Activity date: 02/09/2021; Status: Not ready for Inspection; Inspector: DQUINN; Comment: Entered by VLEON1 - NOT READY NEED INTERMEDIATES}
06/15/2021 PDSD Building Division - TEP PM Clearance Passed {Activity date: 06/15/2021; Status: Approved; Inspector: DQUINN; Comment: Entered by VLEON1 - CODE ECO}
06/15/2021 COT - RSEL - Construction Power Passed {Activity date: 06/15/2021; Status: Approved; Inspector: DQUINN; Comment: Entered by VLEON1 - }
10/13/2021 COT - RSME - Mechanical Final Passed {Activity date: 10/13/2021; Status: Approved; Inspector: DQUINN; Comment: Entered by NGARCIA3 - Ap 1090}
10/13/2021 RSBU - Building Final Passed {Activity date: 10/13/2021; Status: Approved; Inspector: DQUINN; Comment: Entered by NGARCIA3 - Ap}
10/13/2021 COT - RSEL - Outdoor Lighting Passed {Activity date: 10/13/2021; Status: Approved; Inspector: DQUINN; Comment: Entered by NGARCIA3 - Ap}
10/13/2021 COT - RSPL - Plumbing Final Passed {Activity date: 10/13/2021; Status: Approved; Inspector: DQUINN; Comment: Entered by NGARCIA3 - Ap 1090}
10/13/2021 COT - RSPL - Sewer Passed {Activity date: 10/13/2021; Status: Approved; Inspector: DQUINN; Comment: Entered by NGARCIA3 - Ap}
10/13/2021 COT - RSEL - Electrical Final Passed {Activity date: 10/13/2021; Status: Approved; Inspector: DQUINN; Comment: Entered by NGARCIA3 - Ap 1090}
10/14/2021 COT - FCON - Sprinkler - Final Passed {Activity date: 10/14/2021; Status: Approved; Inspector: jfordney; Comment: Entered by JFORDNE1 - approved by wmotto on 10/08/2021}

Documents

File Name Document Type  
JOB CARD.PDF DOCUMENTS VIEW
APPLICATION.PDF DOCUMENTS VIEW
REV1_TRUSSES.PDF DOCUMENTS VIEW
PERMIT.PDF DOCUMENTS VIEW
MANUAL J,S,D.PDF DOCUMENTS VIEW
PLAN SET.PDF CONSTRPLANS VIEW