Permit: T20CM00159
Permit Details
Apply Date:
01/08/2020
Applicant:
David Shorey
Description:
E - INSTALL COMMERCIAL SOLAR SYSTEM
Permit Reviews
Permit Number - T20CM00159
Permit Status: Expired
Permit Description: E - INSTALL COMMERCIAL SOLAR SYSTEM
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 01/08/2020 | PLANS OK TO SUBMIT - COMM | 01/17/2020 | COMPLETED |
| 01/17/2020 | COMMERCIAL - BLDG/FIRE/ZONING/ENG | 02/10/2020 | COMPLETED |
| 02/10/2020 | RESUBMITTAL | 04/10/2020 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T20CM00159
Permit Status: Expired
Permit Description: E - INSTALL COMMERCIAL SOLAR SYSTEM
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 01/08/2020 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T20CM00159
Permite Description: E - INSTALL COMMERCIAL SOLAR SYSTEM
Total Outstanding Inspections - 4
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/04/2022 | COT - LCBU - Building Final | N/A | Canceled | Inspection Canceled |
| 11/04/2022 | COT - LCEL - Electrical Intermediate | N/A | Canceled | Inspection Canceled |
| 11/04/2022 | COT - LCEL - Electrical Final | N/A | Canceled | Inspection Canceled |
| 11/04/2022 | COT - LCEL - Service Upgrade | N/A | Canceled | Inspection Canceled |