Freestanding signage both sides of subdivision entry at Camino Boleadoras and Kolb (Just Needs La Estancia PAD approval letter to issue)
Permit Reviews
Permit Number - T19OT00101
Permit Status: Approved
Permit Description: Freestanding signage both sides of subdivision entry at Camino Boleadoras and Kolb (Just Needs La Estancia PAD approval letter to issue)
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
11/04/2022 | PERMANENT SIGN REVIEW v.1 | 12/08/2022 | APPROVED |
Completed Inspections
Permit Status: Approved
Permit Number: T19OT00101
Permit Description: Freestanding signage both sides of subdivision entry at Camino Boleadoras and Kolb (Just Needs La Estancia PAD approval letter to issue)
Total Completed Inspections - 1
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/19/2019 | COT - ENGR - Signage Final | Passed | {Activity date: 04/19/2019; Status: Approved; Inspector: Hthrall1; Comment: Entered by HTHRALL1 - Permit and inspection fees total $339.44} ; {Activity date: 04/15/2019; Status: Partial Approval; Inspector: Hthrall1; Comment: Entered by HTHRALL1 - RE: monument sign review For: La Estancia - NW corner of Camino Boleadoras / Kolb At: 7600 S Kolb Rd Permit: T19OT00101 Reviewer: H. Thrall Date: 4/15/19 (3rd submittal this sign) NOTE: staff in receipt of updated permit application emailed in 4/11 1) Separate electrical permit required to run power to the sign (acknowledged your note "power by others"). Ensure developer aware to begin that electrical permit process. 2) Check plat with any easements in the area and either show on plans if any/ or note none exist within sign location. Note that a blue stake will be done as well. 3) Provide developer's letter that the PAD development has accepted the proposed sign design. 4) FYI - Inspector Brian Wiese went to site to examine any grade slopes, none on parcel that would affect sign height as shown on plans from base grade at 6'1". (Max height of a monument sign is 10'). Elevation view of sign is acceptable. Please email updates to Heather.Thrall@tucsonaz.gov} ; {Activity date: 04/12/2019; Status: Continued; Inspector: Hthrall; Comment: Entered by HTHRALL1 - Received plan revision.} ; {Activity date: 04/04/2019; Status: Correction Required; Inspector: Hthrall; Comment: Entered by HTHRALL1 - RE: monument sign review For: La Estancia - NW corner of Camino Boleadoras / Kolb At: 7600 S Kolb Rd Permit: T19OT00101 Reviewer: H. Thrall Date: 4/4/19 (2nd submittal this sign) 1) Monument sign permitted at parcel per underlying commercial zoning of this PAD-7 phased development. Commercial development to be phase 3, per approved plats. 2) Separate electrical permit required to run power to the sign. Once issued, clarify where power source is from and where panel is for inspection and future access. B) note the volts, amps, circuits C) note the sign is UL listed (otherwise a separate inspection required to open the sign for electrical examination, fees would apply) 3) Outdoor Lighting Code, Ch. 4 & 5: A) provide notation: color temperature for internally illuminated sign shall not exceed 4400K 4) Enlarge site plan sheet to read notes and dimensions. A) Note dimensions of sight visibility triangle (acknowledged sign outside of it) B) Enlarge setback dimensions noted of each leading edge of sign to face of curb (20' minimum for monuments) to each adjacent street. C) Check plat with any easements in the area. (Staff emailing for assistance.) D) clarify if sign is within a common area of the subdivison 14109074B Owner: LANDMARK TITLE TR 18380-T Attn: Sunbelt Holdings OR... on parcel 141090630 Owner: LANDMARK TITLE TR 18380-T ATTN: SUNBELT HOLDINGS E) change spelling of roadway to Camino Boleadoras 5) Provide letter of land ownership and or property management with permission to proceed to install sign on this parcel. (Note -this sign may be in common area of the subdivision, acknowledged provided document set with a signature, uncertain who the signature belongs to in relationship with land developer/owner of Sunbelt Holdings, thank you.) 6) Please work with land developer to obtain written permission of PAD-7 zone La Estancia design review board to adopt sign design (may have already met to approve). Provide document. 7) Plan shows height at base of sign. Clarify height as installed from grade within a 5' difference around sign. Take the average of the 4 directions of grade at each side of the sign -and ensure sign height does not exceed 10' overall from that average point. Provide side diagram - check for slopes at site. 8) Revise sign permit application to update to address of 7600 S Kolb Road. (NW corner of Kolb and Camino Boleadoras) 9) Alert staff when sign location is marked for a setback/grade check. 10) further review comments may be forthcoming, depending upon responses provided. Note: other permit T19OT00315 is "sister permit" for the other sign on the SW corner of the same intersection (Camino Boleadoras and Kolb Road) Email revisions and or further data to Heather.Thrall@tucsonaz.gov} ; {Activity date: 03/06/2019; Status: Continued; Inspector: Hthrall; Comment: Entered by HTHRALL1 - RE: sign permit review - follow up for SDRC evaluation of master sign program For: La Estancia Planned Area Development (residential area phs 1, entry feature signs in commercial sub area of PAD in phs 3) zoned : PAD-7 Addressing - range, under 7600 S Kold Road Permit: T19OT00101 Reviewer: H. Thrall Date: 3/5/19 1) UPDATE - Research through La Estancia PAD-7 zoning document shows underlying commercial C-1 zoning base on the two lots and common area where the proposed detached signs are to be placed. These lots are reserved for commercial uses. Rather than use the Master Sign Program (MSP) per PAD District of the Sign Standards, because these lots are a base of commercial zoning as written in the PAD, the C-1 zone criteria can be used to install these signs, as proposed, at 30 approx square feet each, as monuments. PAD development permission required. The current phase under development/construction is residential low density - further west into the PAD site, off Kolb, along with roadway installation. As development as begun within the PAD, and phasing is accepted/planned/platted, these signs may be permitted/installed using the commercial zoning component, and a master sign program for other permanent signs (if proposed) can be pursued at another time, keeping same design criteria with materials as used in these signs. Emailed contractor and Sunbelt development with findings.} ; {Activity date: 02/08/2019; Status: Continued; Inspector: Hthrall; Comment: Entered by HTHRALL1 - RE: sign permit review For: La Estancia Planned Area Development (residential area) zoned : PAD-7 Addressing - range, under 7600 S Kold Road Permit: T19OT00101 Reviewer: H. Thrall 1) A master sign program will be required for the proposed design criteria of these signs, such as, but not limited to the sign area and number of signs requested for this residential development area. Contact Heather.Thrall@tucsonaz.gov for applications and process information. 2) Unclear where power coming from. Check for electrical source and clarify. Further review comments may be forthcoming.} |