Permit Details

Status:
L of c
Type:
COMMERCIAL ALTERATION
Apply Date:
04/30/2020
Applicant:
JOSE L CEJA
Description:
W - TI: OFFICE

Permit Reviews

Permit Number - T20CM02689
Permit Status: L of c
Permit Description: W - TI: OFFICE
Start Date Submittal Complete Date Status  
04/30/2020 COMMERCIAL - TI 06/12/2020 COMPLETED Review Details
08/10/2020 REVISION - - 1ST 08/26/2020 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T20CM02689
Permit Status: L of c
Permit Description: W - TI: OFFICE
Total Outstanding Activity Conditions - 1
Date Name
04/30/2020 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: L of c
Permit Number: T20CM02689
Permit Description: W - TI: OFFICE
Total Completed Inspections - 19
Date Description Inspector Results Comments
07/06/2020 ELECTRIC - INTERMEDIATE TTREMBULAK Approved Approved
07/06/2020 FRAMING TTREMBULAK Approved Partial. Electric in wall only.
07/09/2020 PLUMBING - ROUGH, SOIL TTREMBULAK Approved Approved
07/28/2020 MECHANICAL - INTERMEDIATE WGALLAGHER Approved Partial approval for ductwork and defusers need proper rated fuses in all indoor and outdoor units.
07/28/2020 PLUMBING - INTERMEDIATE WGALLAGHER Approved Partial approval above ceiling.
08/24/2020 ELECTRIC - ABOVE CEILING WGALLAGHER Approved Partial approval for 2nd floor only
09/08/2020 MECHANICAL - ABOVE CEILING DMUNIZ Approved Approved
10/01/2020 MECHANICAL - FINAL RSHERRY Approved REVIEW OF AIR BALANCE REPORT COMPLETE
11/02/2020 BUILDING ABOVE CEILING DMUNIZ Approved
11/02/2020 ELECTRIC - FINAL DMUNIZ Approved
11/02/2020 BUILDING ABOVE CEILING DMUNIZ Approved
11/02/2020 ENGINEERING - FINAL RDELONNE Approved Approved. No work outside of building per approved plans.
11/02/2020 ENGINEERING - FINAL RDELONNE Approved Approved. No work outside of building per approved plans.
11/04/2020 PLUMBING - FINAL RSHERRY Approved REVIEW OF WATER DISINFECTION REPORT COMPLETED
12/23/2020 BUILDING - FINAL TTREMBULAK Approved Cancelled by contractor. Will reschedule after fire inspections.
12/23/2020 FIRE - FINAL jfordney Approved per contractor
12/23/2020 FIRE - ALARM FINAL jfordney Approved per contractor
12/23/2020 FIRE SPKLR - FINAL jfordney Approved per contractor
06/22/2021 BUILDING - PROGRESS RELEFANTE Approved

Documents

File Name Document Type  
LOFC.PDF DOCUMENTS VIEW
PERMIT.PDF DOCUMENTS VIEW
GENERAL CONTRACTOR LETTR.PDF DOCUMENTS VIEW
REV1_1 20105 MECHCHECK.PDF DOCUMENTS VIEW
REV1_1 SYSTEMS DESIGN REPORT.PDF DOCUMENTS VIEW
REV1_1 PLAN SET C-3 MECHANICAL AND ELECTRICAL.PDF CONSTRPLANS VIEW
T20CM02689 WATER REPORT.PDF DOCUMENTS VIEW
1_APPLICATION.PDF DOCUMENTS VIEW
1_PLAN_SET.PDF CONSTRPLANS VIEW
1_SUBMITTAL CHECK LIST.PDF DOCUMENTS VIEW
PERMIT.PDF DOCUMENTS VIEW