Permit Status: Expired
Permit Description: SFR KBH128319 T19-M0062
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
11/12/2019 | RESIDENTIAL - BLDG/ZONING-WALKTHRU | 11/12/2019 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T19CM08357
Permit Status: Expired
Permit Description: SFR KBH128319 T19-M0062
Total Outstanding Activity Conditions - 3
Date | Name |
---|---|
11/12/2019 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
11/12/2019 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. |
11/12/2019 | SPECIAL INSPECTION FOR EXPANSION ANCHORS IS REQUIRED. |
Conditions
Permit Number - T19CM08357
Permit Status: Expired
Permit Description: SFR KBH128319 T19-M0062
Date | Description | Comments |
---|---|---|
11/15/2019 | ROOF TRUSSES MUST BE APPROVED PRIOR TO FRAMING INSPECTION (P2I) |
Completed Inspections
Permit Status: Expired
Permit Number: T19CM08357
Permit Description: SFR KBH128319 T19-M0062
Total Completed Inspections - 21
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/16/2019 | COT - RSPL - Yard Water Line | Passed | {Activity date: 12/16/2019; Status: Approved; Inspector: BSTEVENS; Comment: Entered by BSTEVENS - RVI} | |
12/16/2019 | COT - RSPL - Sewer | Passed | {Activity date: 12/16/2019; Status: Approved; Inspector: BSTEVENS; Comment: Entered by BSTEVENS - RVI} | |
12/16/2019 | COT - RSPL - Rough Soil | Passed | {Activity date: 12/16/2019; Status: Approved; Inspector: BSTEVENS; Comment: Entered by BSTEVENS - RVI} | |
12/23/2019 | COT - RSEL - Grounding/Bonding | Passed | {Activity date: 12/23/2019; Status: Approved; Inspector: BSTEVENS; Comment: Entered by BSTEVENS - RVI} | |
12/23/2019 | COT - RSBU - Preslab | Passed | {Activity date: 12/23/2019; Status: Approved; Inspector: BSTEVENS; Comment: Entered by BSTEVENS - RVI} | |
12/23/2019 | COT - RSBU - Excavation/Rebar/Zoning | Passed | {Activity date: 12/23/2019; Status: Approved; Inspector: BSTEVENS; Comment: Entered by BSTEVENS - RVI} | |
01/02/2020 | COT - RSBU - Exterior Clips/Sheathing | Passed | {Activity date: 01/02/2020; Status: Approved; Inspector: ESTEVENS; Comment: Entered by DMERANZ1 - } | |
01/06/2020 | COT - RSBU - Roof Nailing | Passed | {Activity date: 01/06/2020; Status: Approved; Inspector: WGALLAG1; Comment: Entered by DMERANZ1 - } ; {Activity date: 01/02/2020; Status: Denied; Inspector: ESTEVENS; Comment: Entered by DMERANZ1 - No ladder to access roof.} | |
01/13/2020 | PDSD Building Division - TEP PM Clearance | Passed | {Activity date: 01/13/2020; Status: Approved; Inspector: ESTEVENS; Comment: Entered by DMERANZ1 - CODE ECO} | |
01/13/2020 | COT - RSEL - Construction Power | Passed | {Activity date: 01/13/2020; Status: Approved; Inspector: ESTEVENS; Comment: Entered by DMERANZ1 - The TEP Clearance code is ECO.} | |
01/16/2020 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | {Activity date: 01/16/2020; Status: Approved; Inspector: RCHANDLER; Comment: Entered by DMERANZ1 - } | |
01/16/2020 | COT - LCBU - Framing | Passed | {Activity date: 01/16/2020; Status: Approved; Inspector: RCHANDLER; Comment: Entered by DMERANZ1 - } | |
01/16/2020 | COT - LCPL - Plumbing Intermediate | Passed | {Activity date: 01/16/2020; Status: Approved; Inspector: RCHANDLER; Comment: Entered by DMERANZ1 - } | |
01/16/2020 | RSME - Mechanical Progress | Passed | {Activity date: 01/16/2020; Status: Approved; Inspector: RCHANDLER; Comment: Entered by DMERANZ1 - } | |
01/29/2020 | COT - HCBU - Interior Shear Bracing | Passed | {Activity date: 01/29/2020; Status: Approved; Inspector: BSTEVENS; Comment: Entered by BSTEVENS - RVI} | |
03/06/2020 | COT - RSPL - Gas Pressure Test | Passed | {Activity date: 03/06/2020; Status: Approved; Inspector: BSTEVENS; Comment: Entered by BSTEVENS - } ; {Activity date: 01/16/2020; Status: Partial Approval; Inspector: RCHANDLER; Comment: Entered by DMERANZ1 - Test is holding, but left open to allow scheduling when ready to connect.} | |
03/31/2020 | COT - RSME - Mechanical Final | Passed | {Activity date: 03/31/2020; Status: Approved; Inspector: ESTEVENS; Comment: Entered by SFLORES2 - RVI} | |
03/31/2020 | RSBU - Building Final | Passed | {Activity date: 03/31/2020; Status: Approved; Inspector: ESTEVENS; Comment: Entered by SFLORES2 - RVI} | |
03/31/2020 | COT - RSEL - Outdoor Lighting | Passed | {Activity date: 03/31/2020; Status: Approved; Inspector: ESTEVENS; Comment: Entered by SFLORES2 - RVI} | |
03/31/2020 | COT - RSPL - Plumbing Final | Passed | {Activity date: 03/31/2020; Status: Approved; Inspector: ESTEVENS; Comment: Entered by SFLORES2 - RVI} | |
03/31/2020 | COT - RSEL - Electrical Final | Passed | {Activity date: 03/31/2020; Status: Approved; Inspector: ESTEVENS; Comment: Entered by SFLORES2 - } |