Permit: T19CM08620
Permit Details
Status:
Expired
Type:
Residential Building - One or Two Family
Address:
1125 S COYOTE SUMMIT PL
Address NEW:
1125 S COYOTE SUMMIT PL
Apply Date:
11/21/2019
Applicant:
Description:
NEW SFR MODEL - PLAN5071 T19-M0092
Permit Reviews
Permit Number - T19CM08620
Permit Status: Expired
Permit Description: NEW SFR MODEL - PLAN5071 T19-M0092
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 11/21/2019 | RESIDENTIAL - BLDG/ZONING-WALKTHRU | 11/21/2019 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T19CM08620
Permit Status: Expired
Permit Description: NEW SFR MODEL - PLAN5071 T19-M0092
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 11/21/2019 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Conditions
Permit Number - T19CM08620
Permit Status: Expired
Permit Description: NEW SFR MODEL - PLAN5071 T19-M0092
| Date | Description | Comments |
|---|---|---|
| 11/21/2019 | ROOF TRUSSES MUST BE APPROVED PRIOR TO FRAMING INSPECTION (P2I) | |
| 11/21/2019 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. |
Completed Inspections
Permit Status: Expired
Permit Number: T19CM08620
Permit Description: NEW SFR MODEL - PLAN5071 T19-M0092
Total Completed Inspections - 23
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/12/2019 | COT - RSPL - Yard Water Line | Passed | {Activity date: 12/12/2019; Status: Approved; Inspector: TVALENCIA; Comment: Entered by DMERANZ1 - } | |
| 12/12/2019 | COT - RSPL - Sewer | Passed | {Activity date: 12/12/2019; Status: Approved; Inspector: TVALENCIA; Comment: Entered by DMERANZ1 - } | |
| 12/13/2019 | COT - RSPL - Rough Soil | Passed | {Activity date: 12/13/2019; Status: Approved; Inspector: ESTEVENS; Comment: Entered by DMERANZ1 - } ; {Activity date: 12/12/2019; Status: Denied; Inspector: TVALENCIA; Comment: Entered by DMERANZ1 - 1- DWV water test was down. } |
|
| 12/27/2019 | COT - RSEL - Grounding/Bonding | Passed | {Activity date: 12/27/2019; Status: Approved; Inspector: ESTEVENS; Comment: Entered by DMERANZ1 - } | |
| 12/27/2019 | COT - RSBU - Preslab | Passed | {Activity date: 12/27/2019; Status: Approved; Inspector: ESTEVENS; Comment: Entered by DMERANZ1 - } | |
| 12/27/2019 | COT - RSEL - Electrical Underground | Passed | {Activity date: 12/27/2019; Status: Approved; Inspector: ESTEVENS; Comment: Entered by DMERANZ1 - } | |
| 12/27/2019 | COT - RSBU - Excavation/Rebar/Zoning | Passed | {Activity date: 12/27/2019; Status: Approved; Inspector: ESTEVENS; Comment: Entered by DMERANZ1 - } | |
| 01/27/2020 | COT - RSBU - Roof Nailing | Passed | {Activity date: 01/27/2020; Status: Approved; Inspector: TVALENCIA; Comment: Entered by DMERANZ1 - } | |
| 01/27/2020 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | {Activity date: 01/27/2020; Status: Approved; Inspector: TVALENCIA; Comment: Entered by DMERANZ1 - } | |
| 01/29/2020 | PDSD Building Division - TEP PM Clearance | Passed | {Activity date: 01/29/2020; Status: Approved; Inspector: ESTEVENS; Comment: Entered by DMERANZ1 - CODE ECO} | |
| 01/29/2020 | COT - RSEL - Construction Power | Passed | {Activity date: 01/29/2020; Status: Approved; Inspector: ESTEVENS; Comment: Entered by DMERANZ1 - The TEP clearance code is ECO.} | |
| 02/18/2020 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | {Activity date: 02/18/2020; Status: Approved; Inspector: TVALENCIA; Comment: Entered by DMERANZ1 - } | |
| 02/18/2020 | COT - LCBU - Framing | Passed | {Activity date: 02/18/2020; Status: Approved; Inspector: TVALENCIA; Comment: Entered by DMERANZ1 - } | |
| 02/18/2020 | COT - LCPL - Plumbing Intermediate | Passed | {Activity date: 02/18/2020; Status: Approved; Inspector: TVALENCIA; Comment: Entered by DMERANZ1 - } | |
| 02/18/2020 | RSME - Mechanical Progress | Passed | {Activity date: 02/18/2020; Status: Approved; Inspector: TVALENCIA; Comment: Entered by DMERANZ1 - } | |
| 02/18/2020 | COT - RSPL - Gas Pressure Test | Passed | {Activity date: 02/18/2020; Status: Approved; Inspector: TVALENCIA; Comment: Entered by DMERANZ1 - } | |
| 03/09/2020 | COT - HCBU - Interior Shear Bracing | Passed | {Activity date: 03/09/2020; Status: Approved; Inspector: DQUINN; Comment: Entered by DMERANZ1 - } | |
| 04/28/2020 | COT - RSPL - Plumbing Final | Passed | {Activity date: 04/28/2020; Status: Approved; Inspector: TVALENCIA; Comment: Entered by RSALDAT1 - Clear gas meter} | |
| 04/28/2020 | COT - BULD - SWG Clearance | Passed | {Activity date: 04/28/2020; Status: Approved; Inspector: TVALENCIA; Comment: Entered by RSALDAT1 - CODE} | |
| 05/18/2020 | COT - RSME - Mechanical Final | Passed | {Activity date: 05/18/2020; Status: Approved; Inspector: TVALENCIA; Comment: Entered by RSALDAT1 - } | |
| 05/18/2020 | COT - RSEL - Outdoor Lighting | Passed | {Activity date: 05/18/2020; Status: Approved; Inspector: TVALENCIA; Comment: Entered by RSALDAT1 - } | |
| 05/18/2020 | COT - RSEL - Electrical Final | Passed | {Activity date: 05/18/2020; Status: Approved; Inspector: TVALENCIA; Comment: Entered by RSALDAT1 - } | |
| 06/11/2020 | RSBU - Building Final | Passed | {Activity date: 06/11/2020; Status: Approved; Inspector: KEN; Comment: Entered by KKARSEN1 - CERT RECEIVED} ; {Activity date: 05/18/2020; Status: Partial Approval; Inspector: TVALENCIA; Comment: Entered by RSALDAT1 - INSPECTOR APPROVED BUILDING FINAL PENDING POST TENSION SPECIAL INSPECTION REPORTS. } |