Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
Residential Building - One or Two Family
Apply Date:
07/23/2019
Applicant:
Description:
SFR LEN400418 T18-M0080

Permit Reviews

Permit Number - T19CM05207
Permit Status: Expired
Permit Description: SFR LEN400418 T18-M0080
Start Date Submittal Complete Date Status  
07/23/2019 RESIDENTIAL - BLDG/ZONING-WALKTHRU 07/23/2019 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T19CM05207
Permit Status: Expired
Permit Description: SFR LEN400418 T18-M0080
Total Outstanding Activity Conditions - 1
Date Name
07/23/2019 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Conditions

Permit Number - T19CM05207
Permit Status: Expired
Permit Description: SFR LEN400418 T18-M0080
Date Description Comments
07/23/2019 ROOF TRUSSES MUST BE APPROVED PRIOR TO FRAMING INSPECTION (P2I)
07/23/2019 SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED.

Completed Inspections

Permit Status: Expired
Permit Number: T19CM05207
Permit Description: SFR LEN400418 T18-M0080
Total Completed Inspections - 23
Date Description Inspector Results Comments
08/16/2019 COT - RSPL - Yard Water Line Passed {Activity date: 08/16/2019; Status: Approved; Inspector: AKLEINSORGE; Comment: Entered by DMERANZ1 - Ok to backfill
}
08/16/2019 COT - RSPL - Sewer Passed {Activity date: 08/16/2019; Status: Approved; Inspector: AKLEINSORGE; Comment: Entered by DMERANZ1 - Ok to backfill
}
08/16/2019 COT - RSPL - Rough Soil Passed {Activity date: 08/16/2019; Status: Approved; Inspector: AKLEINSORGE; Comment: Entered by DMERANZ1 - Ok to backfill
}
08/21/2019 COT - RSEL - Grounding/Bonding Passed {Activity date: 08/21/2019; Status: Approved; Inspector: AKLEINSORGE; Comment: Entered by DMERANZ1 - }
08/21/2019 COT - RSBU - Preslab Passed {Activity date: 08/21/2019; Status: Approved; Inspector: AKLEINSORGE; Comment: Entered by DMERANZ1 - Ok for concrete placement
}
08/21/2019 COT - RSEL - Electrical Underground Passed {Activity date: 08/21/2019; Status: Approved; Inspector: AKLEINSORGE; Comment: Entered by DMERANZ1 - }
08/21/2019 COT - RSBU - Excavation/Rebar/Zoning Passed {Activity date: 08/21/2019; Status: Approved; Inspector: AKLEINSORGE; Comment: Entered by DMERANZ1 - Move #4 rebar in front bathroom so that it is around the plumbing box before concrete placement, currently around wrong pipe. Ok for concrete placement}
09/09/2019 COT - RSBU - Roof Nailing Passed {Activity date: 09/09/2019; Status: Approved; Inspector: DMUNIZ; Comment: Entered by DMERANZ1 - }
09/09/2019 COT - RSBU - Exterior Clips/Sheathing Passed {Activity date: 09/09/2019; Status: Approved; Inspector: DMUNIZ; Comment: Entered by DMERANZ1 - }
10/21/2019 COT - BULD - SWG Clearance Passed {Activity date: 10/21/2019; Status: Approved; Inspector: DMUNIZ; Comment: Entered by DMERANZ1 - }
10/21/2019 RSME - Mechanical Progress Passed {Activity date: 10/21/2019; Status: Approved; Inspector: DMUNIZ; Comment: Entered by DMERANZ1 - }
10/21/2019 COT - RSPL - Gas Pressure Test Passed {Activity date: 10/21/2019; Status: Approved; Inspector: DMUNIZ; Comment: Entered by DMERANZ1 - Clear Southwest Gas.}
10/23/2019 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed {Activity date: 10/23/2019; Status: Approved; Inspector: DMUNIZ; Comment: Entered by DMERANZ1 - } ; {Activity date: 10/21/2019; Status: Not ready for Inspection; Inspector: DMUNIZ; Comment: Entered by DMERANZ1 - }
10/23/2019 COT - LCBU - Framing Passed {Activity date: 10/23/2019; Status: Approved; Inspector: DMUNIZ; Comment: Entered by DMERANZ1 - } ; {Activity date: 10/21/2019; Status: Not ready for Inspection; Inspector: DMUNIZ; Comment: Entered by DMERANZ1 - Install Anchor bolts at sill plates where needed & for HTT4 in Master bath. Nail and shim H2.5s at Interior bearing points.}
10/23/2019 COT - LCPL - Plumbing Intermediate Passed {Activity date: 10/23/2019; Status: Approved; Inspector: DMUNIZ; Comment: Entered by DMERANZ1 - } ; {Activity date: 10/21/2019; Status: Not ready for Inspection; Inspector: DMUNIZ; Comment: Entered by DMERANZ1 - Provide DWV test on plumbing top out.}
11/01/2019 COT - HCBU - Interior Shear Bracing Passed {Activity date: 11/01/2019; Status: Approved; Inspector: DMUNIZ; Comment: Entered by DMERANZ1 - }
12/17/2019 COT - RSEL - Construction Power Passed {Activity date: 12/17/2019; Status: Approved; Inspector: WGALLAG1; Comment: Entered by DMERANZ1 - }
01/10/2020 PDSD Building Division - TEP PM Clearance Passed {Activity date: 01/10/2020; Status: Approved; Inspector: WGALLAG1; Comment: Entered by DMERANZ1 - CODE ECO}
01/21/2020 COT - RSME - Mechanical Final Passed {Activity date: 01/21/2020; Status: Approved; Inspector: DQUINN; Comment: Entered by DMERANZ1 - }
01/21/2020 COT - RSEL - Outdoor Lighting Passed {Activity date: 01/21/2020; Status: Approved; Inspector: DQUINN; Comment: Entered by DMERANZ1 - }
01/21/2020 COT - RSPL - Plumbing Final Passed {Activity date: 01/21/2020; Status: Approved; Inspector: DQUINN; Comment: Entered by DMERANZ1 - }
01/21/2020 COT - RSEL - Electrical Final Passed {Activity date: 01/21/2020; Status: Approved; Inspector: DQUINN; Comment: Entered by DMERANZ1 - }
04/09/2020 RSBU - Building Final Passed {Activity date: 04/09/2020; Status: Approved; Inspector: KEN; Comment: Entered by KKARSEN1 - Special Inspection Cert filed} ; {Activity date: 01/21/2020; Status: Partial Approval; Inspector: DQUINN; Comment: Entered by DMERANZ1 - APPROVED BY INSPECTOR, CLOSURE IS PENDING SPECIAL INSPECTION CERTIFICATE FOR POST TENSION SLAB}

Documents

File Name Document Type  
None DOCUMENTS VIEW
None CONSTRPLANS VIEW