Permit Details

Status:
C of o
Type:
COMMERCIAL ALTERATION
Address:
319 W SIMPSON ST
Apply Date:
08/01/2019
Applicant:
LANNING, ROBERT SCOTT
Description:
TI: OFFICE
Contractors:
  • SOUTHWEST URBAN BUILDERS LLC

Permit Reviews

Permit Number - T19CM05503
Permit Status: C of o
Permit Description: TI: OFFICE
Start Date Submittal Complete Date Status  
08/01/2019 COMMERCIAL - TI 08/09/2019 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T19CM05503
Permit Status: C of o
Permit Description: TI: OFFICE
Total Outstanding Activity Conditions - 1
Date Name
08/01/2019 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T19CM05503
Permit Description: TI: OFFICE
Total Completed Inspections - 27
Date Description Inspector Results Comments
08/01/2019 PLUMBING - FINAL RSHERRY Approved WATER DISINFECTION REPORT REQUIRED
08/07/2019 MECHANICAL - FINAL RSHERRY Approved AIR BALANCE REPORT REQUIRED
11/21/2019 U VALUE FOR WINDOW JBURGE Approved Windows meet Historical Society standards.
11/21/2019 ROOF NAILING JBURGE Approved
11/21/2019 PLUMBING - YARD WTR LINE/TEST JBURGE Approved
11/21/2019 PLUMBING - ROUGH, SOIL JBURGE Approved Ok to cover progress area.
12/04/2019 TEP CLEARANCE - PM ESTEVENS Approved CODE TMPP
12/04/2019 ELECTRIC - CONSTRUCTION POWER ESTEVENS Approved
01/21/2020 FRAMING TVALENCIA Approved
02/24/2020 MECHANICAL - INTERMEDIATE JBURGE Approved In wall mechanical is in place, thermostat lines in place.
02/24/2020 PLUMBING - INTERMEDIATE JBURGE Approved
02/24/2020 ELECTRIC - TEMPORARY SERVICE JBURGE Approved Temporary electric service is in place.
02/24/2020 ELECTRIC - UNDERGROUND JBURGE Approved
02/24/2020 ELECTRIC - UFER JBURGE Approved
02/24/2020 BUILDING ABOVE CEILING JBURGE Approved
03/03/2020 ELECTRIC - SERVICE UPGRADE ESTEVENS Approved The TEP clearance code is INCR.
03/03/2020 ELECTRIC - ABOVE CEILING ESTEVENS Approved
03/03/2020 ELECTRIC - INTERMEDIATE ESTEVENS Approved
03/19/2020 REINFORCED MASONRY PRE-GROUT JBURGE Approved
04/10/2020 PLUMBING - BACK WATER VALVE TVALENCIA Approved
04/10/2020 ELECTRIC - OUTDOOR LIGHTING TVALENCIA Approved
04/17/2020 ELECTRIC - FINAL TVALENCIA Approved
04/17/2020 OUTDOOR LIGHTING FINAL TVALENCIA Approved
04/17/2020 BUILDING - FINAL TVALENCIA Approved
04/17/2020 RESIDENTIAL INTERMEDIATE TVALENCIA Approved
05/12/2020 ENGINEERING - FINAL DROBERTS Approved THIS INSPECTION IS BEING APPROVED AT THIS TIME SINCE IT HAS BEEN ACCEPTED BY THE TRANSPORTATION DEPARTMENT. ALL PREVIOUSLY NOTED COMMENTS ARE ISSUES WITHIN THE RIGHTS OF WAY AND IS APPROVED WITH THE APPROVAL OF THE BUILDING OFFICIAL ON 5/12/2020.

BELOW IS THE LIST OF THE ORIGINAL COMMENTS MADE DURING MY INSPECTION OF THE SITE ON 4/17/2020:

IS PARTIALED AT THIS TIME DUE TO THE SITE WORK IS NOT COMPLETE. THE FOLLOWING ITEMS HAVE BEEN NOTED INCORRECT DURING THIS SITE VISIT:
1) THE ADA PARKING SPACE IS NOT IN THE LOCATION THAT IS SHOWN ON THE APPROVED PLANS AND IS NONCOMPLIANT. PROVIDE US WITH APPROVED REVISED DRAWINGS FOR THIS CHANGE, OR CONSTRUCT THIS AS IT HAS BEEN APPROVED. ALSO THE RUNNING SLOPE OF THE ROADWAY WHERE THE PARKING SPACE IS TO BE CONSTRUCTED IS BETWEEN 2.6% AND 4.0%, THIS NEEDS TO BE 2% OR LESS IN ALL DIRECTIONS WHEN IT IS INSPECTED.
2) THE SIDEWALK THAT IS SHOWN IN THE AREA BETWEEN THE APPROVED PARKING SPACE AND THE ACCESS TO THE BUILDING IS NON COMPLIANT FOR THE CROSS SLOPE. CURRENTLY THE SLOPES IN THIS AREA VARY BETWEEN 2.6% TO OVER 4%, THIS WILL NEED TO BE ADDRESSED FOR THE PARKING SPACE/ACCESS AISLE TO BE COMPLIANT. ALSO AT THE DOORWAY THERE IS NOT A LANDING AT THE TOP OF THE RAMP TO ALLOW FOR A POINT OF REST WHILE OPENING THE DOOR, THE LANDING IS ON THE INSIDE OF THE DOOR.
3) THE ISSUES NOTED IN THIS AREA ARE THE RESPONSIBILITY OF THE RIGHT OF WAY DEPARTMENT FOR THE CITY OF TUCSON TRANSPORTATION DEPT. THE ACCESS RAMP LOCATED AT THE SOUTHWEST CORNER OF THIS BUILDING IS NON-COMPLIANT IN THE FOLLOWING AREAS. IT IS MISSING THE KICK PLATE ON THE RIGHT SIDE OF THE HANDRAIL GOING UP THE RAMP AND THE HANDRAIL ON THE LEFT SIDE OF THE SAME RAMP GOING UP.
4) COMPLETE THE LANDSCAPING AROUND THIS SITE PRIOR TO RECALLING THIS INSPECTION AGAIN. ALL DISTURBED AREAS WILL NEED TO HAVE SOME TYPE OF LANDSCAPING MATERIAL APPLIED EITHER PLANTS, DECOMPSED GRANITE, OR HYDROSEED PRIOR TO APPROVAL OF THE SITE.
05/12/2020 ENGINEERING - FINAL DROBERTS Approved PARTIAL AT THIS TIME AS NOTED ON THE PREVIOUS INSPECTION FOR THIS SITE IN APRIL OF THIS YEAR. I AM WAITING ON A DECISION FROM C.O.T. TRANSPORTATION SINCE MY COMMENTS REFER TO WORK DONE IN THE RIGHTS OF WAY IN REGARDS TO THE NONCOMPLIANT ADA PARKING SPACE, ACCESS AISLE, AND PATHWAY INTO THE BUILDING FROM SIMPSON STREET.

Documents

File Name Document Type  
TEMPOARAY COFO REQUEST.PDF DOCUMENTS VIEW
TEMPOARAY COFO.PDF DOCUMENTS VIEW
COFO.PDF DOCUMENTS VIEW
001_A-0.TIF CONSTRPLANS VIEW
002_A-1.TIF CONSTRPLANS VIEW
003_A-2.TIF CONSTRPLANS VIEW
004_A-3.TIF CONSTRPLANS VIEW
005_A-4.TIF CONSTRPLANS VIEW
006_S-0.1.TIF CONSTRPLANS VIEW
007_S-1.1.TIF CONSTRPLANS VIEW
008_S-2.1.TIF CONSTRPLANS VIEW
009_S-3.1.TIF CONSTRPLANS VIEW
010_S-4.1.TIF CONSTRPLANS VIEW
011_M-1.TIF CONSTRPLANS VIEW
012_M-2.TIF CONSTRPLANS VIEW
013_M-3.TIF CONSTRPLANS VIEW
014_M-4.TIF CONSTRPLANS VIEW
015_P-1.TIF CONSTRPLANS VIEW
016_P-2.TIF CONSTRPLANS VIEW
017_P-3.TIF CONSTRPLANS VIEW
018_P-4.TIF CONSTRPLANS VIEW
019_P-5.TIF CONSTRPLANS VIEW
020_SPECS / LEGEND / LIGHT FIXURES.TIF CONSTRPLANS VIEW
021_PANELS / SINGLE LINE DIAGRAM.TIF CONSTRPLANS VIEW
022_POWER / OUTLET PLAN.TIF CONSTRPLANS VIEW
023_LIGHTING PLAN.TIF CONSTRPLANS VIEW
024_A-0.TIF CONSTRPLANS VIEW
None DOCUMENTS VIEW