Permit: T19PL00073
Permit Details
Status:
Final
Type:
SINGLE FAMILY OTHER
Address:
9223 E WOLFBERRY ST
Address NEW:
9223 E WOLFBERRY ST
Apply Date:
12/02/2019
Applicant:
STEWART SEAN
Description:
Upon having gas turned on after close of house. Southwest gas determined there was leak on existing gas piping. We removed the existing and installed up sized line to provide enough BTU for BBQ and fireplace. line will be installed on exterior of house with uni-strut clamps anchored in wall ever 8' for 1" and 3/4" lines and 6' for 1/2". black iron pipe ran underground is at 13" depth under concrete and pipe wrapped and primered to prevent corrosion.
Contractors:
- FUSION PLUMBING LLC
Outstanding Activity Conditions
Permit Number - T19PL00073
Permit Status: Final
Permit Description: Upon having gas turned on after close
of house. Southwest gas determined
there was leak on existing gas piping.
We removed the existing and installed
up sized line to provide enough BTU for
BBQ and fireplace. line will be installed
on exterior of house with uni-strut
clamps anchored in wall ever 8' for 1"
and 3/4" lines and 6' for 1/2". black iron
pipe ran underground is at 13" depth
under concrete and pipe wrapped and
primered to prevent corrosion.
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 12/02/2019 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T19PL00073
Permit Description: Upon having gas turned on after close
of house. Southwest gas determined
there was leak on existing gas piping.
We removed the existing and installed
up sized line to provide enough BTU for
BBQ and fireplace. line will be installed
on exterior of house with uni-strut
clamps anchored in wall ever 8' for 1"
and 3/4" lines and 6' for 1/2". black iron
pipe ran underground is at 13" depth
under concrete and pipe wrapped and
primered to prevent corrosion.
Total Completed Inspections - 4
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/05/2019 | GAS CLEARANCE | DMUNIZ | Approved | |
| 12/05/2019 | PLUMBING - GAS PRESSURE TEST | DMUNIZ | Approved | Verbal Clearance sent to Southwest Gas (RECN) |
| 12/05/2019 | PLUMBING - GAS RECONNECT | DMUNIZ | Approved | |
| 12/05/2019 | PLUMBING - FINAL | DMUNIZ | Approved |