Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
Residential Building - One or Two Family
Address NEW:
2881 N FAIR OAKS AV
Apply Date:
10/03/2019
Applicant:
Description:
NEW SFR: CORN150019 T19-M0094

Permit Reviews

Permit Number - T19CM07240
Permit Status: Expired
Permit Description: NEW SFR: CORN150019 T19-M0094
Start Date Submittal Complete Date Status  
10/03/2019 RESIDENTIAL - BLDG/ZONING-WALKTHRU 10/03/2019 COMPLETED Review Details
10/22/2019 REVISION - - 1ST 10/22/2019 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T19CM07240
Permit Status: Expired
Permit Description: NEW SFR: CORN150019 T19-M0094
Total Outstanding Activity Conditions - 2
Date Name
10/03/2019 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.
10/03/2019 SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED.

Conditions

Permit Number - T19CM07240
Permit Status: Expired
Permit Description: NEW SFR: CORN150019 T19-M0094
Date Description Comments
10/03/2019 ROOF TRUSSES MUST BE APPROVED PRIOR TO FRAMING INSPECTION (P2I)

Outstanding Inspections

Permit Status: Expired
Permit Number: T19CM07240
Permite Description: NEW SFR: CORN150019 T19-M0094
Total Outstanding Inspections - 2
Last Inspection Date Description Inspector Results Comments
03/31/2020 COT - LCPL - Plumbing Roof Drains N/A Canceled {Activity date: 03/31/2020; Status: Not Applicable; Inspector: RCHANDLER; Comment: Entered by SFLORES2 - }
03/31/2020 RSPL - Plumbing Progress N/A Canceled {Activity date: 03/31/2020; Status: Not Applicable; Inspector: RCHANDLER; Comment: Entered by SFLORES2 - }

Completed Inspections

Permit Status: Expired
Permit Number: T19CM07240
Permit Description: NEW SFR: CORN150019 T19-M0094
Total Completed Inspections - 24
Date Description Inspector Results Comments
10/08/2019 COT - RSPL - Rough Soil Passed {Activity date: 10/08/2019; Status: Approved; Inspector: JCLAXTON; Comment: Entered by DMERANZ1 - }
10/17/2019 COT - RSBU - Excavation/Rebar/Zoning Passed {Activity date: 10/17/2019; Status: Approved; Inspector: RCHANDLER; Comment: Entered by DMERANZ1 - }
10/23/2019 COT - RSBU - Preslab Passed {Activity date: 10/23/2019; Status: Approved; Inspector: RCHANDLER; Comment: Entered by DMERANZ1 - Note: Fire wall added to South side. Fire wall added to resolve corrections.} ; {Activity date: 10/17/2019; Status: Correction Required; Inspector: RCHANDLER; Comment: Entered by DMERANZ1 - 1-Provide survey corner pins and string line between them for South property line to verify required 3’ Fire Separation Distance for unrated wall.
2-Install Ufer.}
11/18/2019 COT - RSBU - Roof Nailing Passed {Activity date: 11/18/2019; Status: Approved; Inspector: RCHANDLER; Comment: Entered by DMERANZ1 - }
11/27/2019 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed {Activity date: 11/27/2019; Status: Approved; Inspector: RCHANDLER; Comment: Entered by DMERANZ1 - Inspected via Face-Time. Per Builder and Inspection Supervisor openings can be recessed, and will be complete for inspection at intermediate.} ; {Activity date: 11/22/2019; Status: Correction Required; Inspector: RCHANDLER; Comment: Entered by DMERANZ1 - 1-1-Strap is not installed per approved plans.
2-No house on adjacent property; obtain verification from registered surveyor stating where foundation is in relation to South property line, to determine if openings need to be moved or eliminated.} ; {Activity date: 11/18/2019; Status: Correction Required; Inspector: RCHANDLER; Comment: Entered by DMERANZ1 - 1-Install strap at rake plate to flat top plate.
2-Obtain revision for fire-wall required on South side
}
01/07/2020 PDSD Building Division - TEP PM Clearance Passed {Activity date: 01/07/2020; Status: Approved; Inspector: RCHANDLER; Comment: Entered by DMERANZ1 - CODE ECO}
01/07/2020 COT - RSEL - Construction Power Passed {Activity date: 01/07/2020; Status: Approved; Inspector: RCHANDLER; Comment: Entered by DMERANZ1 - Clearance TEP eco.} ; {Activity date: 01/06/2020; Status: Correction Required; Inspector: RCHANDLER; Comment: Entered by DMERANZ1 - Connect Ufer to service}
01/10/2020 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed {Activity date: 01/10/2020; Status: Approved; Inspector: RCHANDLER; Comment: Entered by DMERANZ1 - }
01/10/2020 COT - LCBU - Framing Passed {Activity date: 01/10/2020; Status: Approved; Inspector: RCHANDLER; Comment: Entered by DMERANZ1 - } ; {Activity date: 11/22/2019; Status: Not ready for Inspection; Inspector: RCHANDLER; Comment: Entered by DMERANZ1 - Work incomplete. This should be scheduled when intermediate is ready.} ; {Activity date: 11/18/2019; Status: Correction Required; Inspector: RCHANDLER; Comment: Entered by DMERANZ1 - Obtain revision for fire-wall required on South side}
01/10/2020 COT - LCPL - Plumbing Intermediate Passed {Activity date: 01/10/2020; Status: Approved; Inspector: RCHANDLER; Comment: Entered by DMERANZ1 - }
01/10/2020 RSME - Mechanical Progress Passed {Activity date: 01/10/2020; Status: Approved; Inspector: RCHANDLER; Comment: Entered by DMERANZ1 - }
01/23/2020 COT - RSBU - Firewall/Fire Barrier/Firestop Passed {Activity date: 01/23/2020; Status: Approved; Inspector: RCHANDLER; Comment: Entered by DMERANZ1 - }
01/30/2020 COT - HCBU - Interior Shear Bracing Passed {Activity date: 01/30/2020; Status: Approved; Inspector: RCHANDLER; Comment: Entered by DMERANZ1 - }
03/31/2020 COT - RSEL - Grounding/Bonding Passed {Activity date: 03/31/2020; Status: Approved; Inspector: RCHANDLER; Comment: Entered by SFLORES2 - RVI}
03/31/2020 COT - RSME - Mechanical Final Passed {Activity date: 03/31/2020; Status: Approved; Inspector: RCHANDLER; Comment: Entered by SFLORES2 - } ; {Activity date: 03/27/2020; Status: Cancelled; Inspector: RCHANDLER; Comment: Entered by SFLORES2 - CA per phone call with customer.}
03/31/2020 RSBU - Building Final Passed {Activity date: 03/31/2020; Status: Approved; Inspector: RCHANDLER; Comment: Entered by SFLORES2 - RVI} ; {Activity date: 03/27/2020; Status: Cancelled; Inspector: RCHANDLER; Comment: Entered by SFLORES2 - CA per phone call with customer.}
03/31/2020 COT - RSPL - Yard Water Line Passed {Activity date: 03/31/2020; Status: Approved; Inspector: RCHANDLER; Comment: Entered by SFLORES2 - RVI}
03/31/2020 COT - RSEL - Outdoor Lighting Passed {Activity date: 03/31/2020; Status: Approved; Inspector: RCHANDLER; Comment: Entered by SFLORES2 - RVI}
03/31/2020 COT - RSEL - Electrical Underground Passed {Activity date: 03/31/2020; Status: Approved; Inspector: RCHANDLER; Comment: Entered by SFLORES2 - RVI}
03/31/2020 COT - RSPL - Plumbing Final Passed {Activity date: 03/31/2020; Status: Approved; Inspector: RCHANDLER; Comment: Entered by SFLORES2 - } ; {Activity date: 03/27/2020; Status: Cancelled; Inspector: RCHANDLER; Comment: Entered by SFLORES2 - CA per phone call with customer.}
03/31/2020 COT - RSPL - Sewer Passed {Activity date: 03/31/2020; Status: Approved; Inspector: RCHANDLER; Comment: Entered by SFLORES2 - per previous inspection records.}
03/31/2020 COT - BULD - SWG Clearance Passed {Activity date: 03/31/2020; Status: Approved; Inspector: RCHANDLER; Comment: Entered by SFLORES2 - }
03/31/2020 COT - RSPL - Gas Pressure Test Passed {Activity date: 03/31/2020; Status: Approved; Inspector: RCHANDLER; Comment: Entered by SFLORES2 - SWG

OK to connect.}
03/31/2020 COT - RSEL - Electrical Final Passed {Activity date: 03/31/2020; Status: Approved; Inspector: RCHANDLER; Comment: Entered by SFLORES2 - RVI} ; {Activity date: 03/27/2020; Status: Cancelled; Inspector: RCHANDLER; Comment: Entered by SFLORES2 - CA per phone call with customer.}

Documents

File Name Document Type  
None DOCUMENTS VIEW