Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Final
Type:
Barricade and Excavation
Address NEW:
1202 S BRISTOL AV
Apply Date:
03/18/2019
Applicant:
K E & G CONSTRUCTION ***APA***
Description:
Remove approximately 5 LF of 6" VCP and replace with 5 LF of 6" PVC at site one. Remove approximately 13 LF of 6" VCP and replace with 13 LF of 6" PVC at site two. Location of the two point repairs are between MH 9833-25 and MH 9833-26.
Contractors:
  • BORDER TRAFFIC SAFETY LLC
  • INSITUFORM TECHNOLOGIES LLC
  • PROPIPE PLUMBING AND ROOTER L L C

Completed Inspections

Permit Status: Final
Permit Number: T19RW01412
Permit Description: Remove approximately 5 LF of 6" VCP and replace with 5 LF of 6" PVC at site one. Remove approximately 13 LF of 6" VCP and replace with 13 LF of 6" PVC at site two. Location of the two point repairs are between MH 9833-25 and MH 9833-26.
Total Completed Inspections - 1
Date Description Inspector Results Comments
07/12/2019 TDOT-EXCAV GENERAL INSPECTION Bravin Approved Perm will need to be reissued when paving work starts.

Documents

File Name Document Type  
T19RW01412.PDF ROW-RIGHT OF WAY VIEW
T19RW1412 R1.PDF ROW-RIGHT OF WAY VIEW