Permit: T19CM04397
Permit Details
Status:
Expired
Type:
Residential Building - One or Two Family
Address:
6878 E CORTE CASA ELEGANTE
Address NEW:
6878 E CORTE CASA ELEGANTE
Apply Date:
06/19/2019
Applicant:
Description:
SFR LEN400418 T18-M0080
Permit Reviews
Permit Number - T19CM04397
Permit Status: Expired
Permit Description: SFR LEN400418 T18-M0080
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 06/19/2019 | RESIDENTIAL - BLDG/ZONING-WALKTHRU | 06/20/2019 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T19CM04397
Permit Status: Expired
Permit Description: SFR LEN400418 T18-M0080
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 06/19/2019 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Conditions
Permit Number - T19CM04397
Permit Status: Expired
Permit Description: SFR LEN400418 T18-M0080
| Date | Description | Comments |
|---|---|---|
| 06/19/2019 | ROOF TRUSSES MUST BE APPROVED PRIOR TO FRAMING INSPECTION (P2I) | |
| 06/19/2019 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. |
Completed Inspections
Permit Status: Expired
Permit Number: T19CM04397
Permit Description: SFR LEN400418 T18-M0080
Total Completed Inspections - 23
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/10/2019 | COT - RSPL - Sewer | Passed | {Activity date: 07/10/2019; Status: Approved; Inspector: AKEINSORGE; Comment: Entered by DMERANZ1 - Ok to backfill } |
|
| 07/10/2019 | COT - RSPL - Rough Soil | Passed | {Activity date: 07/10/2019; Status: Approved; Inspector: AKEINSORGE; Comment: Entered by DMERANZ1 - Ok to backfill } |
|
| 07/17/2019 | COT - RSEL - Grounding/Bonding | Passed | {Activity date: 07/17/2019; Status: Approved; Inspector: DMUNIZ; Comment: Entered by DMERANZ1 - } | |
| 07/17/2019 | COT - RSBU - Preslab | Passed | {Activity date: 07/17/2019; Status: Approved; Inspector: DMUNIZ; Comment: Entered by DMERANZ1 - } | |
| 07/17/2019 | COT - RSEL - Electrical Underground | Passed | {Activity date: 07/17/2019; Status: Approved; Inspector: DMUNIZ; Comment: Entered by DMERANZ1 - } | |
| 07/17/2019 | COT - RSBU - Excavation/Rebar/Zoning | Passed | {Activity date: 07/17/2019; Status: Approved; Inspector: DMUNIZ; Comment: Entered by DMERANZ1 - } | |
| 08/13/2019 | COT - RSBU - Roof Nailing | Passed | {Activity date: 08/13/2019; Status: Approved; Inspector: AKLEINSORGE; Comment: Entered by DMERANZ1 - Extend mechanical truss brace above the island to last mechanical truss and need nailer under roof sheet in front bedroom to nail roof sheeting} | |
| 08/13/2019 | COT - RSPL - Yard Water Line | Passed | {Activity date: 08/13/2019; Status: Approved; Inspector: AKLEINSORGE; Comment: Entered by DMERANZ1 - } ; {Activity date: 07/10/2019; Status: Partial Approval; Inspector: AKEINSORGE; Comment: Entered by DMERANZ1 - Ok to backfill between meter box and riser, final approval once water meter is set and line is under test } |
|
| 08/13/2019 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | {Activity date: 08/13/2019; Status: Approved; Inspector: AKLEINSORGE; Comment: Entered by DMERANZ1 - } | |
| 09/06/2019 | PDSD Building Division - TEP PM Clearance | Passed | {Activity date: 09/06/2019; Status: Approved; Inspector: DMUNIZ; Comment: Entered by DMERANZ1 - CODE ECO} | |
| 09/06/2019 | COT - RSEL - Construction Power | Passed | {Activity date: 09/06/2019; Status: Approved; Inspector: DMUNIZ; Comment: Entered by DMERANZ1 - Clear TEP (ECO).} | |
| 09/12/2019 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | {Activity date: 09/12/2019; Status: Approved; Inspector: DMUNIZ; Comment: Entered by DMERANZ1 - } | |
| 09/12/2019 | COT - LCBU - Framing | Passed | {Activity date: 09/12/2019; Status: Approved; Inspector: DMUNIZ; Comment: Entered by DMERANZ1 - } | |
| 09/12/2019 | COT - LCPL - Plumbing Intermediate | Passed | {Activity date: 09/12/2019; Status: Approved; Inspector: DMUNIZ; Comment: Entered by DMERANZ1 - } | |
| 09/12/2019 | RSME - Mechanical Progress | Passed | {Activity date: 09/12/2019; Status: Approved; Inspector: DMUNIZ; Comment: Entered by DMERANZ1 - } | |
| 09/12/2019 | COT - RSPL - Gas Pressure Test | Passed | {Activity date: 09/12/2019; Status: Approved; Inspector: DMUNIZ; Comment: Entered by DMERANZ1 - Clear Southwest Gas.} | |
| 09/26/2019 | COT - HCBU - Interior Shear Bracing | Passed | {Activity date: 09/26/2019; Status: Approved; Inspector: DMUNIZ; Comment: Entered by DMERANZ1 - } | |
| 11/13/2019 | COT - BULD - SWG Clearance | Passed | {Activity date: 11/13/2019; Status: Approved; Inspector: DMUNIZ; Comment: Entered by DMERANZ1 - RESEND} ; {Activity date: 09/12/2019; Status: Approved; Inspector: DMUNIZ; Comment: Entered by DMERANZ1 - } | |
| 11/21/2019 | COT - RSME - Mechanical Final | Passed | {Activity date: 11/21/2019; Status: Approved; Inspector: DMUNIZ; Comment: Entered by DMERANZ1 - } | |
| 11/21/2019 | COT - RSEL - Outdoor Lighting | Passed | {Activity date: 11/21/2019; Status: Approved; Inspector: DMUNIZ; Comment: Entered by DMERANZ1 - } | |
| 11/21/2019 | COT - RSPL - Plumbing Final | Passed | {Activity date: 11/21/2019; Status: Approved; Inspector: DMUNIZ; Comment: Entered by DMERANZ1 - } | |
| 11/21/2019 | COT - RSEL - Electrical Final | Passed | {Activity date: 11/21/2019; Status: Approved; Inspector: DMUNIZ; Comment: Entered by DMERANZ1 - } | |
| 04/09/2020 | RSBU - Building Final | Passed | {Activity date: 04/09/2020; Status: Approved; Inspector: KEN; Comment: Entered by KKARSEN1 - Special Inspection Cert filed} ; {Activity date: 11/21/2019; Status: Partial Approval; Inspector: DMUNIZ; Comment: Entered by DMERANZ1 - APPROVED BY INSPECTOR, CLOSURE PENDING SPECIAL INSPECTION CERTIFICATE AND ROOF TRUSS CALCS} |