Permit: T19CM04920
Permit Details
Status:
Expired
Type:
Residential Building - One or Two Family
Address:
2475 E CORTE DE FEDERICO
Address NEW:
2475 E CORTE DE FEDERICO
Apply Date:
07/10/2019
Applicant:
Sue Taylor
Description:
AFST204619 T19-M0010
Permit Reviews
Permit Number - T19CM04920
Permit Status: Expired
Permit Description: AFST204619 T19-M0010
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 07/10/2019 | RESIDENTIAL - BLDG-MODEL PLAN/ENGINE/WALK THRU | 07/10/2019 | COMPLETED |
| 10/10/2019 | REVISION - - 1ST | 10/10/2019 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T19CM04920
Permit Status: Expired
Permit Description: AFST204619 T19-M0010
Total Outstanding Activity Conditions - 3
| Date | Name |
|---|---|
| 07/10/2019 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
| 07/10/2019 | ROOF TRUSSES MUST BE APPROVED PRIOR TO FRAMING INSPECTION (P2I) |
| 07/10/2019 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. |
Completed Inspections
Permit Status: Expired
Permit Number: T19CM04920
Permit Description: AFST204619 T19-M0010
Total Completed Inspections - 24
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/12/2019 | COT - RSPL - Yard Water Line | Passed | {Activity date: 08/12/2019; Status: Approved; Inspector: RCHANDLER; Comment: Entered by DMERANZ1 - } | |
| 08/13/2019 | COT - RSPL - Sewer | Passed | {Activity date: 08/13/2019; Status: Approved; Inspector: DQUINN; Comment: Entered by DMERANZ1 - } ; {Activity date: 08/12/2019; Status: Correction Required; Inspector: RCHANDLER; Comment: Entered by DMERANZ1 - Provide bell hole for inspection at all joints to allow for 360 degree inspection.} | |
| 08/13/2019 | COT - RSPL - Rough Soil | Passed | {Activity date: 08/13/2019; Status: Approved; Inspector: DQUINN; Comment: Entered by DMERANZ1 - } ; {Activity date: 08/12/2019; Status: Correction Required; Inspector: RCHANDLER; Comment: Entered by DMERANZ1 - Provide bell hole for inspection at all joints to allow for 360 degree inspection.} | |
| 08/19/2019 | COT - RSEL - Grounding/Bonding | Passed | {Activity date: 08/19/2019; Status: Approved; Inspector: DQUINN; Comment: Entered by DMERANZ1 - } ; {Activity date: 08/16/2019; Status: Cancelled; Inspector: DQUINN; Comment: Entered by DMERANZ1 - } | |
| 08/19/2019 | COT - RSBU - Preslab | Passed | {Activity date: 08/19/2019; Status: Approved; Inspector: DQUINN; Comment: Entered by DMERANZ1 - } ; {Activity date: 08/16/2019; Status: Cancelled; Inspector: DQUINN; Comment: Entered by DMERANZ1 - } | |
| 08/19/2019 | COT - RSEL - Electrical Underground | Passed | {Activity date: 08/19/2019; Status: Approved; Inspector: DQUINN; Comment: Entered by DMERANZ1 - } ; {Activity date: 08/16/2019; Status: Cancelled; Inspector: DQUINN; Comment: Entered by DMERANZ1 - } | |
| 08/19/2019 | COT - RSBU - Excavation/Rebar/Zoning | Passed | {Activity date: 08/19/2019; Status: Approved; Inspector: DQUINN; Comment: Entered by DMERANZ1 - } ; {Activity date: 08/16/2019; Status: Cancelled; Inspector: DQUINN; Comment: Entered by DMERANZ1 - } | |
| 09/23/2019 | COT - RSBU - Roof Nailing | Passed | {Activity date: 09/23/2019; Status: Approved; Inspector: DQUINN; Comment: Entered by VFLORES1 - } | |
| 09/23/2019 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | {Activity date: 09/23/2019; Status: Approved; Inspector: DQUINN; Comment: Entered by VFLORES1 - } | |
| 10/02/2019 | RSPL - Plumbing Progress | Passed | {Activity date: 10/02/2019; Status: Approved; Inspector: JCLAXTON; Comment: Entered by DMERANZ1 - Verified sewer connection.} | |
| 10/31/2019 | PDSD Building Division - TEP PM Clearance | Passed | {Activity date: 10/31/2019; Status: Approved; Inspector: RCHANDLER; Comment: Entered by DMERANZ1 - CODE ECO} | |
| 10/31/2019 | COT - RSEL - Construction Power | Passed | {Activity date: 10/31/2019; Status: Approved; Inspector: RCHANDLER; Comment: Entered by DMERANZ1 - Clearance TEP eco. Note: No gas or water bond at this time.} | |
| 11/19/2019 | COT - LCBU - Framing | Passed | {Activity date: 11/19/2019; Status: Approved; Inspector: DQUINN; Comment: Entered by DMERANZ1 - } | |
| 11/19/2019 | COT - LCPL - Plumbing Intermediate | Passed | {Activity date: 11/19/2019; Status: Approved; Inspector: DQUINN; Comment: Entered by DMERANZ1 - } | |
| 11/19/2019 | RSME - Mechanical Progress | Passed | {Activity date: 11/19/2019; Status: Approved; Inspector: DQUINN; Comment: Entered by DMERANZ1 - } | |
| 11/21/2019 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | {Activity date: 11/21/2019; Status: Approved; Inspector: DQUINN; Comment: Entered by DMERANZ1 - } ; {Activity date: 11/19/2019; Status: Denied; Inspector: DQUINN; Comment: Entered by DMERANZ1 - Secure powder room toilet flange to floor. Install nailing boca plates on 3” abs top plate in garage and kitchen.Not a boca bang plate. Block between combustion/ relief in garage. Block kitchen Hvac duct boot in kitchen. No a/c in laundry?} |
|
| 11/21/2019 | COT - RSPL - Gas Pressure Test | Passed | {Activity date: 11/21/2019; Status: Approved; Inspector: DQUINN; Comment: Entered by DMERANZ1 - } ; {Activity date: 11/19/2019; Status: Partial Approval; Inspector: DQUINN; Comment: Entered by DMERANZ1 - Gas at 12.8 lbs. check tomorrow.} ; {Activity date: 10/17/2019; Status: Not ready for Inspection; Inspector: RCHANDLER; Comment: Entered by DMERANZ1 - No piping at this location, however I found some at 2464 E Calle De Lupe that is holding pressure and installed per approved plan.} ; {Activity date: 10/15/2019; Status: Not ready for Inspection; Inspector: RCHANDLER; Comment: Entered by DMERANZ1 - Work incomplete.} | |
| 12/05/2019 | COT - HCBU - Interior Shear Bracing | Passed | {Activity date: 12/05/2019; Status: Approved; Inspector: JCLAXTON; Comment: Entered by DMERANZ1 - Ok to proceed} | |
| 03/16/2020 | COT - RSPL - Plumbing Final | Passed | {Activity date: 03/16/2020; Status: Approved; Inspector: ESTEVENS; Comment: Entered by SFLORES2 - Southwest gas clearance required for gas meter .} ; {Activity date: 10/02/2019; Status: Partial Approval; Inspector: JCLAXTON; Comment: Entered by DMERANZ1 - Verified sewer connection.} ; {Activity date: 07/11/2019; Status: Prior to Final Inspectn; Inspector: GKOLSH; Comment: Entered by AVAUGHN1 - SWR_SIERRA VISTA ACRES N378' LOT 4 SFR - ISSUED WITH PCRWRD CONDITIONS: NO PHYSICAL CONNECTION TO THE PUBLIC SEWER SYSTEM UNTIL THE PUBLIC SEWER G-2019-003 IS ACCEPTED AND RELEASED BY PCRWRD - NO FINAL AND NO CERTIFICATE OF OCCUPANCY UNTIL THE PUBLIC SEWER G-2019-003 IS ACCEPTED AND RELEASED BY PCRWRD - ONE $4,188.00 CREDIT GIVEN FOR 3653 N TUCSON BOULEVARD PER PERMIT #PJ-9409 DATED 9/25/78 - USER FEES FROM 11/2/78 TO 5/2/19 (ON A WELL PER MELODY BURTON) - OK PER MARLA BERRY 5/17/19} |
|
| 03/16/2020 | COT - BULD - SWG Clearance | Passed | {Activity date: 03/16/2020; Status: Approved; Inspector: ESTEVENS; Comment: Entered by SFLORES2 - } | |
| 03/24/2020 | COT - RSME - Mechanical Final | Passed | {Activity date: 03/24/2020; Status: Approved; Inspector: MRAMBER; Comment: Entered by SFLORES2 - } ; {Activity date: 03/16/2020; Status: Partial Approval; Inspector: ESTEVENS; Comment: Entered by SFLORES2 - No ladder to access air handler.} | |
| 03/24/2020 | RSBU - Building Final | Passed | {Activity date: 03/24/2020; Status: Approved; Inspector: MRAMBER; Comment: Entered by SFLORES2 - } ; {Activity date: 03/16/2020; Status: Partial Approval; Inspector: ESTEVENS; Comment: Entered by SFLORES2 - Pending other inspections.} | |
| 03/24/2020 | COT - RSEL - Outdoor Lighting | Passed | {Activity date: 03/24/2020; Status: Approved; Inspector: MRAMBER; Comment: Entered by SFLORES2 - } | |
| 03/24/2020 | COT - RSEL - Electrical Final | Passed | {Activity date: 03/24/2020; Status: Approved; Inspector: MRAMBER; Comment: Entered by SFLORES2 - } ; {Activity date: 03/16/2020; Status: Partial Approval; Inspector: ESTEVENS; Comment: Entered by SFLORES2 - No GFCI on laundry, open neutral in front bedroom.} |