Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
Residential Building - One or Two Family
Address NEW:
744 W CALLE PROGRESO
Apply Date:
12/30/2019
Applicant:
Description:
REPL WATER HEATER & GAS RECONNECT

Outstanding Activity Conditions

Permit Number - T19CM09467
Permit Status: Expired
Permit Description: REPL WATER HEATER & GAS RECONNECT
Total Outstanding Activity Conditions - 1
Date Name
12/30/2019 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Expired
Permit Number: T19CM09467
Permit Description: REPL WATER HEATER & GAS RECONNECT
Total Completed Inspections - 3
Date Description Inspector Results Comments
01/02/2020 COT - RSPL - Gas Pressure Test Passed {Activity date: 01/02/2020; Status: Approved; Inspector: DQUINN; Comment: Entered by DMERANZ1 - }
01/02/2020 COT - RSPL - Gas Reconnect Passed {Activity date: 01/02/2020; Status: Approved; Inspector: DQUINN; Comment: Entered by DMERANZ1 - }
01/03/2020 COT - RSPL - Plumbing Final Passed {Activity date: 01/03/2020; Status: Approved; Inspector: ESTEVENS; Comment: Entered by SFLORES2 - } ; {Activity date: 01/02/2020; Status: Not ready for Inspection; Inspector: DQUINN; Comment: Entered by DMERANZ1 - Need drip leg at h20 heater.
Need gas hard piped into cabinet, then flex from there on.
Need shut off valve at water feed line to h20 heater.}

Documents

File Name Document Type  