Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Final
Type:
SINGLE FAMILY ALTERATION
Apply Date:
01/27/2020
Applicant:
KEVIN J DAVIS CONSTRUCTION LLC
Description:
INTERIOR REMODEL FOR SFR
Contractors:
  • KEVIN J DAVIS CONSTRUCTION LLC

Permit Reviews

Permit Number - T20CM00603
Permit Status: Final
Permit Description: INTERIOR REMODEL FOR SFR
Start Date Submittal Complete Date Status  
01/27/2020 RESIDENTIAL - BLDG/ZONING-WALKTHRU 01/27/2020 COMPLETED Review Details
02/11/2021 RESUBMITTAL 02/18/2021 COMPLETED Review Details
07/21/2020 REVISION - - 1ST 09/03/2020 COMPLETED Review Details
09/03/2020 REVISION - - 1ST 12/01/2020 COMPLETED Review Details
12/01/2020 REVISION - - 2ND 12/30/2020 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T20CM00603
Permit Status: Final
Permit Description: INTERIOR REMODEL FOR SFR
Total Outstanding Activity Conditions - 1
Date Name
01/27/2020 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T20CM00603
Permit Description: INTERIOR REMODEL FOR SFR
Total Completed Inspections - 11
Date Description Inspector Results Comments
04/28/2021 PLUMBING - PROGRESS JBURGE Approved
04/28/2021 PLUMBING - GAS PRESSURE TEST JBURGE Approved Approved. No clearance required at this time to set meter.
04/28/2021 ELECTRIC - SERVICE UPGRADE JBURGE Approved Approved. Service up graded to a 400 amp system. Under construction power. No clearance required at this time.
04/28/2021 RESIDENTIAL INTERMEDIATE JBURGE Approved Approved. Ok to insulate and cover walls.
12/09/2021 GAS CLEARANCE JBURGE Approved CODE
12/09/2021 BUILDING - FINAL JBURGE Approved Approved
12/09/2021 BUILDING - PROGRESS JBURGE Approved
12/09/2021 FRAMING JBURGE Approved 1080
12/09/2021 ELECTRIC - FINAL JBURGE Approved Approved
12/09/2021 PLUMBING - FINAL JBURGE Approved Approved
12/09/2021 MECHANICAL - FINAL JBURGE Approved Approved

CLEARANCE: Ok to reconnect gas meter. Called in to SW Gas at 1400 hours.

Please close out this permit.

Drop to add an attachment
Attachments

Documents

File Name Document Type  
ELECTRICAL PLAN.PDF DOCUMENTS VIEW
JOB CARD.PDF DOCUMENTS VIEW
MANUALS J,S,D SYSTEM_1.PDF DOCUMENTS VIEW
MANUALS J,S,D SYSTEM_2.PDF DOCUMENTS VIEW
MANUALS J,S,D SYSTEM_3.PDF DOCUMENTS VIEW
MECHANICAL PLAN.PDF DOCUMENTS VIEW
PERMIT.PDF DOCUMENTS VIEW
REVISED APPLICATION.PDF DOCUMENTS VIEW
PERMIT & JOB CARD.PDF DOCUMENTS VIEW
CHECKLIST.PDF DOCUMENTS VIEW
REV1_ENGINEER CALCULATIONS.PDF DOCUMENTS VIEW
REV1_PLAN SET (ZONING APPROVAL).PDF CONSTRPLANS VIEW
REV2_PLAN SET.PDF CONSTRPLANS VIEW
001_A1.TIF CONSTRPLANS VIEW
002_A2.TIF CONSTRPLANS VIEW
003_A3.TIF CONSTRPLANS VIEW
004_A4.TIF CONSTRPLANS VIEW
005_A5.TIF CONSTRPLANS VIEW
None DOCUMENTS VIEW